background image

Contatto

ModDALI

Correct disposal of the product (waste electrical & electronic 
equipment)

(Applicable in the European Union and other European
countries with separate collection systems). This mark-
ing on the product, accessories or documentation indi-
cates   that   the   product   and   its   electronic   accessories
should not be disposed of with other household waste

at the end of their working life. To prevent possible harm to the en-
vironment   or   human   health   from   uncontrolled   waste   disposal,
please separate these items from other types of waste and recycle
them responsibly to promote the sustainable reuse of material re-
sources. Household users should contact either the retailer where
they purchased this product, or their local government office, for
details of where and how they can take these items for environ-
mentally safe recycling. Business users should contact their suppli-
er and check the terms and conditions of the purchase contract.
Adequate   disposal   of   the   decommissioned   equipment   for   recy-
cling, treatment and environmentally compatible disposal contrib-
utes in preventing potentially negative effects on the environment
and health and promotes the reuse and/or recycling of equipment
materials. Abusive product disposal by the user is punishable by
law with administrative sanctions.

Installation and use restrictions 
Standards and regulations

The design and the setting up of electrical systems must be per-
formed according to the relevant standards, guidelines, specifica-
tions   and   regulations   of   the   relevant   country.   The   installation,
configuration and programming of the devices must be carried out
by trained personnel.
The installation and the wiring of the 

Contatto

 bus line and the re-

lated devices must be performed according to the recommenda-
tions of the manufacturers (reported on the specific data sheet of
the product) and according to the applicable standards.
All the relevant safety regulations, e.g. accident prevention regula-
tions, law on technical work equipment, must also be observed.

Safety instructions

Protect the unit against moisture, dirt and any kind of damage dur-
ing transport, storage and operation.
Do not operate the unit outside the specified technical data.
Never open the housing. If not otherwise specified, install in closed
housing (e.g. distribution cabinet).
Earth the unit at the terminals provided, if existing, for this purpose.
Do not obstruct cooling of the units.

Setting up

The physical address must be assigned with the specific program-
mer and the setting of parameters (if any) must be performed by
the specific configuration softwares; for more details refer to the
specific data sheet of the product. For the first installation of the
device, generally and  unless  otherwise specified on the specific
data   sheet   of   the   product,   proceed   according   to   the   following
guidelines:

Check that any voltage supplying the plant has been removed

Assign the address to module (if any)

Install and wire the device according to the schematic diagrams
on the specific data sheet of the product

Only then switch on the 230Vac supplying the bus power supply
and the other related circuits

Applied standards

The devices belonging to  

Contatto

  line comply with the essential

requirements of the following directives:
2014/30/UE (EMC)
2014/35/UE (Low Voltage)
2011/65/UE (RoHS)

Note

Technical characteristics and this data sheet are subject to change
without notice.

DUEMMEGI

 s.r.l. - Via Longhena, 4 - 20139 MILANO

Tel. 02/57300377 - Fax 02/55213686 – 

www.duemmegi.it

Rel.: 2.4 October 2017

Page 9 of 9

Содержание CONTATTO ModDALI

Страница 1: ...ALI module provides a 5 way terminal blocks for the connection to Contatto bus a 2 way terminal block for the supply voltage of DALI section and a 9 way terminal blocks for the connection to the 4 DAL...

Страница 2: ...llowing table gives some rules for the MINIMUM ca ble section As said above no special cables are required for the 4 DALI lines provided that they have double insula tion In any case the distance betw...

Страница 3: ...ballast will not be under stood the value 129 will be reported If the brightness level of each ballast on each DALI line is required by the application a script for MCP is available for this purpose c...

Страница 4: ...t level The code 113 enable again the polling the current status of the polling is re ported bu the point 11 of the input channel if enabled At the module power up or after a reset the polling is alwa...

Страница 5: ...ting parameters of each DALI channel and to perform some diagnostic functions The setting up is performed via the Contatto bus and MCP through a specific configuration panel which can be opened select...

Страница 6: ...tion of the mapping procedure pressing the but ton Start will take place only for the ballasts selected by the related checkbox A timer icon will inform that the oper ation is running At the end of th...

Страница 7: ...ake in account that it is not pos sible to read from ModDALI module the current settings of the groups therefore it is strongly recommended to save them into a file for future modifications Global Set...

Страница 8: ...ry each scenery will be a file Commands This tab provides a several commands belonging to DALI protocol this section is addressed to highly qualified staff so it is recommended not to use it if you ar...

Страница 9: ...d the wiring of the Contatto bus line and the re lated devices must be performed according to the recommenda tions of the manufacturers reported on the specific data sheet of the product and according...

Отзывы: