16
15- RDM FUNCTIONS
RDM STATUS MESSAGE IDs:
Status Message ID Data Value 1 Data Value 2
Status ID Description
0x8000
ERROR PAN MOTOR/ENCODER
0x8001
ERROR PAN LOCKED
0x8002
ERROR PAN ZERO SENSOR
0x8003
ERROR TILT MOTOR/ENCODER
0x8004
ERROR TILT LOCKED
0x8005
ERROR TILT ZERO SENSOR
0x8006
ERROR DMX ADDRESS
0x8007
ERROR PARAMETERS MEMORY
0x8008
ERROR SUPPLY VOLTS TOO LOW
0x8009
ERROR SUPPLY VOLTS TOO HIGH
0x800B
ERROR BUS LED DRIVER CARD
0x800C
card number
ERROR BUS MOTORS CARD %d
0x801F
ERROR TEMPERATURE LED MODULE
0x8020
sensor number
ERROR TEMPERATURE LED DRIVER %d
0x8021
ERROR TEMPERATURE MICRO
0x8027
sensor number
ERROR TEMPERATURE SENSOR %d
0x8028
1=data not present
ERROR COLOUR DATA INTEGRITY CODE %d
*
2=read error
3=incomplete data
*In case of LED Driver PCB replacement will be shown these RDM Status Message IDs.
11- FIRMWARE UPDATING
To update the firmware release of the EUPHONY 3 you need:
- DTS Dongle Firmware Uploader (code 03.LA.206).
-
“DTS Firmware Upgrade Utility v.2.02” program installed on PC.
- Latest firmware release available for EUPHONY 3 unit.
Updating the firmware release.
Please follow the procedure below to perform the update:
1. Connect the DTS Dongle Firmware Uploader to a spare USB port on the PC.
2. Connect the unit DMX input to the DTS Dongle Firmware Uploader DMX output with
a standard DMX cable and turn ON the unit.
3. Send the new firmware release into the unit by usin
g “DTS Firmware Upgrade
Utility v.2.02” program. At the end of the procedure, the unit will reset.
For more information please refer to an authorised DTS service centre.