![Duerkopp Adler 975-1-5 Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/duerkopp-adler/975-1-5/975-1-5_service-instructions-manual_2538383057.webp)
8.
Maintenance
Caution Risk of Injury !
Turn the main switch off.
The maintenance work on the sewing unit may only be conducted with
the machine turned off !
The maintenance tasks to be conducted by the operating personnel on
the sewing unit daily or weekly ( cleaning and lubricating ) are
described in Part 1: Operating Instructions Chapter 7. They are
included in the following table only for the sake of completeness !
Work to be done
Operating Hours
8
40
160
500
Machine Head
Remove lint accumulations in the area of the needle plate, hook
and thread trimmer ........................................................... ......................
•
Check the oil level in the oilpan ........................................................... ....
•
Check the oil feed at the window ........................................................... ..
•
Check hook lubrication ........................................................... .................
•
Check the timing belt ........................................................... ...................
•
Drive Unit for the Machine Head and Guide Curve
Check the ventilator wheel on the motor ..................................................
•
Check the condition and tension of the V-belt ...........................................
•
Guide Curve
Lubricate the curve paths with liquid grease .............................................
•
Lubricate the roller ........................................................... .......................
•
Clamping Table
Clean the running surfaces of the clamping table with compressed air ......
•
Clean the ball elements with an oil-soaked rag .........................................
•
Check the play of the worm gear ........................................................... ...
•
Lubricate the curve paths of the guide curves with liquid grease ...............
•
Pneumatic System
Check the water level in the pressure regulator ........................................
•
Clean the filter insert in the maintenance unit ...........................................
•
Check the system for leaks ........................................................... ...........
•
57