Truncate Zero 

When the barcode leading have “0”, you can configured this function to 

truncate all leading "0" of barcode. 

 

Example: Barcode "00054321"=>Output "54321" 

Truncate Zero for UPC-A 

Enable 

*Disable 

Truncate Zero for EAN-13 

Enable 

*Disable 

Truncate Zero for Code-39 

Enable 

*Disable 

Truncate Zero for UPC-E 

Enable 

*Disable 

Truncate Zero for EAN-8 

Enable 

*Disable 

Truncate Zero for Codabar / NW7 

Enable 

*Disable 

Truncate Zero for Code-128 

Enable 

*Disable 

  82 

  81 

Содержание DS-800

Страница 1: ...DS 800 BT Pocket size Wireless Scanner User s Manual...

Страница 2: ...pe 17 Transmission Gap 18 Transmission Delay 19 Timeout 20 Keyboard Layout Setting 21 Bluetooth HID Dongle Keyboard Layout Setting 22 Virtual COM Type 23 Time out 23 Transmission Gap 24 Transmission D...

Страница 3: ...t Format Settings 69 Transmission Preamble 69 Transmission Postamble 69 Preamble Data 70 Postamble Data 71 Prefix Suffix 72 Prefix Data 72 Suffix Data 73 Code ID Sub Code ID 74 Code ID Setting 74 Wait...

Страница 4: ...ooth devices Mode 1 Econnect Bluetooth dongle Mode I Mode 2 HID Mode For third party Bluetooth devices Mode 3 iPad OSK MODE Mode selection code 4 Econnect Bluetooth dongle Mode II Mode 5 OK BT Local n...

Страница 5: ...ode OK End Set Pin Code to 5678 A Scan BT Module Enter Barcode B Scan Pin Code Barcode C Scan parameters from Hexadecimal Decimal table 5 6 7 8 OK Set Pin Code value to 5678 D Scan End Barcode Bluetoo...

Страница 6: ...Setting Enter Header Transmission Disabel Enabel Date Time Transmission Disabel Enabel Reject Same End Disabel Enabel Good Read Beep Disabel Enabel Good Read Vibrator Disabel Enabel Time Format hh mm...

Страница 7: ...time time gap setting in between each barcode data sending to PC 1 Enter 2 Ext Transmission Delay barcode 3 Scan parameters from Hexadecimal Decimal table Range 0 250 0 2 5sec 4 OK 5 End Lamp Off Del...

Страница 8: ...transmission must be enabled 1 Enter 2 Separator barcode 3 Scan parameters from Hexadecimal Decimal table Max 1digit 4 OK 5 End BT List Enter List User can simply understand their Bluetooth parameter...

Страница 9: ...me barcode 3 Scan parameters from Hexadecimal Decimal table Range 0 255 0 42Min 30sec 4 OK 5 End Standby Time This configuration enables the time configuration for the main power switching off after s...

Страница 10: ...be active This function is particular useful for some applications which host PC takes longer response time 1 Enter 2 Timeout barcode 3 Scan parameters from Hexadecimal Decimal table Range 0 99 0 99s...

Страница 11: ...lock On Transmission Gap 1 Enter 2 Transmission gap barcode 3 Scan parameters from Hexadecimal Decimal table Range 0 250 0 0 25sec This is the delay time setting between each barcode data characters I...

Страница 12: ...ecimal table Range 0 250 0 0 25sec 4 OK 5 End Timeout The timeout setting for the handshaking acknowledgment from host PC if scanner did not receive acknowledgement from the host PC the warning sound...

Страница 13: ...Enter Enter End End Keyboard Layout Setting US UK JP FR GR IT SP PO Bluetooth HID Dongle Keyboard Layout Setting US UK JP FR GR IT SP PO 22 21...

Страница 14: ...on gap barcode 3 Scan parameters from Hexadecimal Decimal table Range 0 250 0 0 25sec 4 OK 5 End Timeout The timeout setting for the handshaking acknowledgment from host PC if scanner did not receive...

Страница 15: ...ming between each barcode data scanned 1 Enter 2 Transmission Delay barcode 3 Scan parameters from Hexadecimal Decimal table Range 0 250 0 0 25sec 4 OK 5 End System Control Power On Music Enabel Disab...

Страница 16: ...the symbology of the barcode ID This configuration enables to display the Code ID or Sub Code ID Code ID Position After Before When Transmission Code ID is Enable user can configure the output positio...

Страница 17: ...sound 2 Beep Volume barcode 3 Scan parameters from Hexadecimal Decimal table Range 1 10 4 OK 5 End Beep Tone Beep Tone configuration enables to configure the frequency of beep sound 1 Enter 2 Beep Ton...

Страница 18: ...parameters from Hexadecimal Decimal table Range 0 250 0 2 5Sec 4 OK 5 End This function enables to set the duration time to turn off the main power of the scanner after scanning LED turns off 1 Enter...

Страница 19: ...imal Decimal table Range 0 250 0 2 5Sec 2 LED OFF Delay barcode 4 OK 5 End This enables to configure the duration time for scanning LED power off the scanning LED will automatically turn off if durati...

Страница 20: ...without any delay time 1 Enter 2 Good Read Time barcode 3 Scan parameters from Hexadecimal Decimal table Range 0 250 0 25sec 4 OK 5 End This configuration enables to set the duration of scanner confi...

Страница 21: ...r 3 Scan parameters from Hexadecimal Decimal table Range 0 250 0 2 5sec 2 Vibrator OFF Delay barcode 4 OK 5 End Vibrator OFF Delay Double Confirm This option enables the scanner to double confirm the...

Страница 22: ...Enter 2 Global Min length barcode 3 Scan parameters from Hexadecimal Decimal table Range 0 64 4 OK 5 End Global Max Length This function enables to set the maximum barcode length if the barcode length...

Страница 23: ...stamp the default format is YYMMDDHHMM 1 Enter 2 Set Data time barcode 3 Scan Decimal Barcode 1 2 0 8 3 0 1 3 3 0 OK as 2012 8 30 13 30 4 OK 5 End Symbology Settings UPC A Enter End Read Enabel Disab...

Страница 24: ...End End Enter Enter Wait Add on Enable Desable Transmission Checksum Enable Desable UPC E Read Enable Desable Wait Add on Enable Desable Add on Type None Add on 5 Add on 2 Add on 2 5 44 43...

Страница 25: ...Enter Enter End End Expansion Enable Desable Transmission Checksum Enable Desable EAN 13 Read Enable Desable Wait Add on Enable Desable Add on Type None Add on 5 Add on 2 Add on 2 5 45 46...

Страница 26: ...Enter Enter End End ISBN ISSN Conversion Enable Disable Transmission Checksum Enable Disable EAN 8 Read Enable Desable Wait Add on Enable Desable Add on Type None Add on 5 Add on 2 Add on 2 5 48 47...

Страница 27: ...Enter Enter End End Expansion Enable Disable Transmission Checksum Enable Disable Code 39 Read Enable Disable Type Standard Full ACSII Code 32 Translation None Code 32 with A Code 32 49 50...

Страница 28: ...tart End Enable Disable Checksum Verification Enable Disable Transmission Checksum Enable Disable Codabar NW7 Read Enable Disable Start End Symbol types ABCD ABCD ABCD TN E abcd abcd abcd tn e Same St...

Страница 29: ...n Start End Enable Disable Checksum Verification Enable Disable Transmission Checksum Enable Disable Code 128 Read Enable Disable Type Standard UCC 128 Checksum Verification Enable Disable Transmissio...

Страница 30: ...lue is not configured Null will refers to ASCII table for related setting 1 Enter 2 Connection data barcode 3 Scan Hexadecimal barcode table 4 1 4 2 OK means set Connection data value to AB please ref...

Страница 31: ...ustrial 2 of 5 Read Enable Disable Checksum Verification Enable Disable Transmission Checksum Enable Disable Matrix 2 of 5 Read Enable Disable Checksum Verification Enable Disable Transmission Checksu...

Страница 32: ...End Code 93 Read Enable Disable Transmission Checksum Enable Disable Checksum Verification Disable Two One Code 11 Read Enable Disable Transmission Checksum Enable Disable Checksum Verification Disabl...

Страница 33: ...lessey Read Enable Disable Transmission Checksum Enable Disable Checksum Verification Disable Mod 10 10 Mod 11 10 Mod 10 UK Plessey Read Enable Disable Verify Checksum Enable Disable Transmission Chec...

Страница 34: ...e Checksum Verification Enable Disable Type Numeric Auto switching ASCII Transmission Checksum Enable Disable RSS GS1 DataBar 14 Read Enable Disable Code Mark Enable Disable Application ID Enable Disa...

Страница 35: ...Enable Disable Code Mark Enable Disable Application ID Enable Disable Transmission Checksum Enable Disable RSS GS1 DataBar 14 Stack Read Enable Disable Code Mark Enable Disable Application ID Enable D...

Страница 36: ...ble Disable Code Mark Enable Disable Application ID Enable Disable Transmission Checksum Enable Disable RSS GS1 DataBar Expansion Stack Read Enable Disable Code Mark Enable Disable Application ID Enab...

Страница 37: ...mble Enable Disable Preamble Data There is control digits can be programmed as Preamble It will be appended automatically when each barcode is decoded The string of Preamble data will be before the ba...

Страница 38: ...le data will be behind the barcode data 1 Enter 2 Postamble data barcode 3 Scan Hexadecimal Barcode Max 8 digits 4 OK 5 End Prefix Suffix Prefix Data Appending characters behind the preamble data and...

Страница 39: ...flow chart 1 Enter 2 Suffix data barcode 3 Scan Hexadecimal Barcode Max 8 digits 4 OK 5 End Code ID Sub Code ID Code ID Setting Code ID for UPC A Code ID for EAN 13 Code ID for Code 39 Code ID for Co...

Страница 40: ...Plessey Wait Add On Count This setting is used for WPC add on code such as UPC A UPC E EAN 13 and EAN 8 The WPC code must be decoded first then Add on code Add on code may not be decoded with WPC at t...

Страница 41: ...al table D Scan OK barcode E Scan End barcode Min Length for Code 39 Min Length for Code 128 Min Length for Industrial 2 of 5 Min Length for Code 93 Min Length for MSI Plessey Min Length for Telepen M...

Страница 42: ...barcode E Scan End barcode Max Length for Code 39 Max Length for Code 128 Max Length for Industrial 2 of 5 Max Length for Code 93 Max Length for MSI Plessey Max Length for Telepen Max Length for Telep...

Страница 43: ...ode Example Barcode 00054321 Output 54321 Truncate Zero for UPC A Enable Disable Truncate Zero for EAN 13 Enable Disable Truncate Zero for Code 39 Enable Disable Truncate Zero for UPC E Enable Disable...

Страница 44: ...93 Enable Disable Truncate Zero for MSI Plessey Enable Disable Truncate Zero for Interleaved 2 of 5 Enable Disable Truncate Zero for Matrix 2 of 5 Enable Disable Truncate Zero for Code 11 Enable Disab...

Страница 45: ...ncated when these values are set to non zero It will be output nothing except beeps if the truncate value is more than barcode data digits or overlap with the Ending The maximum value of truncate digi...

Страница 46: ...for Interleaved 2 of 5 Truncate leading for Matrix 2 of 5 Truncate leading for Code 11 Truncate leading for UK Plessey Truncate leading for Telepen Truncate leading for RSS GS1 DataBar Limited Trunca...

Страница 47: ...A Scan Enter barcode B Scan Truncate ENd barcode C Scan parameters from Hexadecimal decimal table D Scan OK barcode E Scan End barcode Truncate Ending for UPC A Truncate Ending for EAN 13 Truncate End...

Страница 48: ...r Insert 0 Position When adding data to the barcode data insert position and insert data function must be configured If the insert position is configured as 0 the character will insert in the front of...

Страница 49: ...aved 2 of 5 Insert 0 Position for Matrix 2 of 5 Insert 0 Position for Code 11 Insert 0 Position for MSI Plessey Insert 0 Position for Telepen Insert 0 Position for RSS GS1 DataBar Limited Insert 0 Pos...

Страница 50: ...ure A Scan Enter barcode B Scan Insert 1 Position barcode C Scan parameters from Hexadecimal decimal table D Scan OK barcode Insert 1 Position for UPC A Insert 1 Position for EAN 13 Insert 1 Position...

Страница 51: ...DataBar Expansion Stack Insert 0 Data This function can append one or two characters into the barcode data But please make sure the value of insert position can not be greater than the length of barco...

Страница 52: ...Data for Interleaved 2 of 5 Insert 0 Data for Matrix 2 of 5 Insert 0 Data for Code 11 Insert 0 Data for UK Plessey Insert 0 Data for Telepen Insert 0 Data for RSS GS1 DataBar Limited Insert 0 Data for...

Страница 53: ...t 1 data barcode C Scan parameters from Hexadecimal decimal table D Scan OK barcode E Scan End barcode Insert 1 Data for UPC A Insert 1 Data for EAN 13 Insert 1 Data for Code 39 Insert 1 Data for Code...

Страница 54: ...Data for RSS GS1 DataBar Limited Insert 1 Data for RSS GS1 DataBar Expansion Insert 1 Data for RSS GS1 DataBar 14 Insert 1 Data for RSS GS1 DataBar 14 Stack Insert 1 Data for RSS GS1 DataBar Expansion...

Страница 55: ...Appendix ASCII Code Table Appendix ASCII Code Table 106 105...

Страница 56: ......

Отзывы: