![DTS SMS-2K-1 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/dts/sms-2k-1/sms-2k-1_maintenance-manual_2536177021.webp)
SMS-2K-1 Digital Cinema Server Maintenance Manual
Version 1.0
5.1.5 Lid Closing
When the previous steps are completed, the Digital Cinema Server lid can be closed by sliding it
from the rear panel to the front side – Make sure there are no wires caught by the lid.
Slide the cover to
the front side of
the chassis
Figure 23: Digital Cinema Server - Lid Closing
Tighten the 6 black screws that were removed at the beginning of the procedure, as presented
below:
Rear panel screws
side screws
side screws
Figure 24: Digital Cinema Server - Lid Screws
Then the unit can be put back into its rack – if any – and connected to power.
Note
: You might have to reconnect all the cables that were disconnected at the beginning of
this procedure.
5.2 Tasks Required each 50,000 Operating Hours
5.2.1 2U Rear Panel Fans Replacement
According to the fans manufacturer, it is recommended to replace the 2U rear panel fans each
50,000 operating hours (~ 5 years). Please refer to document called “Digital Cinema Server Fan
Shock Mounts Installation Procedure” (document number D2K.DP.000223.DRM) to find
additional guidance about how shock mounting new fans.
To replace the Dolphin fan, just remove its bracket and put a new bracket mounted with a new
fan and the appropriate plastic tunnel.
20
Document #: 9301H29500V1.0