Troubleshooting
Problem
Cause
Action
Unit will not turn on
(no power)
Yellow wire not connected or
incorrect voltage Red wire not
connected or incorrect voltage
Check connections for
proper voltage (11~16VDC)
Black wire not connected
Check connection to ground
Fuse blown
Replace fuse
Unit has power
(but no sound)
Speaker wires not connected
Check connections at
speakers
One or more speaker wires
touching each other or touching
chassis ground
Insulate all bare speaker
wires from each other and
chassis ground
Unit blows fuses
Yellow or red wire touching chassis
ground
Check for pinched wire
Speaker wires touching chassis
ground
Check for pinched wire
Incorrect fuse rating
Use fuse with correct rating
NO SUPPORT
appears on display
An invalid ID3 tag version is
present
Version 1.0 to 2.4 ID3 tags
are supported.
An ID3 tag character is not
supported
Only ASCII characters are
supported.
NO FILE appears
on display
Selected file is not available in
direct or alphanumeric search
modes
Repeat search using valid
parameters
PROTECT appears
on display
The WMA file is copy-protected by
DRM
(Digital Rights Management)
Write disc using WMA files
that are not copy-protected