Adjusting
a) The trimmer point 4 should not cover the stitch
hole in the throat plate. This applies especially
in the curve of the rail. (Danger of breaking the
needle.)
The edge 3 of the trimmer point should lie to
the left at the circular recess in the material
slider bed as shown in the illustration.
–
Turn main switch off.
–
Manually pull the transport carriage about half
of its length to the left. The trimmer guide roller
13 must be in a straight part of the rail.
–
Loosen screw 9. Set the shaft 11 in the holder 7
so that the bezel 8 can still be seen.
–
Tighten screw 9 until it touches surface.
–
With the trimmer swing-out and lever 5 at the
right rest, place the block 6 close on the
holder 7.
–
When tightening the screw 9 take care that the
plate 10 remains horizontal.
If the setting of the trimmer point has not been
achieved, then the whole trimmer is to be removed
after screw 9 has been loosened.
Loosen screws 12 and set plate 10 accordingly.
When inserting the trimmer again bring the block 6
to rest on the holder 7.