DTM System EASY B232 Скачать руководство пользователя страница 3

1. Introduction

 

EASY B232 gate control unit is used to control drives of double leaf gates powered by alternating 

voltage 230V, 50 Hz, max power 350W. With the cooperation of the Easy RX radio card of the capacity of 
35 remote controls DTM433MHz series (secured transmission based on the Keeloq system), the driver 
gains the radio control function.
The drive has a function of slowing down the move during the start and/or stopping and   adjustment of 
servomotor power. By adjusting the right mode of the driver we can complete automation system with 
function  of  the  automatic  gate  closure  after  time  (time  of  auto  closure  is  regulated  from  1  up  to  120 
seconds), function of photo closure (automatic closure of the gate with time 5 seconds, started after the 
infringement  and  repeated  dismissal  of  photocells)  EASY  232  has  output  of  gate  bolt  control  and 
additional  output  with  manual  and  radio  steering,  which  can  work  under  the  bistable  procedure 
(connect/disconnect) or monostable (connect for 4 sec.), intended for connecting outside device.
Signal lamp power output 230 VAC / 50 Hz, enables connecting both lamp with the contact breaker built in, 
as well as without (recommended). Additionally the driver is equipped with the signal lamp output LED 24 
VDC/ 6W.

The operation of control unit depends on chosen work mode, see p. 5.4. 

2. . Technical data

Basic parameters

- Power supply 

 

 

 

 

 

230 AC V, 50 Hz

- Power consumption in non-active status 

 

 

 

8VA

- Operational temperature (min./max.) 

 

 

 

-20°C /+55°C

- External dimensions (width. x depth x height) 

 

 

180 x 95 x 241 mm or 120 x 80 x 166 mm

- Installation 

 

 

 

 

 

surface mounted

- Weight   

 

 

 

 

 

1,1 kg

- IP 

 

 

 

 

 

 

55

 

Outputs/Inputs

- Servomotor output (voltage / maximum power/in built condenser/quantity)  230VAC / 2 x 350W / none/ 2  
- Signal lamp output  transmitted  

 

 

 

max. 230VAC/6A and OC max. 24VDC/6W

- Periphery power output (photocells, bolt, etc.) 

 

 

24V DC, 0,5A

- Photocells transmitter power supply output  

 

 

OC type (see function PHOTO-TEST)

- Gate bolt output 

 

 

 

 

 

12V DC, engaged for 8 sec. on the start of opening

- Additional output 

 

 

 

 

 

relay (potential free) max. 1A/30V AC/DC operating in bistable 

 

 

 

 

 

 

 

or monostable mode engaging time 4  sec (programmable 

 

 

 

 

 

 

 

with DIP-SWITCH, p.5.2.1)

- Photocell inputs/ number 

 

 

 

 

NC type / 3

- Manual steering input OPEN A   

 

 

 

NO type

- Manual steering input OPEN B   

 

 

 

NO type

- Additional channel manual steering input OPEN C 

 

 

NO type

- Manual steering input STOP 

 

 

 

 

NC type

Steering part

- Regulation of opening and closing time and soft start/stop phases  

1 sec. to 255 sec. (exact to 1 sec.) – learning function

- Power of servomotors regulation 

 

 

 

yes, separately for servomotor 1 and 2 

- Regulation of second leaf delay   

 

 

 

with the help of potentiometers from 1 to 15 seconds

- 8 modes of servomotor work 

 

 

 

 

programmable with DIP-SWITCH, p.5.4

- Start with maximum strength    

 

 

 

programmable with DIP-SWITCH, p.5.2.1

- Auto-closing gate function 

 

 

 

 

yes, regulation with the help of potentiometer from 1 to 120s

- Photo-closing function 

 

 

 

 

yes, constant time after which the gate is closed 5 sec

- Pushing with increased power after closing, start with increased power 

programmable with DIP-SWITCH, p.5.2.1

- Initial work of signal lamp 

 

 

 

 

programmable with DIP-SWITCH, p.5.2.1

- Photo test (testing of photocells before the gate move) 

 

yes, p. 5.2.1

- Equipment user interface 

 

 

 

 

DIP-SWITCH to set control unit operation mode and switching 

 

 

 

 

 

 

 

additional functions, LEARN button to conduct learning of 

 

 

 

 

 

 

 

opening and closing time (slowdown), signal LED diodes

- Device configuration memory   

 

 

 

non-transistory

- Radio steering  

 

 

 

 

 

in option through connection for radio receiver available on 

 

 

 

 

 

 

 

the board 

1

Содержание EASY B232

Страница 1: ...S GATE CONTROL UNIT installation and manual version 2 7 EASY B232 DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 Bydgoszcz tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl ...

Страница 2: ......

Страница 3: ...maximum power in built condenser quantity 230VAC 2 x 350W none 2 Signal lamp output transmitted max 230VAC 6A and OC max 24VDC 6W Periphery power output photocells bolt etc 24V DC 0 5A Photocells transmitter power supply output OC type see function PHOTO TEST Gate bolt output 12V DC engaged for 8 sec on the start of opening Additional output relay potential free max 1A 30V AC DC operating in bista...

Страница 4: ...connection Outputs digital steering output Memory capacity 35 remote controls every with individual number in memory Remote control configuration possibility to subscribe any of three functions OPEN A OPEN B OPEN C to any remote control button Possibility to delete all memory yes Possibility to delete single remote control yes Possibility to subjoin remote control without the necessity to access c...

Страница 5: ...ptor and execution circuit made on special relays and couplings to connect power of servomotor and protecting steering and signalling elements Moreover it is equipped with the microprocessor control unit with the interface on LED diodes DIP SWITCHes MICROSWITCH button and rotational potentiometers The casing of the control unit has IP 55 level of tightness Impairments placed in the lower part of t...

Страница 6: ... MOTOR2 PE OPEN COM CLOSE Servomotor which opens as first important when the leaves open lap should be connected to MOTOR1terminals SecondservomotorshouldbeconnectedtoMOTOR2terminals Enginecondensers proper for this type of servomotor should be connected betweenOPEN andCLOSE terminals of the servomotors The servomotor opening wire should be connected toOPEN terminal closing wire toCLOSE terminal c...

Страница 7: ...d should absolutely be programmed in order to adapt its operating parameters to the current installation in particular it is necessary always to set the power of the servomotor always to programme opening and closing times All the envisaged connections should scrupulously followed In the uncertain situation it is forbidden to try out only to read relevant detailed technical cards of installed devi...

Страница 8: ... type to theOPENC terminal This button will activate additional channel outputOUTC All unused inputs of NO type should be left not connected Activating the button of the manual steering consists in its momentary pressing OPENA B and C inputs are functional equivalent of radio receiver channels channelA B andC 3 3 10 EasyRXradioreceiverconnector This connector enables the control of servomotor with...

Страница 9: ...he servomotor is a result of switching the directionasaresultofdisturbingthephotocell OVER PUSHING start of the servomotor with the maximum powerturnedon ON orturnedoff OFF PRE FLASHING preliminary five second signalling of the lampbeforethemoveofthegateturnedon ON orturnedoff OFF BLINKING LAMP controlling with lamp without the contact breakerbuiltin ON orwithlampwithitsowncontactbreaker OFF Thela...

Страница 10: ...ons as well as tothevitalityofmechanicalfittings 5 4 PrzełącznikDIP SWITCHsekcjaMODE tryb logika pracysterownikaEASYB232 DIP SWITCHMODEsection EASYB232controlunitoperationmode logic BelowthereareoperationmodesofEASYcontrolunit Itisnecessarytoanalysetheuserneedsandnext chooseappropriateamongavailable 5 4 1 1 Amode Automatic mode it has function of auto closing the gate after the set time maximum 12...

Страница 11: ... rewers blocks OPEN A B PHOTO CL rewers PHOTO OP CL blocks OPEN A B blocks OPEN A B otwiera bramę i zamyka po czasie autozamykania otwiera furtkę i zamyka po czasie autozamykania closes the gate countdown autoc losing time countdown autoc losing time closes the gate partially blocks closings blocks opening blocks closings opens closing stopped open closed 5s after unlock closes 5s after unlock clo...

Страница 12: ...UT STOP blocks OPEN A B stop stop blocks OPEN A B PHOTO OP blocks OPEN A B rewers blocks OPEN A B PHOTO CL rewers blocks OPEN A B blocks OPEN A B blocks OPEN A B blocks OPEN A B blocks OPEN A B PHOTO OP CL blocks OPEN A B opens the gate opens partially closes closes blocks closings blocks closings stop until unlock opens stop until unlock opens opens closing stopped open closed Tab 5 5 B mode 5 B ...

Страница 13: ...ed open closed Tab 6 6 C mode 6 C mode OPEN_A opens stop opens OPEN_B stop closes closes INPUT STOP blocks OPEN A stop stop blocks OPEN A B blocks OPEN B PHOTO OP blocks OPEN A stop blocks OPEN A PHOTO CL stop blocks OPEN A B blocks OPEN A B PHOTO OP CL blocks OPEN A stop stop blocks OPEN A B blocks OPEN A B opens closing stopped open closed Tab 7 7 P mode 7 PA mode OPEN_A stop rewers OPEN_B stop ...

Страница 14: ...ogrammedontheremotecontrolcanbeusedinsteadofLEARNbutton leavesstartthemovementtowardsopening secondpressing oftheearlierchosenbutton theleavesstop LEDLEARNdiodegoesoff 5 6 LearninginEXTENDEDmode This procedure requires more involvement in the process the learning from the fitter than in case of the simplified mode The fitter is able to set slowdown times at opening slowdowns at closing opening and...

Страница 15: ...ing leaf2startsslowedmovetowardsclosing tenthpressing leaf2increasesspeedtostandardclosingspeed eleventhpressing leaf2issloweddown twelfthpressing leaf2stops thirteenthpressing leaf1startsslowedmovetowardsclosing fourteenthpressing leaf1increasesspeedtostandardclosingspeed fifteenthpressing leaf1issloweddown sixteenthpressing leaf1stopsandtheprocedureisfinished LEARNLEDdiodegoesoff Inordertosetthe...

Страница 16: ...oraerialconnection In the brand new receiver an inside aerial 170 mm long is connected to the terminal To increase the range of the radio remote control it is necessary to connect outside stubby aerial To connect the coaxial cable of the outside aerial to the terminal centre vein of the cable and to the terminal cable screen In order to achievetheoptimumradioreachitisimportanttorememberabout negat...

Страница 17: ...he way to the end of the procedure After about 4 sec A diode turns on it means that currently the blocking of remote subscriptionisturnedoff weholdthebuttonallthetime After4consecutivesecondsBdiodeturnson itmeans that the function of remote subscription will be blocked When we release the button kept the card will remember settings and remote subscribing of remote controls will be blocked The proc...

Страница 18: ...r memory when we press and hold for more that 15 secondsAandBbuttons CAUTION Format process of the memory card causes irreversible removal of all remote controls and turning off the block of remote subscribing of remote controls 6 9 BoardofradioreceiverEasyRX 1 channelAsignaldiode 2 Achannelbutton 3 channelBsignaldiode 4 Bchannelbutton 5 connectorofthecard 6 channelCsignaldiode 7 Cchannelbutton 8 ...

Страница 19: ...alled it is necessary to cause manual disturbance of the OP photocell on the controller board a PHOTO diode should go out 1 Act the same for theCL photocell andOP CL if are installed In sleeping mode when optical crash barriers aren t disturbed signalling PHOTO diodes 1 2 and 3 should shine If it isn t so it means error in photocells operation incorrect connecting not synchronizing the transmitter...

Страница 20: ...ng the warranty period there are problems which come because of his fault Broken device should be supplied on customer s expense to the place of purchase and enclose clear and brief description of the breakage The cost of mount dismount is covered by the user The warranty does not cover batteries in the remote controls faults caused by improper usage user self repairs and adaptations lightning str...

Страница 21: ...duce the amount of hazardous substances in waste The underlying purpose is to promote the avoidance recovery and risk free disposal of waste DTMSystemherebydeclaresthatthegatecontrollercomplieswithDirective2014 53 EU The full text of the EU Declaration of Conformity is available at the Internet address www dtm pl ...

Страница 22: ......

Страница 23: ......

Страница 24: ...DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 Bydgoszcz Polska http www dtm pl ...

Отзывы: