7. panic alarm: 

when danger occur in your home, you can prees the panic key to give panic asking for help 

signal to neighbor or others and obtain other’s help.   

8. alarm memory:

 on fortify state, when host isn’t at home there is person enter detection field, general controller 

alarm, after the alarm stops, the corresponding LED still light to indicate that channel ever had danger, only after 

using remote controller to reset, the LED will be off. 

 

GENERAL CONTROLLER 

1

Connection-wire figure:

 

1.1. terminal 1&2: output voltage, connect 1 

with “-“,connect 2 with “+“; 

1.2. 

terminal 3&4 can connect with wire 

detector, is 5

th

 channel CN5, 

corresponding indicator is Ch5; 

1.3. 

terminal 5&6 can connect with wire 

detector, is 6

th

 channel CN6, 

corresponding indicator is Ch6; 

1.4. terminal 7&8: alarm output, when it alarm, 

other alarm connected with it also 

alarm,7connect with “-“, 8 with “+”; 

1.5. terminal 9&10: other output; 

1.6. terminal 11&12 input voltage , connect 11 

with “-“, connect 12 with “+“. 

2

operation 

2.1 install detector on selected position; 

2.2 connect wire according to connection-wire 

figure: connect “-” and “+” of power adapter to 

terminal 11&12, and the polarity can not be 

connected oppositely, connect CN5 and CN6 with 

wire detector, they are two wire channels, the  

correspondinng indicator separately is Ch5 and Ch6, 

NOTE: if CN5 or CN6 is not connected, general controller 

will alarm and corresponding channel LED (Ch5 or Ch6) will light, so when no wire detector connected, CN5 

and CN6 shoud be short connected avoiding unwanted alarm; 

2.3 install 6 AA batteries into battery container according to right polarity; 

2.4 plug power adapter into power socket, power LED should light, Fortify and Low-battery LEDs flash once 0.5 

second, after 60s, general controller give one DI sound, Fortify LED flashes once 2s and Low-batter4y LED stop 

flashing and remain on.

 

NOTE: during this 60s, any operation is not effect. 

2.5 

close front cover. 

NOTE: after power is on, there is 60s to wait you close front cover avoiding tamper 

alarm.

 

2.6 press the panic key on general controller, it give panic alarm and all LEDs light, the alarm time is 3Min 30s(press 

the cancel key on 4-key remote controller to stop alarming quickly); 

2.7  press fortify key on 4-key remote controller, set general controller on fortify state; 

2.8    test every detector one by one, when wire detector work, general controller alarm, the alarm time is 3Min 30s, 

the corresponding channel LED

Ch5 or Ch6

should light. When wireless detector work, general controller 

should alarm, alarm time is 3Min 30s, corresponding channel LED

Ch1 or Ch2

3

4

5

6

should light. 

3. attention: 

 

avoid installing the unit on metal base; 

 

when general controller alarming, the sound is very high, so when alarm occur, you should eliminate it in 

time avoiding affecting others. 

 

if power adapter need replacing, the replacing adapter’s standard should be: input  voltage 

110VAC/230VAC, output voltage 10~12V/DC, current 1A. suggest you contacts with supplier and use original 

adapter.   

 

if the power adapter is connected oppositely, the unit will not work, but it will not be damaged; 

 

Содержание DSW01

Страница 1: ...smoke alarm with RF dial number equipment etc 14 working LEDs Ch1 Ch4 red wireless detector channel LED Ch5 Ch6 red both wireless and wire detector channel LED Fortify green fortify LED Low battery green battery low voltage LED Power LED Panic key green out power LED when out power is connected it lights At the same time the key is panic key press the key the general controller give panic alarm SU...

Страница 2: ...annels the correspondinng indicator separately is Ch5 and Ch6 NOTE if CN5 or CN6 is not connected general controller will alarm and corresponding channel LED Ch5 or Ch6 will light so when no wire detector connected CN5 and CN6 shoud be short connected avoiding unwanted alarm 2 3 install 6 AA batteries into battery container according to right polarity 2 4 plug power adapter into power socket power...

Страница 3: ...ce again the sensor emit signal again 1 2 Sense twice to emit sense twice the sensor emit signal 15S later after it emit signal sense twice again the sensor emit signal again This setting enhance its preventing false alarm and preventing pet function 2 test 2 1 press the fortify key on 4 key remote controller set the general controller on fortify state 2 2 set the jumper on needed position 2 3 ins...

Страница 4: ...y state 4 Open door the emitter is triggered and its LED light then emit signal to general controller the general controller alarm provided that its corresponding channel is channel 5 the Ch5 should light 5 Tamper design Under the condition that the triangle on emitter aim at triangle on magnetism when emitter s battery lid is removed it will emit signal and its LED light 6 Attention the magnetism...

Страница 5: ...wireless detector wire or wireless detector DSW 98A Smoke detector Smoke detector TK 9 PIR detector ...

Отзывы: