background image

 

AD1200 Installer Manual, Rev. 19.06.2013                                     1                                                               

www.dsp-technology.com

 

Introduction 

Features 
Technical Specifications 
Installation 
Wiring Terminals 
Wiring Diagram AD1200 - ST6100, ST6500 & ST6600 
 

Installer Programming 

Enter Installer Programming Code 
Programming New Installer Code 

 

Recall New Installer Code 
Burn In Installer Code 
Setting Pulse or Tone Dialling 
Operating Through PABX 

       

IMPROVED FEATURE

 

Deleting PABX Line Extension Number 

        

Programming Audible Alert After Alarm Dialling 
Programming Dial Cycles 

              

NEW FEATURE

 

Programming Alarm Input 
Programming Entry Exit Timing 

              

NEW FEATURE

 

Entering Telephone Numbers 

         

IMPROVED FEATURE    

 

Programming Slow Dialling Telephone Numbers 
Recall Entered Telephone Numbers 
Deleting A Telephone  
Deleting All Telephone Numbers 
Recording Voice Message 
Exit Installer Programming 
Enter Installer Test Mode 
Exit Installer Test Mode 
Enabling and Disabling of Remote Device Functionality    

NEW FEATURE

 

Recording and new Remote Device     

            

NEW FEATURE 

Deleting a Remote Device     

            

NEW FEATURE 

Deleting all eight Remote Devices     

            

NEW FEATURE 

Setting Remote Device Type     

            

NEW FEATURE

 

Reset All Programmable Locations to Factory Default 
Hardware Reset to Factory Default Settings 
 

User Mode / User Programming 

Entering User Programming 
Change User Code 
Change Telephone Number  No.1 
Display Telephone Number  No.1 
Exit User Programming and Arming the System 
 

User Operation 

Switching Off or Switching to Standby Mode 
Activating Silent Alarm          

       

IMPROVED FEATURE    

 

Alarm Memory 
Reset Alarm Memory 
 

Installation Programming Notes

 

 

                                              CONTENTS                              ENGLISH 

1.00 

1.01 
1.02 
1.03 
1.04 
1.05 
 

2.00 

2.01 
2.02 
2.03 
2.04 
2.05 
2.06 
2.07 
2.08 
2.09 
2.10 
2.11 
2.12 
2.13 
2.14 
2.15 
2.16 
2.17 
2.18 
2.19 
2.20 
2.21 
2.22 
2.23 
2.24 
2.25 
2.26 
2.27 
 

3.00 

3.01 
3.02 
3.03 
3.04 
3.05 
 

4.00 

4.01 
4.02 
4.03 
4.04 
 

5.00

 

  2 

  2 
  2 
  2 
  3 
  3 
 

  4 

  4 
  4 
  4 
  4 
  4 
  4 
  4 
  5 
  5 
  5 
  5 
  6 
  6 
  6 
  6 
  6 
  6 
  6 
  7 
  7 
  7 
  7 
  7 
  7 
  8 
  8 
  8 
 

  9 

  9 
  9 
  9 
  9 
  9 
 

 10 

 10 
 10 
 10 
 10 
 

 11 

 

Section 

Page No. 

Содержание AD1200

Страница 1: ...AD1200 ...

Страница 2: ...ller Test Mode Enabling and Disabling of Remote Device Functionality NEW FEATURE Recording and new Remote Device NEW FEATURE Deleting a Remote Device NEW FEATURE Deleting all eight Remote Devices NEW FEATURE Setting Remote Device Type NEW FEATURE Reset All Programmable Locations to Factory Default Hardware Reset to Factory Default Settings User Mode User Programming Entering User Programming Chang...

Страница 3: ...nd voice data are saved Performs tone pulse and also through PABX system dialling with multiple attempts Telephone numbers programmed can be recalled for display Programmable telephone delay time for each telephone number Single voice message up to 20 seconds and programmable Entry Exit Timing Lightning protection at telephone line input Optional Remote Device functionality for Panic Alarm Arming ...

Страница 4: ...d Set Telephone Hand Set Green Set Telephone Hand Set Red ST6100 ST6600 ST6000 ST6500 other Panels 12V 12V 12V 12V INP INP SET SET SET SET LINE LINE LINE LINE AUX 1 S AUX S BELL EARTH EARTH Note If you are not using the S on the ST6100 ST6600 you can enter engineer programming in those control panels and change the Switch Positive to 0V If a secure zone is activated in the ST6100 or ST6600 the Dia...

Страница 5: ...tarts blinking you are now in installer programming mode 2 02 Programming New Installer Code Press Enter new 4 digit code 2 03 Recall New Installer Code Press 2 04 Burn In Installer Code 2 05 Setting Pulse or Tone Dialling Press 2 06 Operating Through PABX If the AD1200 has to call through a PABX system Program in this location the telephone number which obtains an outside line The dialer will wai...

Страница 6: ...e default Programming values from 1 9 correspond to Entry Exit Times of 10 90 seconds PROG 0 5 Press If an Entry Exit time greater than 0 is programmed then the system will act as following 1 After the user leaves the User Mode the system will start the Exit Timer The system indicates the user with beeps that he should leave the premises Within this time any signal from the input is masked No dial...

Страница 7: ...Telephone Numbers Programmed telephone numbers can be recalled and displayed on the seven segment display Press READ PROG Enter telephone number location 2 15 Deleting A Telephone Number Press PROG Enter telephone number location ENTER 2 16 Deleting All Telephone Numbers Press PROG 1 9 Press 2 17 Recording Voice Message The voice message recoding duration is 20 seconds The microphone is located be...

Страница 8: ...e device and link it to the AD1200 Note If the selected location already contains another Remote Device the current location must be deleted first refer to 2 23 before linking a new device is possible at this location Press Press 2 23 Deleting a Remote Device To delete a Remote Device follow the following procedure 2 24 Deleting all eight Remote Devices Press PROG 0 8 1 To disable the feature the ...

Страница 9: ...ll invalidate you warranty Every effort has been made to provide accurate information however slight variations can occur We reserve the right to make changes for the product improvement at anytime 2 25 Setting Remote Device Type Each of the eight Remote Devices may be setup to one of the following different functionalities Remote Panic Button Type Code 1 Remote Arming Type Code 2 Remote Disarming...

Страница 10: ... ENTER PWR LED extinguished Programming can only be done when the unit is in off mode This is indicated by the PWR LED extinguished The dialer will exit user programming if no data entering after 2 minutes If the PWR LED is on after entering user code re enter the user code again Acceptance of programming is given by 6 short beeps from the buzzer error tone is indicted by a long beep Enter new tel...

Страница 11: ... activated Off mode is indicated by the PWR LED extinguished 4 02 Activating Silent Alarm operational in Standby as well as in Off Mode Enter user code ENTER Power LED extinguished You can return to standby mode by repeated above sequence 4 01 Switching Off or Switching to Standby Mode Press PROG ENTER simultaneous to activate Silent Alarm Panic Alarm 4 03 Alarm Memory If AD1200 has activated in S...

Страница 12: ...n Number Clear Installer Code Burn In Clear Dialer Memory Audible Disabled Alarm Trigger Input 12 Volts Telephone No 1 Clear Telephone No 2 Clear Telephone No 3 Clear Telephone No 4 Clear Telephone No 5 Clear Telephone No 6 Clear Telephone No 7 Clear Telephone No 8 Clear Slow Dialing Telephone Num Clear Dial Cycles 2 Entry Exit Time 0 OFF Recorded Message Installer Information Installer Name Addre...

Отзывы: