the passage.
Voluntarily interrupting their range you can keep the gate open.

The photocells must be installed to a maximum distance of 10 m between them, perfectly aligned. It is advisable 
to position the photocell receiver so that it can not be disturbed by sunlight.

The photocells have a minimum lateral dimensions (only 2cm) and do not need to be recessed into the wall.
Must be fixed to the wall or on special columns and are suitable for outdoor use.
It is advisable to seal the outlet passage of the cables with silicone. see FIG.19 -22
Power supply: 12-24 V - d.c / a.c.

Connect to the electronic card following the wiring diagram of:
FIG.16 (photocell LASER Model SW7012 or 7012 ) for versions with card and CTH43
FIG.17 / A ( photocell model SW7120 or LASER7120 ) versions for use with card CTH46 powered by solar panel
FIG.17B (photocell LASER Model SW7012 or 7012 ) for versions with card CTH46 use on AC 230V -110V

15.5

 KEYBoARD RADIo SW6500 - TASTY6700

Keyboard is a one channel rolling code radio 
remote control 
Without connecting cables used to activate the automation typing on a 4-digit personal code.
A rolling code signal will be transmitted to the equipment that will open the gate.
Can be installed inside and outside. Install in Max.10m from the control unit of the automation.
The device is outdoor but it is recommended if possible to install the keyboard in place protected from rain.
It is recommended to seal well the back of the keyboard before fixing it to the wall.

The keyboard comes with a standard code = 1111.
This code must be replaced with a personal code. Once you register your personal code the keyboard is 
synchronized to the electronic automation in the same way in which you store the codes of other remote controls 
(see paragraph 12).

Warning

: Write down your personal code and keep it in a safe place if you would record a code and if they forget 

the figures, it would not be possible, for security reasons, reset the keyboard less than a new schedule at our 
service center on resulting cost of intervention.

noTE

: If you type a wrong code 3 times, the keypad will enter in protection mode for 10 minutes. Wait 10 minutes 

and enter the correct code.

WARnIng
1 - To AMEnD THE CoDE STAnDARD WITH A PERSonAL CoDE:

a) enter the standard code 1111 + push button  3 + New 4-digit code + ENTER button at the bottom center.
   the keypad beeps to confirm the operation.
  This deletes the standard code 1111.

Attention:

 Before storing your personal code on the keyboard  write it down and keep it in a safe place.

2 - To SEnD AnD SToRE THE RADIo SIgnAL automaton

a) on the central electronic automation: press P1
b) on the keypad dial the 4-digit personal code previously ENTER button at the bottom center.

Attention: The EnTER key must be pressed a few seconds.

The keypad will beep to confirm the operation. The red LED on the electronic board of your device  will flash to 
indicate the code has been stored.
The keyboard is synchronized with the central control automation. To operate the gate repeat step b )

3 - To REPLACE A PERSonALIZED CoDE:

a) enter the 4-digit personal code +
  push button 4+ the new 4-digit code + ENTER button at the bottom center.
  the keypad beeps to confirm the operation .

4 - To ADD A PERSonALIZED CoDE (without erasing the previously stored personal code):

a) enter the 4-digit personal code + 
  push button  3 + the new 4-digit code + ENTER button at the bottom center.
  the keypad beeps to confirm the operation.

Содержание Manual Slide

Страница 1: ...RICANCELLI SCORREVOLI OUVRE PORTAIL COULISSANT SLIDING GATE OPENER AUTOMATIZACIONES PARA PUERSTAS CORREDERAS SCHIEBETORANTRIEB H O M E H O M E DU CATI a u t o m a t i o n a u t o m a t i o n MANUALE S...

Страница 2: ...l optional optional SW7120 optional optional optional optional optional optional Fash 7012 optional optional optional optional 1 1 Fash 7120 optional optional optional optional optional optional optio...

Страница 3: ...600kg 8m CTH43 no SL 843 230V 12V 200 800kg 12m CTH43 no SL 640 230V BATT SOL 12V 140 600kg 8m CTH46 yes SL 840 230V BATT SOL 12V 200 800kg 12m CTH46 yes Table 01 ON OFF DUCATI HOME SOLAR OPION 230 V...

Страница 4: ...4 FIG 04 A FIG 04 B FIG 05 A FIG 05 B LOCK UNLOCK FIG 06 FIG 05 C OPTIONAL PLAK 8700 RED BLUE BLUE RED...

Страница 5: ...5 FIG 09 FIG 7 C FIG 7 D 105mm 0 1 33 mm 0 2 Portail FIG 7 A 1 2 mm max FIG 11 R M FIG 10 R M FIG 12 R M R M A B FIG 7 B FIG 08...

Страница 6: ...6 230 V FUSE T0 8A FIG 13 FIG 14 A FIG 14 B FIG 15 A FIG 15 B CTH 43 CTH 43 CTH 46 CTH 46 N L...

Страница 7: ...7 START TRANSFORMER 0 BLACK 12 V YELLOW FUSE T 0 8A C NO 24V 0 sec 100 sec C M BAT optional battery changer Battery PHOTOCELLS SW 7012 12 V 10W MAX 230V 0 100 RX TX FIG 16 CTH 43 N L...

Страница 8: ...8 PED START TRANSFORMER 0 BLACK 12 V YELLOW FUSE T0 8A PHOTOCELLS SW 7120 12 V 10W MAX 0 100 RX TX FUSE T0 8A FIG 17 A CTH 46...

Страница 9: ...9 TERMINAL PHOTOCELLS SW7012 CTH 46 FCT RX TX FIG 17 B FIG 18 FIG 22 FIG 21 FIG 20 FIG 19 FIG 23 FIG 24...

Страница 10: ...ll local electrical and building codes During installation Ensure your personal safety Never wear watches rings or loose clothing while installing or servicing the opening system They could get caught...

Страница 11: ...hether moving open closed or stopped Never permit children to play with the door opener s remote control buttons or transmitters and do not allow children to use them to operate the door opener Always...

Страница 12: ...k the fixing position of the motor to the ground see Figure 2 4 7C 10 11 Provide ducts for cables and related accessories cable mm 0 25 mm DANGER WARNING The connection of the high voltage 230V 50Hz o...

Страница 13: ...THE RACK Proceed as in fig 9 inserting the two media magnet along the rack through the interlocking system Slide the two supports up to min 10 cm from the ends of the gate See fig 12 for the moment th...

Страница 14: ...f the final position of the end stops proceed in two stages Before final fixing place the magnets momentarily to 10 cm before the desired final stop position of the gate in order to make sure that the...

Страница 15: ...mer Power must be fully rotated CLOCKWISE setting power to the maximum FIG 16 17 A ATTENTION ALL ADJUSTMENTS SHOULD BE MADE TO THE GATE CLOSED The regulations will be effective only in the next cycle...

Страница 16: ...r versions with electonic board CTH46 15 3 Key switch SW5000 KEY5000 The key switch is a wired device that allows you to operate your door The contact is NO Turnthe key to activate the command Connect...

Страница 17: ...code the keyboard is synchronized to the electronic automation in the same way in which you store the codes of other remote controls see paragraph 12 Warning Write down your personal code and keep it...

Страница 18: ...keyboard is in the process of flashing The keypad beeps to confirm the operation CAUTION After this operation the keyboard will resume the standard code 1111 but you can not use it to control the gat...

Страница 19: ...ttere in buono stato il cancello e la struttura prima di procedere all installazione dell automatismo onde evitare qualsiasi rischio di danni ferite gravi o morte Prima dell installazione riparate o s...

Страница 20: ...oni o decesso Fissare in prossimit della porta automatizzata un pannello visibile e permanente di avviso e segnalazione della presenza di un sistema automatizzato Senza un sistema di sicurezza special...

Страница 21: ...ATTENZIONE PERICOLO Il cancello deve avere dei fine corsa meccanici di fermo con battuta di arresto in caso contrario il cancello pericoloso e potrebbe deragliare dal binario causando un grave rischi...

Страница 22: ...er accedere all interno della propriet 8 FISSAGGIO DELLA CREMAGLIERA La cremagliera mod 8602 fornita in spezzoni da 50cm con un sistema ad incastro a coda di rondine FIG 7 B Ogni spezzone va singolarm...

Страница 23: ...di collegamento alla batteria sono gi forniti con la scheda Attenzione rispettare le polarit dei cavi di collegamento alla batteria Attenzione la batteria va collegata a massimo livello di carica Prim...

Страница 24: ...gni tasto del radiocomando corrisponde ad 1 canale Se si necessita pi capacit di memoria disponibile una ricevente esterna optional a 4 canali modello RIXY 6040 6040 Rol con una capacit di 40 codici o...

Страница 25: ...cezione in fase di chiusura gi in corso ATTENZIONE ATTENZIONE TUTTE LE REGOLAZIONI DOVRANNO ESSERE EFFETTUATE A CANCELLO CHIUSO e saranno efficaci solo nel ciclo successivo 15 ACCESSORI 15 1 Lampeggia...

Страница 26: ...o normative per pi specifiche Le fotocellule non sono dunque pi obbligatorie in quanto la loro efficacia limitata Le fotocellule sono utili per poter comandare la riapertura del cancello mentre lo ste...

Страница 27: ...il cancello ripetere il punto b 3 PER SOSTITUIRE UN CODICE PERSONALIZZATO a digitare il codice personale a 4 cifre il tasto 4 il nuovo codice a 4 cifre il tasto ENTER in basso al centro la tastiera em...

Отзывы: