5.1.

 

SW button and LED STATUS

 

The SW button (see fig. 2, point 19) is used to restore the default settings of the controller.

The STATUS diode is a status diode informing about the controller operation.

5.2. Pairing the controller with Bluetooth™ device.

 

In  order  to  use  the  application  to  configure  the  device,  it  is  necessary  to  pair  the  controller 

Bluetooth™ interface with the device from which the configuration will be carried out, eg a telephone.

5.2.1. Launching the Application and Bluetooth ™ communication

 

Run the Blue Motor Control application and if Bluetooth was not previously turned on in the 

phone, let the application turn it on.

Programming

Figure 6.

 Enabling Bluetooth ™ on the configuring device.

Содержание BLUE 232

Страница 1: ...AUTOMATION SYSTEMS DOUBLE LEAF GATE CONTROLLER manual version 1 6 BLUE 232 DTM System ul Brzeska 7 85 145 Bydgoszcz tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl ...

Страница 2: ......

Страница 3: ...opening begins Additional output in bistable monostable mode relay potential free max 1A 30V AC DC Photocell inputs quantity programmable NC type 3 Manual control input A B C programmable NO type Manual control STOP input NC type Limit switches input on opening and closing NC type 4 Motor encoder input digital 2 Control part Adjustable opening and closing time soft stop phases 1 120s 0 15s with an...

Страница 4: ...4 ...

Страница 5: ...tions is responsible for any damage that the device may cause 3 2 Description of the device and installation method The BLUE 232 controller includes a motherboard and a housing The housing has four points for mounting it on a vertical surface 1 and cable glands on each side The main board fig 2 should be screwed to points 2 in fig 1 The controller is equipped with a Bluetooth communication system ...

Страница 6: ...on 11 aditional relay output NO 12 LED lamp connector ground potential max 6W gate lock output 12 24V DC power supply 24V 13 connection for connecting the limit switches of the actuator 1 14 connector for connecting the limit switches of the actuator 2 15 connector for connecting the encoder of the actuator 1 16 connector for connecting the encoder of the actuator 2 17 connector for connecting the...

Страница 7: ... should be connected to CAP1 and CAP2 connectors 3 3 4 Terminals for connecting a 24V 6W signal lamp Clamps are used to connect a 24V LED lamp with a maximum power of 6W Connect it to the LAMP and 24V terminals fig 2 In the case of a lamp with a built in interrupter turn off the interrupter function in the controller 3 3 5 Clamps for connecting the gate bolt The controller is equipped with an outp...

Страница 8: ...allel to the entrance edge 3 3 9 Manual control terminals INPUT STOP and A B C The NC type safety button must be connected to the INPUT STOP terminals If the button is not used short circuit the terminals with a wire Momentary NO type buttons can be connected to A B C terminals which will control the drive operation in accordance with the program settings Make the settings from the level of the Bl...

Страница 9: ...cation CAUTION The control panel settings that are not adjusted to the installation conditions may soon lead to its destruction and loss of warranty After completing the stage of creating the installation and connecting devices it is necessary to program the control panel in order to adjust its operating parameters to the current installation in particular always adjust the power of the actuators ...

Страница 10: ...ary to re synchronize the gate leaves which should be done as follows trigger the OPEN movement wait until both leaves are fully opened it may be necessary to first call the CLOSE direction and then OPEN direction 5 Programming the BLUE 232 controller The BLUE 232 controller is programmed to the needs of a given installation using a dedicated Blue Motor Control application forAndroid devices commu...

Страница 11: ... In order to use the application to configure the device it is necessary to pair the controller Bluetooth interface with the device from which the configuration will be carried out eg a telephone 5 2 1 Launching theApplication and Bluetooth communication Run the Blue Motor Control application and if Bluetooth was not previously turned on in the phone let the application turn it on Programming Figu...

Страница 12: ...l panels are to be operated nearby select the one you want to configure from the list 5 2 3 PIN code for the controller If the application connects to the controller for the first time it will ask for a pin code 0000 by default Figure 7 Search and select a controller fron the list Figure 8 PIN code request on first startup ...

Страница 13: ...ttings Restoring the factory settings does not remove the remotes from the controller memory CAUTION Lowering the operating power of the actuators has a positive effect on safety conditions as well as on the service life of the mechanical elements of the installation CAUTION Violation of the photocells and blocking the gate during the learning process will not stop the actuator If necessary the ga...

Страница 14: ... installed the OP photocells must be manually violated the OP LED should go out on the control board Do the same for the CL photocell and OP CL if fitted In the rest state when the optical barriers are not violated the OP CL OP CL diodes should be on If it is not it means an error in the operation of the photocells incorrect connection not synchronizing the transmitter with the receiver or photoce...

Страница 15: ... System provides the devices that are operational and ready for use The warranty is granted for a period of 30 months from the date of sale by the manufacturer The warranty period is determined based on the manufacturer s warranty seals identifying the production batch placed on each product To recognize the warranty it is necessary to present a sales document The manufacturer undertakes to repair...

Страница 16: ...DTM System ul Brzeska 7 85 145 Bydgoszcz Polska http www dtm pl e mail dtm dtm pl D E S I G N A N D P R O D U C T I O N O F E L E C T R O N I C D E V I C E S ...