SPECIFICATION 

1  voltage

power adapter convert

:110VAC          230VAC 

2  standby power:9V/DC

6

×

AA

 

3  operate frequency: 433MHz        315 MHz 

4    operate channel:6(wireless channel has 6, 2 of 6 are also wire channels)   

5    alarm method:sound and light alarm indicator 

6  alarm current:150mA 

7    out power static current: 26 mA   

8    standby power static current:16 mA(when out power cut)   

9  alarm time:3Min 30seconds 

10  alarm sonority:90db 

11  remote control distance: 

30m( wide place) 

12 

battery low-voltage alarm:7.5V~7.9V

 

13  the system include unit: general controller(with power adapter)

single doorbell remote controller(battery 

included) 

4-key remote controller(battery included) 

power adapter(input voltage 110VAC/230VAC, output voltage 

10~12V/DC, current 1A) 

DPS-55 PIR detector(battery included)

door 

magnetism(battery included). The unit for choosen: other type detector

smoke alarm with RF

dial number equipment etc.   

14  working LEDs: 

Ch1~Ch4: red, wireless detector channel LED; 

Ch5~Ch6: red, both wireless and wire detector channel LED

 

Fortify: green, fortify LED

 

Low-battery: green, battery low-voltage LED

 

Power LED&Panic key: green, out power LED. when out power is 

connected, it lights. At the same time, the key is panic key, press 

the key, the general controller give panic alarm. 

 

SUMMARY 

1. channel indicate:

 when detector working, general controller 

alarm and corresponding channel LED should light. 

2. low-voltage indicate: 

when standby power is below set value, cut off out power, you can see Low-battery LED 

flashing and remind you to replace battery in time. 

3. tamper protection:

 when front cover is opened, general controller will give alarm, the 8 LEDs on the left and   

right all flash.   

4. two remote controllers:   

z

 

single-key doorbell remote controller: power voltage DC12V, it can be installed out of the door and 

used as remote control doorbell; 

z

 

4-key remote controller: power voltage DC12V, it is used for panic alarm, time-delay fortify, quick fortify, 

cancel.  

5. fortify:

 when host leave home, use remote controller to set general controller on fortify state, when someone 

enter its detection field, general controller will give alarm (>90db), if connect dial number implement of our company, 

general controller will also give alarm weft, for example 110 or your home’s telephone.   

6. cancel: 

after host come back home and cancel the general controller’s fortify state, when host enter detection 

field, the general controller will not alarm. 

Ch6

Ch5

Low-battery

Fortify

Power LED&Panic key

Ch4

Ch3

Ch1

Ch2

GENERAL CONTROLLER

Содержание DSW01

Страница 1: ...smoke alarm with RF dial number equipment etc 14 working LEDs Ch1 Ch4 red wireless detector channel LED Ch5 Ch6 red both wireless and wire detector channel LED Fortify green fortify LED Low battery green battery low voltage LED Power LED Panic key green out power LED when out power is connected it lights At the same time the key is panic key press the key the general controller give panic alarm SU...

Страница 2: ...annels the correspondinng indicator separately is Ch5 and Ch6 NOTE if CN5 or CN6 is not connected general controller will alarm and corresponding channel LED Ch5 or Ch6 will light so when no wire detector connected CN5 and CN6 shoud be short connected avoiding unwanted alarm 2 3 install 6 AA batteries into battery container according to right polarity 2 4 plug power adapter into power socket power...

Страница 3: ...ce again the sensor emit signal again 1 2 Sense twice to emit sense twice the sensor emit signal 15S later after it emit signal sense twice again the sensor emit signal again This setting enhance its preventing false alarm and preventing pet function 2 test 2 1 press the fortify key on 4 key remote controller set the general controller on fortify state 2 2 set the jumper on needed position 2 3 ins...

Страница 4: ...y state 4 Open door the emitter is triggered and its LED light then emit signal to general controller the general controller alarm provided that its corresponding channel is channel 5 the Ch5 should light 5 Tamper design Under the condition that the triangle on emitter aim at triangle on magnetism when emitter s battery lid is removed it will emit signal and its LED light 6 Attention the magnetism...

Страница 5: ...wireless detector wire or wireless detector DSW 98A Smoke detector Smoke detector TK 9 PIR detector ...

Отзывы: