2
Cuts Off
Do not try to send too loud a signal down the
telephone line otherwise this will be interpreted by the
microprocessor as a disconnect signal. If the receive
sound crackles or cuts off, reduce the output level
(VR1) until a clear sound is received. If you have been
connected for around three hours and then the
TDS1S/R cuts off, check that the three hour timer link
(J17) is disabled (out).
3
Too Quiet
There is a limit to how loud the signal is that can be
sent down a telephone line. If the received sound is too
quiet, the user will need an amplified telephone or
better, a hands free telephone with volume control.
Some models are louder than others so ask for a
demonstration.
4
No Connection The TDS1 S/R seems to be working in MANual mode
but won’t answer calls in AUTOmatic. Check that the
telephone line works and that you are dialing the right
number. Plug an ordinary telephone into the line jack
and test the line. If you can make and receive calls,
check the telephone lead between TDS1 S/R and
telephone socket. There are two telephone line fuses
within the TDS1 S/R. Disconnect the telephone line and
test FS1 and FS2.
5
No Audio
Check all the audio wiring for continuity. Ensure the
audio signal is applied between XLR pins 2 and 3.
6
Storm
There was a storm and now the TDS1 S/R does not
work. Return to base for repair and check.
7
Erratic
After connecting the facilities wiring, the TDS1 S/R
becomes unreliable. Could be faulty wiring (intermittent
joints or short circuits). Or the wiring could run close to
a source of electrical interference eg thyrister lighting -
re-route the cable.
8
Remote
Remote LED doesn’t work - Reverse the connections.
WARRANTY
The TDS1 S/R is guaranteed for a period of 1 year from the date of purchase
provided that it has been used in accordance with all these instructions. This
warranty specifically does NOT cover damage by lightning or user abuse and is
on condition that the unit is returned by prior agreement, to the supplier. Repair
or replacement is at the discretion of the supplier under the terms of this
warranty.
In the unlikely event that your TDS1 S/R fails, please contact the supplier for a
return address. When returning a unit, use the original packaging, be sure to
include a return address and contact point, and include a brief description of the
problem. We will provide a repair estimate if asked in advance.