background image

*                        *                                                         

                                                  Network Public Address System

 

Network Display terminal                                                                                                                           

POE6401 

II. Description of the external appearance 

 

2.1 Introduction of the front panel 

 

 

1  Digital  display  screen  and  infrared  remote 

control receiving window 

The  digital  display  screen  indicates  the  working 
state and network information state of the machine. 
The  infrared  remote  controller  is  inserted  at  the 
upper  right  corner  of  the  display  screen,  and  the 
machine  state  can  be  controlled  with  the  infrared 
remote control. 

2

 

STBY 

The standby function indicator lamp is equal to the 
mute  function,  and  the  network  alarm  and 
emergency  signal  can  open  it.  That  is  to  say,  the 
alarm  and  emergency  signal  can  cancel  the  mute 
state. 

3

 

Net Service 

When  the  machine  and  the  host  machine  are 
successfully  connected  through  the  network,  the 
indicator lamp is on. 

4 Timing 

The  terminal  can  be  separated  from  the  host 

machine  to  implement  the  timing  point  edited. 
When  the  terminal  can  be  separated  from  the  host 
machine  to  implement  the  timing  point,  the 
indicator lamp is on. 

5 Signals 

When the signal is output  from the terminal  power 
amplifier, the indicator lamp is on. When the power 
amplifier  volume  is  gradually  increased,  the 
indicator  lamp  is  brightened  gradually;  when  the 
volume is gradually decreased, the indicator lamp is 
darkened gradually. 

6 Screw fixing hole 

        The  terminal  can  be  installed  at  the  positions 

similar to the wall. There are 4 fixed screw holes 
on  the  machine, and  the  machine  is  fixed on  the 
wall surface with the with-machine screws during 
installation. 

7 Play / pause key 

        When  the  local  MP3  program  is  played,  the  key 

is used to conduct play / pause operation; during 

address  settings,  the  key  is  used  to  save  setting 

Содержание POE6401

Страница 1: ...L STBY Net Service Timing Signal P L A Y Network Terminal POE6401 User Manual Thank you for using our DSPPA public address system Please read this User Manual carefully to make better use of this equi...

Страница 2: ...nical indicators of the product and other contents of the four way network public address terminal Prior to connection installation and use the user shall carefully read the instructions and conduct o...

Страница 3: ...th the power grid The power cord plug shall be unplugged from the power socket for safety when the equipment is not used Laying position Please disconnect the power supply prior to movement of the equ...

Страница 4: ...nt electric shock Please do not try to disassemble internal parts of the equipment or conduct transformation of any form In case of any anomaly please immediately stop use and invite the professionals...

Страница 5: ...ternal appearance 2 2 1 Introduction of the front panel 2 2 2 Introduction of the side panel 3 2 3 Instructions for remote controller structure 4 III Connection legend 6 3 1 Schematic diagram of appli...

Страница 6: ...wer amplifiers so as to expand the power there is a way microphone interface so as to realize local paging and so on 1 2 Performance features It can work across the network segments It can be coupled...

Страница 7: ...successfully connected through the network the indicator lamp is on 4 Timing The terminal can be separated from the host machine to implement the timing point edited When the terminal can be separated...

Страница 8: ...the viewed parameters Set IP mode parameter plus minus function 14 VOL key Play mode volume up function View IP mode switch and select the viewed parameters Set IP mode parameter plus minus function 2...

Страница 9: ...the terminal power 11 MIC2 interface Connect the microphone to realize local paging site talking and other functions Not opened to the machine 12 Power amplifier cooling window 13 Power POWER Press I...

Страница 10: ...the terminal 11 F3 IP address view modification key Press it to enter view state press CH CH to select the parameter to the view press F3 to enter the setting state and press Enter for saving after mo...

Страница 11: ...he machine a way auxiliary input and a way auxiliary output are also arranged to connect other audio sources and power amplifiers The customized design can satisfy demands for high power and multiple...

Страница 12: ...e connection of the machine is shown in the following figure The power amplifier is 2 10W output note please adopt two way simultaneous output with caution due to POE switch supply power restrictions...

Страница 13: ...switches to display the corresponding parameter value c At the moment press Set key to enter IP address modification state When the parameter flashes press key or key to switch the parameter bit press...

Страница 14: ...not place any corrosive chemical near or on the equipment 2 Precautions for after sales service Our company will offer three year free warranty including provision and replacement of parts for free f...

Страница 15: ...k display terminal 1 set 2 1500MM dual modem audio cable 1 piece 3 3000MM 8 core network cable 1 piece 4 Instructions 1 copy 5 Guarantee card 1 copy 6 Conformity certificate 1 copy 7 7P green plug 3 8...

Страница 16: ...fier Independent channel mode 10W 4 Maximum harmonic distortion of the built in power amplifier 0 3 MIC microphone input Input sensitivity 10 mV Frequency response 20Hz 20kHz Distortion 0 5 Noise 2 mV...

Страница 17: ...plate at discretion so as to prevent electric shock The professional with professional certificate shall conduct repair if necessary The terminal marked with symbol in the equipment represents hazard...

Отзывы: