4.8
Interior Slides
The interior slides 1 and 2 determine the clearance between the seam
and trim edge in the following seam segments.
Seam Segment
Element
Trim Edge
a
2 Interior slides-Swing table
b
2 Interior slides-Swing table
c
3 Inner forward slide
d
-
Position of the clamping table
e
1 Interior slides-Fixed table
f
1 Interior slides-Fixed table
In order that the interior slides, during their movement into the initial
position, do not pull the folded trim with them, the inner forward slide 3
in this phase must still be in the extended position. The inner forward
slide is thus brought into the initial position 2° later.
The clearance between seam and trim edge is:
a and b = 1 mm
f
= 1.5 mm
ATTENTION !
Scratches can occur on the interior slides if the folding device is
activated without cloth.
a
f
1
2
e
b
c
3
a
b
c
d
e
f
44