7- IMPORTANT SAFETY INFORMATION 

 

7.1 Fire prevention:  

It is permissible to place the unit on normally flammable surfaces. 
Suitable for mounting on normally flammable materials surfaces greater than 200°C 
with some combustion time lag. 
Minimum distance from the closest illuminable surface: 30 cm. 
Replace any blown or damaged fuses only with those of identical value (1AT). 
 
 

7.2 Prevention from electric shock: 

High voltage is present inside the unit. 
Unplug the unit prior to performing any operation which involves touching the inside of 
the unit. 
This equipment must be grounded, do not connect to non-grounded supplies. 
The use of a thermal magnetic circuit breaker is recommended for each PROFILO 
COMPACT LED 50 unit. Use only AC supplies 90-260V , 50 / 60 Hz.  
PROFILO COMPACT LED 50 should never be located in position exposed to rain or in 
areas of extreme humidity. 
A good air ventilation is essential for proper equipment work.  
 
 

7.3 Safety: 

The external surface of the unit may exeed 50°C; never handle the unit until at least 5 
minutes have elapsed since the unit was turned off. 
Never install the unit in an enclosed area lacking sufficient air flow. 
The ambient temperature should not exeed 40°C and should not be lower than -10°C. 

 
 
8- INPUT / OUTPUT CONNECTIONS 
 

 
 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

FUSE  1AT 

DMX OUT 
XLR 5 Pins Male Panel Connector 

MAINS AC INPUT 90-260V , 50/60 Hz 

 

DMX IN  
XLR 5 Pins Female Panel Connector 

 DISPLAY PANEL 

MAINS AC OUTPUT 90-260V , 50/60 Hz 

MAX 16A 

 

!

Содержание SCENA COMPACT LED 50

Страница 1: ...Made in Italy PROFILO COMPACT LED 50 User s Manual rel 1 0 GB D T S Illuminazione s r l ITALY http www dts lighting it...

Страница 2: ...e products or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ven...

Страница 3: ...URES 5 5 ACCESSORIES 6 6 IMPORTANT SAFETY INFORMATION 7 6 1 Fire prevention 6 2 Prevention of electric shock 6 3 Safety 7 INPUT OUTPUT CONNECTIONS 7 8 DMX SIGNAL CONNECTION 8 8 1 DMX Addresses 8 2 Sel...

Страница 4: ...ING Read the instruction contained in this user manual carefully as they give important information regarding safety during installation use and maintenance The device is not for domestic use and must...

Страница 5: ...LED 50 is contained in a strong housing with folded edges designed to resist all the rigors of continuous use PROFILO COMPACT LED 50 features a reversible yoke for using the projector in any position...

Страница 6: ...e 0508B028 1 x XLR 5 pins female cable connector D T S Code 0508B027 4 x Shutter blades Single blade D T S Code 02SK0041 Optional on request C Clamp G60 Max Load 50 Kg Black finish D T S Code 0521A004...

Страница 7: ...The use of a thermal magnetic circuit breaker is recommended for each PROFILO COMPACT LED 50 unit Use only AC supplies 90 260V 50 60 Hz PROFILO COMPACT LED 50 should never be located in position expo...

Страница 8: ...connected If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX reception problem For Installations where long distance DMX cable con...

Страница 9: ...ickly and you get a faster selection 2 Press ENTER to confirm your selection The numbers on the display will stop flashing and the projector is now controlled by the new DMX address 10 FIRMWARE UPDATI...

Страница 10: ...ons below before carrying out any variations or selections NOTE the symbol shows which key has to be pushed to obtain the desired function Software version 1 00 REVERSE DISPLAY Reverses display s read...

Страница 11: ...n 20 250 ms Smooth response to DMX variation COMPRESSION This menu allows to select between Linear current output or Quadratic current output for LEDs Default Quadratic SYNC This menu allows to adjust...

Страница 12: ...d green light is seen on the transmitter and solid display is seen on PROFILO COMPACT LED 50 2 No DMX signal connected the Antenna transmitter will flash red green display blinking on PROFILO COMPACT...

Страница 13: ...vailable Usefull for Emergency EXIT illumination on public areas Default 204 80 ENTER ENTER Up Down MENU ENTER ENTER Up Down MENU DEFAULT SETTING To restore default settings TEMPERATURE Internal unit...

Страница 14: ...e up from 42 6 s to 120 ms 150 179 Pulse down from 42 6 s to 120 ms 180 204 Random strobe Dimmer channel active 205 229 Full independent Random Strobe Dimmer channel disabled 230 255 Open DMX CHANNEL...

Страница 15: ...Pulse up from 42 6 s to 120 ms 150 179 Pulse down from 42 6 s to 120 ms 180 204 Random strobe Dimmer channel active 205 229 Full independent Random Strobe Dimmer channel disabled 230 255 Open DMX CHAN...

Страница 16: ...tic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein D T S Illumin...

Отзывы: