3. Attention:
3.1 Low-battery indicate: when the battery energy is below 7V, the low-battery LED in crystal board will flash
once a second and you should replace the battery;
3.2 Avoid installing the unit on metal base;
3.3 Avoid installing the unit where sun shine or temperature change obviously, for example: air conditioning,
heater etc.
DOOR MAGNETISM
1. install magnetism and emitter on upright position of door lock, the
distance between them is 3mm~5mm and triangle on emitter aim at
triangle on magnetism(like right figure);
2. install DC12V battery into emitter;
3. press fortify key on 4-key remote controller, set general controller on
fortify state;
4. Open door, the emitter is triggered and its LED light, then emit signal
to general controller, the general controller alarm, provided that its
corresponding channel is channel 5, the Ch5 should light.
5. Tamper design: Under the condition that the triangle on emitter aim at triangle on magnetism, when emitter’s
battery lid is removed, it will emit signal and its LED light.
6.
Attention: the magnetism should be on the left of the emitter(like following figure).
THE SYSTEM CONFIGURATION
Basic
configuration
General controller*1
doorbell remote controller*1 4-key remote controller*1 DPS-55 PIR detector*1 door magnetism*1
The units for your
choosing at will
Wire detector:
D O O R
D O O R F R A M E
D O O R L O C K
695
PIR detector
TK-5
glass-break detector
DDT-15 glass-break&
PIR detector
double detector
Inc o rre c t p o sitio n
C o rre c t p o sitio n