background image

 

 
 

3. Attention: 

3.1  Low-battery indicate: when the battery energy is below 7V, the low-battery LED in crystal board will flash 

once a second and you should replace the battery;   

3.2  Avoid installing the unit on metal base; 

3.3  Avoid installing the unit where sun shine or temperature change obviously, for example: air conditioning, 

heater etc. 

DOOR MAGNETISM 

1.  install magnetism and emitter on upright position of door lock, the 

distance between them is 3mm~5mm and triangle on emitter aim at 

triangle on magnetism(like right figure); 

2.  install DC12V battery into emitter; 

3.    press fortify key on 4-key remote controller, set general controller on 

fortify state; 

4.  Open door, the emitter is triggered and its LED light, then emit signal 

to general controller, the general controller alarm, provided that its 

corresponding channel is channel 5, the Ch5 should light.   

5.  Tamper design: Under the condition that the triangle on emitter aim at triangle on magnetism, when emitter’s 

battery lid is removed, it will emit signal and its LED light. 

6. 

Attention: the magnetism should be on the left of the emitter(like following figure). 

 
 
 
 
 
 
 
 
 
 

THE SYSTEM CONFIGURATION 

 

Basic 

configuration 

 
 
 
 
 

 

General controller*1   

doorbell remote controller*1        4-key remote controller*1      DPS-55 PIR detector*1        door magnetism*1 

 

The units for your 

choosing at will 

Wire detector: 

 
 

 
 

D O O R

D O O R   F R A M E

D O O R   L O C K

695

PIR detector

 

TK-5 

glass-break detector

 

DDT-15 glass-break&

PIR detector

 

double detector 

Inc o rre c t  p o sitio n

C o rre c t p o sitio n

Содержание DSW01

Страница 1: ...smoke alarm with RF dial number equipment etc 14 working LEDs Ch1 Ch4 red wireless detector channel LED Ch5 Ch6 red both wireless and wire detector channel LED Fortify green fortify LED Low battery green battery low voltage LED Power LED Panic key green out power LED when out power is connected it lights At the same time the key is panic key press the key the general controller give panic alarm SU...

Страница 2: ...annels the correspondinng indicator separately is Ch5 and Ch6 NOTE if CN5 or CN6 is not connected general controller will alarm and corresponding channel LED Ch5 or Ch6 will light so when no wire detector connected CN5 and CN6 shoud be short connected avoiding unwanted alarm 2 3 install 6 AA batteries into battery container according to right polarity 2 4 plug power adapter into power socket power...

Страница 3: ...ce again the sensor emit signal again 1 2 Sense twice to emit sense twice the sensor emit signal 15S later after it emit signal sense twice again the sensor emit signal again This setting enhance its preventing false alarm and preventing pet function 2 test 2 1 press the fortify key on 4 key remote controller set the general controller on fortify state 2 2 set the jumper on needed position 2 3 ins...

Страница 4: ...y state 4 Open door the emitter is triggered and its LED light then emit signal to general controller the general controller alarm provided that its corresponding channel is channel 5 the Ch5 should light 5 Tamper design Under the condition that the triangle on emitter aim at triangle on magnetism when emitter s battery lid is removed it will emit signal and its LED light 6 Attention the magnetism...

Страница 5: ...wireless detector wire or wireless detector DSW 98A Smoke detector Smoke detector TK 9 PIR detector ...

Отзывы: