24
TROUBLESHOOTING
Problem
Cause
Solution
Generator is running, but does not
supply power.
1. DC Circuit Breaker is “OFF”
2. Green AC Pilot Light Indicator is off.
3. Poor connection
4. Defective cord set
5. Connected device is faulty
6. Fault in generator
1. Turn DC Circuit Breaker “ON”
2. Stop engine and restart.
3. Check and repair
4. Check and repair
5. Connect a device that is working
properly
6. Contact service department
Engine runs good without load but
bogs down when loads are connected
1. Short circuit in connected device
2. Generator is overloaded
4. Engine speed is too slow
5. Short circuit in generator
1. Disconnect device
2. See pg 17 “Don’t overload
generator”
4. Contact service department
5. Contact service department
Engine will not start, shuts down during
operation, or starts and runs rough.
1. 3 in 1 switch set to “OFF”
4. Out of fuel or Stale fuel
5. Spark plug wire disconnected from
spark plug
6. Bad spark plug
7. Water in fuel
8. Overchocking
9. Low oil level
11. Faulty ignition
1. Turn switch to “CHOKE” then pull
recoil starter.
4. Replace fuel
5. Reconnect spark plug wire
6. Clean or replace spark plug
7. Drain fuel tank and replace fuel
8. Turn off choke
9. Add oil level.
10. Wait 5 minutes and recrank engine
11. Contact o
ur
dealer
Engine lacks power
1. Generator is overloaded
4. Engine needs servicing
1. See pg 17 “Don’t overload
generator”
4. Contact service department
Engine “hunts” or falters
1. Choke was removed too soon
3. Carburetor is running too rich or too
lean
1. Move to choke until engine runs
evenly
3. Contact service department
Содержание D2000iS
Страница 26: ...26 WIRING DIAGRAM W W P 2 1 3 4 ...
Страница 27: ...27 WIRING DIAGRAM P 1 2 3 4 ...