background image

DTC COMMUNICATIONS, INC.

19

CONTACT US

Director
State & Local Agencies & International Sales

Michael  Demos

(Nashua Main Office Numbers)

direct voice (603) 546-2120
cell (603) 320-3255
[email protected]

Sales Representatives

Nashua Main Office Numbers

voice (603) 880-4411
toll free (800) 233-8639
fax (603) 880-6965

Director of Federal Sales

John Morgan

(Nashua Main Office Numbers)

direct voice (603) 546-2122
cell (603) 320-3257
[email protected]

Inside Sales

Christine Guzman

(Nashua Main Office Numbers)

direct voice (603) 546-2217
[email protected]
ME, NH, VT

OEM Sales Manager

Ralph Descheneaux

(Nashua Main Office Numbers)

direct voice (603) 546-2119
cell (603) 738-3627
[email protected]

REGIONAL SALES MANAGERS

Howard Rich

toll free (888) 819-8570
voice (860) 626-8570
fax (860) 626-8571
NY, MA, CT, RI, PA, NJ, MD, DE,
WV, DC
[email protected]

Floyd Flowers

voice (208) 667-5197
fax (208) 676-8107
WA, OR, ID, MT, ND, WY, SD

Gary Nichols

toll free (866) 794-2823
voice (765) 473-8917
fax (765) 473-8920
MN, WI, MI, IA, MO, IL,
IN, OH, KY, NE
[email protected]

Frank Prioli

toll free (800) 246-2610
voice (727) 392-4761
fax (727) 320-0509
FL, GA, AL, MS, TN, NC,
SC, VA
[email protected]

Joe Parkinson

toll free (800) 952-4914
voice (909) 598-5110
fax (909) 598-3120
CA, AZ, NV, UT, HI, AK
[email protected]

Ed Bryant

voice (903) 725-7229
fax (903) 725-7863
TX, OK, AR,
LA, NM, KS, CO
[email protected]

CONTACT US

Federal Sales Manager

Walter Patenaude

(Nashua Main Office Numbers)

direct voice (603) 546-2161
cell (413) 454-3651
[email protected]

International Sales Manager

Dana Crawford

(Nashua Main Office Numbers)

direct voice (603) 546-2110
cell (508) 320-7225
[email protected]

Содержание Palladium Pd-TX-100

Страница 1: ...COFDM Transmitter Model Pd TX 100 100 mW Output Model Pd TX 250 250 mW Output DTC COMMUNICATIONS INCORPORATED...

Страница 2: ...transmitted transcribed stored in a retrieval system or translated into any language or computer language in any form or by any means including but not limited to electronic magnetic mechanical optica...

Страница 3: ...ody of the user or nearby persons NOTE This device is for occupational use only Occupational users are those persons who are exposed as a consequence of their employment provided these persons are ful...

Страница 4: ...in PAL or NTSC to the Multi I O cable BNC connector b Apply the necessary power to your camera and turn ON c Attach a 12 VDC power source such as the supplied battery pack or the AC power adapter to...

Страница 5: ...rmation on channel settings When you change the channel configuration the RF transmission is automatically switched OFF to prevent accidental interference When you have selected the channel you need p...

Страница 6: ...a 100 mW RF power output This unit is ideal for concealments and shorter range robotic and UAV applications The package is only 7 5 x 2 5 x 0 75 Power consumption is 6 Watts All connections are conven...

Страница 7: ...r See the Quick Start pages 4 5 and Heatsinking page 8 for more installation guidance Changing your Transmitter Configuration The Palladium Transmitter can store up to 8 different configurations which...

Страница 8: ...ut a heatsink has been observed to have a baseplate operating temperature of 40o C 104o F The Palladium 100 has been observed to have a baseplate operating temperature of 37o C 99o F in a similar test...

Страница 9: ...alladium Transmitter Muiti I O Connector 6 pin Hirose This connector provides connections for the DC power input programming and 75 Ohm composite video signal ALARM LED This red LED indicates a valid...

Страница 10: ...part can be used Installation of the two control programs is as simple as copying them from the CD to a suitable location on the PC No install shield routine is launched Note that the controllers gen...

Страница 11: ...tion Modulation FEC The default FEC is 2 3 however improved range operation can be achieved by selecting FEC 1 3 FEC 1 3 will improve signal range by 3dB However FEC 1 3 reduces link capacity to 1 2Mb...

Страница 12: ...ntrol is automatic Horizontal resolution The video coding resolution can be selected from 704 528 480 and 352 pixels Changing the horizontal resolution to lower values will make the coded picture soft...

Страница 13: ...of gain can be applied for microphone inputs Unit Name Future Use Sleep Mode This control allows the unit to be forced into a Sleep Mode where main functions are disabled and the power consumption is...

Страница 14: ...g Options Write AES key The key is 128 bits and is entered as 32 ASCII hexadecimal characters 0 9 and A F Video Locked Status Only This status information indicates whether the transmitter is successf...

Страница 15: ...drop RS 485 bus for control purposes Write AES Key opens a dialogue box for entering a 128bit AES scrambling key as 32 ASCII hexadecimal characters 0 F Restore Defaults restores factory default setti...

Страница 16: ...ional 6 5 W Sleep Mode 0 5 W Pd TX 250 Fully Operational 10 W Sleep Mode 0 5 W Control PC Control Interface RS 232 Memory Ten user programmable configurations Video Encoding Compression Standard MPEG...

Страница 17: ...L Specification Rec ITU R BT 470 4 Connector Hirose Composite PAL and NTSC decoding Eight bit comb filtering composite decoder Analog Audio Analog Audio Input 10 dBu Nominal Level 4 dBu Data Baud Rate...

Страница 18: ...f such products shall disclose to its satisfaction that such defects exist and have not been caused by misuse misapplication neglect improper installation improper storage alteration physical damage o...

Страница 19: ...Rich toll free 888 819 8570 voice 860 626 8570 fax 860 626 8571 NY MA CT RI PA NJ MD DE WV DC hrich dtccom com Floyd Flowers voice 208 667 5197 fax 208 676 8107 WA OR ID MT ND WY SD Gary Nichols toll...

Страница 20: ...486 Amherst Street Nashua New Hampshire 03063 603 880 4411 www dtccom com...

Отзывы: