background image

 

 
 

 

the connection line between wire detector and general controller should not exceed 3m, and should 

install detector out of the way.   

 

 

 

 

 

 

 

DOORBELL REMOTE 
CONTROLLER 

1. operation: install it out of the door and use it as remote control doorbell, press the key, 

general controller will give Dingdong Dingdong to remind host open door. It can not 

operate other function of the general controller.   

2

Attention: avoid installing the unit on metal base. 

 

4-KEY REMOTE CONTROLLER 

1

operation 

1.1    press the panic alarm key, general controller will give panic alarm and the 8 LEDs on 

the left and light all light. 

1.2 press time-delay fortify key, general controller will give DI

DI

……

, Fortify LED flash once a second, after 60s, it give DI DI DI 

then sound stop, it enter fortify state, Fortify LED flash once 2s. 

1.3    press quick fortify key, general controller give DI and it enter 

fortify state, Fortify LED flash once 2s. 

1.4    press cancel key, you can cancel above operation, general 

controller give DI DI, that indicate operation has been canceled. 

2

  Attention: avoid installing the unit on metal base. 

 

 WI

RELESS DETECTOR DPS-55 

1

Jumper setting (like right 

figure) 

1.1 Sense once to emit: 

sense once, the sensor emit 

signal , 15S later after it emit 

signal, sense once again, the 

sensor emit signal again. 

1.2 Sense twice to emit: 

sense twice, the sensor emit signal , 15S later after it emit signal, 

sense twice again, the sensor emit signal again. 

This setting 

enhance its preventing false-alarm and preventing-pet 

function. 

 

2. test   

2.1 press the fortify key on 4-key remote controller, set the general controller on fortify state. 

2.2 set the jumper on needed position; 

2.3 install 9V battery, after 60s the sensor enter stable working state;     

2.4 move along the tangent of the lens, sense it, the sense LED light and then it emit signal to general controller, the 

emission LED light; 

2.5 after receiving emission signal, general controller give alarm(>90db), the alarm time delay is 3Min 30s, provided 

that its corresponding channel is channel 3, the Ch3 should light(press cancel key on 4-key remote controller to stop 

alarm quickly). 

EMISSION 
LED

BATTERY 
COVER

PANIC ALARM

TIME-DELAY FORTIFY
QUICK FORTIFY
CANCEL

4-KEY REMOTE CONTROLLER

EMISSION LED

EMISSION KEY

DOORBELL REMOTE CONTROLLER

BOTTOM COVER

INSTALLING HOLE

INSTALLING HOLE

CROSSING-LINE 
HIDDEN HOLE

INSTALLING HOLE

INSTALLING HOLE

CROSSING-LINE 
HIDDEN HOLE

PRESS HIDDEN HOLE WITH POWER TO OPEN

BOTTOM COVER FIGURE(BACK)

2

3

OPEN FRONT COVER FIGURE

FRONT COVER

TIGHTEN OFF 
SCREW

1

PUSH BACK THE 
FRONT FCOVER

PULL UP THE 
FRONT COVER

AUTO

DIP switch

Sense LED

PIR

Jumper

AUTO / 1

AUTO / 1

1

Emit LED

Sense 
once to 
emit

Sense 
twice to 
emit

Low-battery LED

Содержание DSW01

Страница 1: ...smoke alarm with RF dial number equipment etc 14 working LEDs Ch1 Ch4 red wireless detector channel LED Ch5 Ch6 red both wireless and wire detector channel LED Fortify green fortify LED Low battery green battery low voltage LED Power LED Panic key green out power LED when out power is connected it lights At the same time the key is panic key press the key the general controller give panic alarm SU...

Страница 2: ...annels the correspondinng indicator separately is Ch5 and Ch6 NOTE if CN5 or CN6 is not connected general controller will alarm and corresponding channel LED Ch5 or Ch6 will light so when no wire detector connected CN5 and CN6 shoud be short connected avoiding unwanted alarm 2 3 install 6 AA batteries into battery container according to right polarity 2 4 plug power adapter into power socket power...

Страница 3: ...ce again the sensor emit signal again 1 2 Sense twice to emit sense twice the sensor emit signal 15S later after it emit signal sense twice again the sensor emit signal again This setting enhance its preventing false alarm and preventing pet function 2 test 2 1 press the fortify key on 4 key remote controller set the general controller on fortify state 2 2 set the jumper on needed position 2 3 ins...

Страница 4: ...y state 4 Open door the emitter is triggered and its LED light then emit signal to general controller the general controller alarm provided that its corresponding channel is channel 5 the Ch5 should light 5 Tamper design Under the condition that the triangle on emitter aim at triangle on magnetism when emitter s battery lid is removed it will emit signal and its LED light 6 Attention the magnetism...

Страница 5: ...wireless detector wire or wireless detector DSW 98A Smoke detector Smoke detector TK 9 PIR detector ...