7
7- IMPORTANT SAFETY INFORMATION
7.1 Fire prevention:
It is permissible to place the unit on normally flammable surfaces.
Suitable for mounting on normally flammable materials surfaces greater than 200°C
with some combustion time lag.
Minimum distance from the closest illuminable surface: 30 cm.
Replace any blown or damaged fuses only with those of identical value (1AT).
7.2 Prevention from electric shock:
High voltage is present inside the unit.
Unplug the unit prior to performing any operation which involves touching the inside of
the unit.
This equipment must be grounded, do not connect to non-grounded supplies.
The use of a thermal magnetic circuit breaker is recommended for each PROFILO
COMPACT LED 50 unit. Use only AC supplies 90-260V , 50 / 60 Hz.
PROFILO COMPACT LED 50 should never be located in position exposed to rain or in
areas of extreme humidity.
A good air ventilation is essential for proper equipment work.
7.3 Safety:
The external surface of the unit may exeed 50°C; never handle the unit until at least 5
minutes have elapsed since the unit was turned off.
Never install the unit in an enclosed area lacking sufficient air flow.
The ambient temperature should not exeed 40°C and should not be lower than -10°C.
8- INPUT / OUTPUT CONNECTIONS
FUSE 1AT
DMX OUT
XLR 5 Pins Male Panel Connector
MAINS AC INPUT 90-260V , 50/60 Hz
DMX IN
XLR 5 Pins Female Panel Connector
DISPLAY PANEL
MAINS AC OUTPUT 90-260V , 50/60 Hz
MAX 16A
!