3.3. Description of the electrical connections of the BLUE 232 controller

   

Connection to the 230VAC electrical network may only be performed by a qualified specialist with 

appropriate  authorizations.  The  delivered  controller  is  immediately  ready  for  operation.  Connect  all 
installed additional protection and control devices to the appropriate terminals in accordance with the 
connection diagrams.

3.3.1. Mains supply terminals 230VAC, 50Hz (L, N, PE)
 

This connector is intended to connect the controller power supply from the 230VAC, 50Hz mains. 

The power supply circuit to which the controller will be connected should be equipped with a switch that 
cuts off the power supply to the control board. As a standard, the phase conductor is connected to the L 
terminal, the neutral conductor to the N terminal, and the protective conductor (yellow-green) to the PE 
terminal.

3.3.2. Terminals for connecting the MOTOR 1 and MOTOR 2 actuators (PE, OPEN, COM, 
CLOSE)
 

The actuator that opens first (important when the leaves close "overlap") should be connected to 

the 

MOTOR1

 terminals. The second actuator should be connected to the 

MOTOR2

 terminals. Connect 

the actuator's opening wire to the 

OPEN

 terminal, the closing wire to the 

CLOSE

 terminal, the common 

wire to the 

COM

 terminal and the actuator's protective wire to the 

PE

 terminal.

3.3.3. Terminals for connection of CAP1 and CAP2 motor capacitors

 

Motor capacitors, appropriate for the given type of actuators, should be connected to 

CAP1

 and 

CAP2

 connectors.

3.3.4. Terminals for connecting a 24V / 6W signal lamp

 

Clamps are used to connect a 24V LED lamp with a maximum power of 6W. Connect it to the 

LAMP and + 24V terminals (fig. 2.). In the case of a lamp with a built-in interrupter, 

turn off

 the interrupter 

function in the controller.

3.3.5. Clamps for connecting the gate bolt (      )
 

The controller is equipped with an output that can control the 12 / 24V DC gate bolt. Remember 

about the maximum load capacity of the accessory power output, 0.5A in total.

3.3.6. Additional output terminals (OUT C)
 

The controller is equipped with a relay with leaded NO contacts with a maximum load capacity of 

30VAC / DC 1A, enabling the control of an additional device, such as an electrolock, additional controller, 
lighting (using an additional relay with an appropriate load capacity), etc. The output is switched on with 
the OPEN C manual control button or button on the remote control.

3.3.7. Accessory power supply terminals (+ 24VDC)

 

The controller has a 24VDC accessory power supply output, max. 0.5A. The output has two 

equal screw terminals with a ground potential (0V) and a potential of + 24V.

230V AC

50 Hz

PROTECTIVE CONDUCT

OR

NEUTRAL

PHASE

L

N

PE

Mains 

supply 

terminals

capacitor M1

capacitor M2

L

N

PE

OPEN COMCLOSE

PE

PE

CLOSE

COM

OPEN

MOTOR 2

MOTOR 1

CAP 1

CAP 2

PE

N

L

YELLOW - GREEN*

BROWN*

BLACK*

GRA

Y*

M2

right actuator*

230VAC

max.350W

M1

YELLOW - GREEN*

GRA

Y*

BLACK*

BROWN*

left actuator*

230VAC

max.350W

Figure 3.

 View of the terminals for connecting 

the controller power supply and connecting 
the motors with capacitors.

Electrical connections

7

 * referst to the DTM300/400/600 actuators

Содержание BLUE 232

Страница 1: ...AUTOMATION SYSTEMS DOUBLE LEAF GATE CONTROLLER manual version 1 6 BLUE 232 DTM System ul Brzeska 7 85 145 Bydgoszcz tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl ...

Страница 2: ......

Страница 3: ...opening begins Additional output in bistable monostable mode relay potential free max 1A 30V AC DC Photocell inputs quantity programmable NC type 3 Manual control input A B C programmable NO type Manual control STOP input NC type Limit switches input on opening and closing NC type 4 Motor encoder input digital 2 Control part Adjustable opening and closing time soft stop phases 1 120s 0 15s with an...

Страница 4: ...4 ...

Страница 5: ...tions is responsible for any damage that the device may cause 3 2 Description of the device and installation method The BLUE 232 controller includes a motherboard and a housing The housing has four points for mounting it on a vertical surface 1 and cable glands on each side The main board fig 2 should be screwed to points 2 in fig 1 The controller is equipped with a Bluetooth communication system ...

Страница 6: ...on 11 aditional relay output NO 12 LED lamp connector ground potential max 6W gate lock output 12 24V DC power supply 24V 13 connection for connecting the limit switches of the actuator 1 14 connector for connecting the limit switches of the actuator 2 15 connector for connecting the encoder of the actuator 1 16 connector for connecting the encoder of the actuator 2 17 connector for connecting the...

Страница 7: ... should be connected to CAP1 and CAP2 connectors 3 3 4 Terminals for connecting a 24V 6W signal lamp Clamps are used to connect a 24V LED lamp with a maximum power of 6W Connect it to the LAMP and 24V terminals fig 2 In the case of a lamp with a built in interrupter turn off the interrupter function in the controller 3 3 5 Clamps for connecting the gate bolt The controller is equipped with an outp...

Страница 8: ...allel to the entrance edge 3 3 9 Manual control terminals INPUT STOP and A B C The NC type safety button must be connected to the INPUT STOP terminals If the button is not used short circuit the terminals with a wire Momentary NO type buttons can be connected to A B C terminals which will control the drive operation in accordance with the program settings Make the settings from the level of the Bl...

Страница 9: ...cation CAUTION The control panel settings that are not adjusted to the installation conditions may soon lead to its destruction and loss of warranty After completing the stage of creating the installation and connecting devices it is necessary to program the control panel in order to adjust its operating parameters to the current installation in particular always adjust the power of the actuators ...

Страница 10: ...ary to re synchronize the gate leaves which should be done as follows trigger the OPEN movement wait until both leaves are fully opened it may be necessary to first call the CLOSE direction and then OPEN direction 5 Programming the BLUE 232 controller The BLUE 232 controller is programmed to the needs of a given installation using a dedicated Blue Motor Control application forAndroid devices commu...

Страница 11: ... In order to use the application to configure the device it is necessary to pair the controller Bluetooth interface with the device from which the configuration will be carried out eg a telephone 5 2 1 Launching theApplication and Bluetooth communication Run the Blue Motor Control application and if Bluetooth was not previously turned on in the phone let the application turn it on Programming Figu...

Страница 12: ...l panels are to be operated nearby select the one you want to configure from the list 5 2 3 PIN code for the controller If the application connects to the controller for the first time it will ask for a pin code 0000 by default Figure 7 Search and select a controller fron the list Figure 8 PIN code request on first startup ...

Страница 13: ...ttings Restoring the factory settings does not remove the remotes from the controller memory CAUTION Lowering the operating power of the actuators has a positive effect on safety conditions as well as on the service life of the mechanical elements of the installation CAUTION Violation of the photocells and blocking the gate during the learning process will not stop the actuator If necessary the ga...

Страница 14: ... installed the OP photocells must be manually violated the OP LED should go out on the control board Do the same for the CL photocell and OP CL if fitted In the rest state when the optical barriers are not violated the OP CL OP CL diodes should be on If it is not it means an error in the operation of the photocells incorrect connection not synchronizing the transmitter with the receiver or photoce...

Страница 15: ... System provides the devices that are operational and ready for use The warranty is granted for a period of 30 months from the date of sale by the manufacturer The warranty period is determined based on the manufacturer s warranty seals identifying the production batch placed on each product To recognize the warranty it is necessary to present a sales document The manufacturer undertakes to repair...

Страница 16: ...DTM System ul Brzeska 7 85 145 Bydgoszcz Polska http www dtm pl e mail dtm dtm pl D E S I G N A N D P R O D U C T I O N O F E L E C T R O N I C D E V I C E S ...

Отзывы: