2.5 Stroke cylinder for the material
guide rail
Turn main switch off
- Risk of Injury -
A perfect laying-on of the material guide rail is
dependent on the setting of the stroke cylinder 1.
As described in 2.4, the stroke cylinder 1 must be
set vertically.
The lowering stroke should be so dimensioned that
the material guide rail just barely securely lays on
to the material slider bed.
A stroke cylinder 1 set too low worsens the laying
on of the material guide rail.
The material guide rail, which is pretensioned
along its whole length, could lift in the middle.
–
Loosen screw 9.
–
Set the height of the stroke cylinder 1
appropriately.
–
Tighten screw 9.
1
9
7
Содержание 744-122