3. Installation

3.1. Important notice

 

Electrical and automation installations of the drive must be made by experienced and qualified 

personnel according to all regulations in force. Device is designed to operate with dangerous 230V/50Hz 
voltage, turn all power off while installing. EASY B232 control unit is classified as „ Gate and automatic 
doors” category which indicates special safety measures. The installers task is safe installation of the 
device which enables maximum reduction of risks connected with its operation. The person performing 
the  installation  without  compliance  with  all  regulations  is  responsible  for  any  presumptive  damages 
caused by the device.   

3.2. Device description and installation method

 

EASY B232 control unit is main board and casing.  Main board (Fig. 1) has built-in power supply 

adaptor and execution circuit made on special relays and couplings to connect power of servomotor and 
protecting, steering and signalling elements. Moreover, it is equipped with the microprocessor control unit 
with  the  interface  on  LED  diodes,  DIP-SWITCHes,  MICROSWITCH  button  and  rotational 
potentiometers. The casing of the control unit has   IP 55 level of tightness. Impairments placed in the 
lower part of the casing are for placing fixing bolts which mount the control unit to the surface. Impairments 
in the side parts of the casing are to lead installation wires of the control unit. After making the hole it is 
necessary to apply attached rubber gland of the diameter 25mm. The wires should be led to the device 
through lower part of the casing. While making holes in the casing it is necessary to guarantee required 
“IP” tightness. The presence of the supply voltage is being signalled with LED POWER diode lighting. 

Fig. 1.

 Main board

1. fuse (4A/250V, T) 
2. power supply connector 230V AC
3. connector for engine 1
4. connector for engine 2
5. signal lamp connector, 230V AC, max. 6A

Содержание EASY B232

Страница 1: ...S GATE CONTROL UNIT installation and manual version 2 7 EASY B232 DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 Bydgoszcz tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl ...

Страница 2: ......

Страница 3: ...maximum power in built condenser quantity 230VAC 2 x 350W none 2 Signal lamp output transmitted max 230VAC 6A and OC max 24VDC 6W Periphery power output photocells bolt etc 24V DC 0 5A Photocells transmitter power supply output OC type see function PHOTO TEST Gate bolt output 12V DC engaged for 8 sec on the start of opening Additional output relay potential free max 1A 30V AC DC operating in bista...

Страница 4: ...connection Outputs digital steering output Memory capacity 35 remote controls every with individual number in memory Remote control configuration possibility to subscribe any of three functions OPEN A OPEN B OPEN C to any remote control button Possibility to delete all memory yes Possibility to delete single remote control yes Possibility to subjoin remote control without the necessity to access c...

Страница 5: ...ptor and execution circuit made on special relays and couplings to connect power of servomotor and protecting steering and signalling elements Moreover it is equipped with the microprocessor control unit with the interface on LED diodes DIP SWITCHes MICROSWITCH button and rotational potentiometers The casing of the control unit has IP 55 level of tightness Impairments placed in the lower part of t...

Страница 6: ... MOTOR2 PE OPEN COM CLOSE Servomotor which opens as first important when the leaves open lap should be connected to MOTOR1terminals SecondservomotorshouldbeconnectedtoMOTOR2terminals Enginecondensers proper for this type of servomotor should be connected betweenOPEN andCLOSE terminals of the servomotors The servomotor opening wire should be connected toOPEN terminal closing wire toCLOSE terminal c...

Страница 7: ...d should absolutely be programmed in order to adapt its operating parameters to the current installation in particular it is necessary always to set the power of the servomotor always to programme opening and closing times All the envisaged connections should scrupulously followed In the uncertain situation it is forbidden to try out only to read relevant detailed technical cards of installed devi...

Страница 8: ... type to theOPENC terminal This button will activate additional channel outputOUTC All unused inputs of NO type should be left not connected Activating the button of the manual steering consists in its momentary pressing OPENA B and C inputs are functional equivalent of radio receiver channels channelA B andC 3 3 10 EasyRXradioreceiverconnector This connector enables the control of servomotor with...

Страница 9: ...he servomotor is a result of switching the directionasaresultofdisturbingthephotocell OVER PUSHING start of the servomotor with the maximum powerturnedon ON orturnedoff OFF PRE FLASHING preliminary five second signalling of the lampbeforethemoveofthegateturnedon ON orturnedoff OFF BLINKING LAMP controlling with lamp without the contact breakerbuiltin ON orwithlampwithitsowncontactbreaker OFF Thela...

Страница 10: ...ons as well as tothevitalityofmechanicalfittings 5 4 PrzełącznikDIP SWITCHsekcjaMODE tryb logika pracysterownikaEASYB232 DIP SWITCHMODEsection EASYB232controlunitoperationmode logic BelowthereareoperationmodesofEASYcontrolunit Itisnecessarytoanalysetheuserneedsandnext chooseappropriateamongavailable 5 4 1 1 Amode Automatic mode it has function of auto closing the gate after the set time maximum 12...

Страница 11: ... rewers blocks OPEN A B PHOTO CL rewers PHOTO OP CL blocks OPEN A B blocks OPEN A B otwiera bramę i zamyka po czasie autozamykania otwiera furtkę i zamyka po czasie autozamykania closes the gate countdown autoc losing time countdown autoc losing time closes the gate partially blocks closings blocks opening blocks closings opens closing stopped open closed 5s after unlock closes 5s after unlock clo...

Страница 12: ...UT STOP blocks OPEN A B stop stop blocks OPEN A B PHOTO OP blocks OPEN A B rewers blocks OPEN A B PHOTO CL rewers blocks OPEN A B blocks OPEN A B blocks OPEN A B blocks OPEN A B blocks OPEN A B PHOTO OP CL blocks OPEN A B opens the gate opens partially closes closes blocks closings blocks closings stop until unlock opens stop until unlock opens opens closing stopped open closed Tab 5 5 B mode 5 B ...

Страница 13: ...ed open closed Tab 6 6 C mode 6 C mode OPEN_A opens stop opens OPEN_B stop closes closes INPUT STOP blocks OPEN A stop stop blocks OPEN A B blocks OPEN B PHOTO OP blocks OPEN A stop blocks OPEN A PHOTO CL stop blocks OPEN A B blocks OPEN A B PHOTO OP CL blocks OPEN A stop stop blocks OPEN A B blocks OPEN A B opens closing stopped open closed Tab 7 7 P mode 7 PA mode OPEN_A stop rewers OPEN_B stop ...

Страница 14: ...ogrammedontheremotecontrolcanbeusedinsteadofLEARNbutton leavesstartthemovementtowardsopening secondpressing oftheearlierchosenbutton theleavesstop LEDLEARNdiodegoesoff 5 6 LearninginEXTENDEDmode This procedure requires more involvement in the process the learning from the fitter than in case of the simplified mode The fitter is able to set slowdown times at opening slowdowns at closing opening and...

Страница 15: ...ing leaf2startsslowedmovetowardsclosing tenthpressing leaf2increasesspeedtostandardclosingspeed eleventhpressing leaf2issloweddown twelfthpressing leaf2stops thirteenthpressing leaf1startsslowedmovetowardsclosing fourteenthpressing leaf1increasesspeedtostandardclosingspeed fifteenthpressing leaf1issloweddown sixteenthpressing leaf1stopsandtheprocedureisfinished LEARNLEDdiodegoesoff Inordertosetthe...

Страница 16: ...oraerialconnection In the brand new receiver an inside aerial 170 mm long is connected to the terminal To increase the range of the radio remote control it is necessary to connect outside stubby aerial To connect the coaxial cable of the outside aerial to the terminal centre vein of the cable and to the terminal cable screen In order to achievetheoptimumradioreachitisimportanttorememberabout negat...

Страница 17: ...he way to the end of the procedure After about 4 sec A diode turns on it means that currently the blocking of remote subscriptionisturnedoff weholdthebuttonallthetime After4consecutivesecondsBdiodeturnson itmeans that the function of remote subscription will be blocked When we release the button kept the card will remember settings and remote subscribing of remote controls will be blocked The proc...

Страница 18: ...r memory when we press and hold for more that 15 secondsAandBbuttons CAUTION Format process of the memory card causes irreversible removal of all remote controls and turning off the block of remote subscribing of remote controls 6 9 BoardofradioreceiverEasyRX 1 channelAsignaldiode 2 Achannelbutton 3 channelBsignaldiode 4 Bchannelbutton 5 connectorofthecard 6 channelCsignaldiode 7 Cchannelbutton 8 ...

Страница 19: ...alled it is necessary to cause manual disturbance of the OP photocell on the controller board a PHOTO diode should go out 1 Act the same for theCL photocell andOP CL if are installed In sleeping mode when optical crash barriers aren t disturbed signalling PHOTO diodes 1 2 and 3 should shine If it isn t so it means error in photocells operation incorrect connecting not synchronizing the transmitter...

Страница 20: ...ng the warranty period there are problems which come because of his fault Broken device should be supplied on customer s expense to the place of purchase and enclose clear and brief description of the breakage The cost of mount dismount is covered by the user The warranty does not cover batteries in the remote controls faults caused by improper usage user self repairs and adaptations lightning str...

Страница 21: ...duce the amount of hazardous substances in waste The underlying purpose is to promote the avoidance recovery and risk free disposal of waste DTMSystemherebydeclaresthatthegatecontrollercomplieswithDirective2014 53 EU The full text of the EU Declaration of Conformity is available at the Internet address www dtm pl ...