1. Introduction
EASY B232 gate control unit is used to control drives of double leaf gates powered by alternating
voltage 230V, 50 Hz, max power 350W. With the cooperation of the Easy RX radio card of the capacity of
35 remote controls DTM433MHz series (secured transmission based on the Keeloq system), the driver
gains the radio control function.
The drive has a function of slowing down the move during the start and/or stopping and adjustment of
servomotor power. By adjusting the right mode of the driver we can complete automation system with
function of the automatic gate closure after time (time of auto closure is regulated from 1 up to 120
seconds), function of photo closure (automatic closure of the gate with time 5 seconds, started after the
infringement and repeated dismissal of photocells) EASY 232 has output of gate bolt control and
additional output with manual and radio steering, which can work under the bistable procedure
(connect/disconnect) or monostable (connect for 4 sec.), intended for connecting outside device.
Signal lamp power output 230 VAC / 50 Hz, enables connecting both lamp with the contact breaker built in,
as well as without (recommended). Additionally the driver is equipped with the signal lamp output LED 24
VDC/ 6W.
The operation of control unit depends on chosen work mode, see p. 5.4.
2. . Technical data
Basic parameters
- Power supply
230 AC V, 50 Hz
- Power consumption in non-active status
8VA
- Operational temperature (min./max.)
-20°C /+55°C
- External dimensions (width. x depth x height)
180 x 95 x 241 mm or 120 x 80 x 166 mm
- Installation
surface mounted
- Weight
1,1 kg
- IP
55
Outputs/Inputs
- Servomotor output (voltage / maximum power/in built condenser/quantity) 230VAC / 2 x 350W / none/ 2
- Signal lamp output transmitted
max. 230VAC/6A and OC max. 24VDC/6W
- Periphery power output (photocells, bolt, etc.)
24V DC, 0,5A
- Photocells transmitter power supply output
OC type (see function PHOTO-TEST)
- Gate bolt output
12V DC, engaged for 8 sec. on the start of opening
- Additional output
relay (potential free) max. 1A/30V AC/DC operating in bistable
or monostable mode engaging time 4 sec (programmable
with DIP-SWITCH, p.5.2.1)
- Photocell inputs/ number
NC type / 3
- Manual steering input OPEN A
NO type
- Manual steering input OPEN B
NO type
- Additional channel manual steering input OPEN C
NO type
- Manual steering input STOP
NC type
Steering part
- Regulation of opening and closing time and soft start/stop phases
1 sec. to 255 sec. (exact to 1 sec.) – learning function
- Power of servomotors regulation
yes, separately for servomotor 1 and 2
- Regulation of second leaf delay
with the help of potentiometers from 1 to 15 seconds
- 8 modes of servomotor work
programmable with DIP-SWITCH, p.5.4
- Start with maximum strength
programmable with DIP-SWITCH, p.5.2.1
- Auto-closing gate function
yes, regulation with the help of potentiometer from 1 to 120s
- Photo-closing function
yes, constant time after which the gate is closed 5 sec
- Pushing with increased power after closing, start with increased power
programmable with DIP-SWITCH, p.5.2.1
- Initial work of signal lamp
programmable with DIP-SWITCH, p.5.2.1
- Photo test (testing of photocells before the gate move)
yes, p. 5.2.1
- Equipment user interface
DIP-SWITCH to set control unit operation mode and switching
additional functions, LEARN button to conduct learning of
opening and closing time (slowdown), signal LED diodes
- Device configuration memory
non-transistory
- Radio steering
in option through connection for radio receiver available on
the board
1