DSC TR5164-433 Скачать руководство пользователя страница 7

5

Section 2: TR5164 Set Up & Wiring

This section describes how to set up and wire the TR5164 module.

2.1 Unpack the TR5164

Check that the following parts are in the package:

• TR5164 PCB

• Hardware for mounting the cabinet

• TR5164 plastic cabinet

2.2 Choose a Mounting Location for the TR5164

NOTE: 

Permanently mount the TR5164 receiver and wireless devices after placement testing 

each device (

Section 5.1, page 11

).

Find a place that is:

• Dry

• Within operating temperature range

• Central to the proposed placement of all wireless devices

• As high as possible

• Far from sources of interference, including: electrical noise (computers, televisions and electric 

motors in appliances and heating and air conditioning units), large metal objects like heating ducts 

and plumbing which may shield the electro-magnetic waves. 

For proper unit tamper operation, the surface that the TR5164 is mounted to should be smooth and 

free of obstructions that block access to the rear of the unit.

Ensure that electrical wires do not run over and under the module when it is mounted.

When mounting the TR5164 in a basement, place the module as high and as close to the underside of 

the first floor as possible. The range of the module is reduced if mounted below ground level.

2.3 Connect the TR5164 

Receiver 

CAUTION: Remove all power (AC, DC, telephone 

lines) from the system while connecting modules to 

the Keybus.

KEYBUS 

TO TR5164

Connect the TR5164 to the four-wire Keybus of the 

control panel according to the diagram.

NOTE: 

Do not use the terminal labeled “GND.”

Once the wiring is complete, reconnect power to the 

security system.

Next, enroll and program the wireless devices. See 

Section 3.2, page 6

 for instructions.

2.4 Tamper

The unit incorporates separate built-in wall and case tampers. The tampers are disabled by default on 

the NA version (enabled on EU version). Section [804][900] options 3 and 4 enable or disable the 

tampers.

When the TR5164 is properly installed, the wall tamper on the back of the unit should be depressed 

by the mounting surface. If the unit is removed, the tamper activates. The case tamper activates when 

the case is opened and restores when the case is closed.

NOTE: 

The built in wall and case tamper must be installed and enabled for UL/ULC Listed 

Commercial Burglary applications.

DRAFT

Содержание TR5164-433

Страница 1: ...limitaciones conrelaci n al uso y funcionamiento del producto e informaci n acerca de las limitaciones como la responsabilidad del fabricante Importante Questo manuale contiene informazioni sulle limi...

Страница 2: ...t properly alert occu pants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detecto...

Страница 3: ...dversely affect per formance or prevent adequate inspection or testing to verify any warranty claim Access cards or tags returned for replacement under warranty will be credited or replaced at DSC s o...

Страница 4: ...ARE PRODUCT may only be used with the HARDWARE as set forth in this EULA d Rental You may not rent lease or lend the SOFTWARE PRODUCT You may not make it available to others or post it on a server or...

Страница 5: ...e zone and other programming on the system Section 4 1 page 8 4 Test the placement of all the wireless devices Section 5 1 page 11 5 Permanently mount the TR5164 receiver and wireless devices Section...

Страница 6: ...technical training and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other persons It mus...

Страница 7: ...s mounted When mounting the TR5164 in a basement place the module as high and as close to the underside of the first floor as possible The range of the module is reduced if mounted below ground level...

Страница 8: ...d 3 2 Enroll the Wireless Keypad During initial power up of the alarm panel a 2 minute window is established for enrolling the wireless keypad indicated by flashing AC Power and Ready LEDs If the enro...

Страница 9: ...adecimal digits To toggle between decimal and hexadecimal values press For instructions on programming hexadecimal numbers see the system Installation Manual The device is now enrolled on the system 4...

Страница 10: ...amming section 902 Wait approximately 1 minute while the system scans for connected modules 4 To exit press The system generates a General System Supervisory trouble if the module is removed from the...

Страница 11: ...Supervision is enabled by default for all wireless zones 4 To exit press 4 4 Reporting Openings Closings by Wireless Keys Openings closings and command output activation e g opening a garage door by...

Страница 12: ...tings removes all enrolled devices from the system and resets programming in section 804 NOTE Performing this procedure does not reset any other programming sections on the control panel Likewise rese...

Страница 13: ...inches to correct a bad result Do not mount any device where a bad test result is indicated 5 Perform step 4 for each wireless device enrolled on the TR5164 Wait until the placement test of one devic...

Страница 14: ...reless devices has been tested and verified Section 5 1 page 11 mount the TR5164 as follows 1 Pull the Keybus wires through the hole at the bottom of the cabinet 2 Mount the cabinet securely to the wa...

Страница 15: ...within the time programmed for the Wireless Supervisory Window a zone fault is generated RF Delinquency EU only Each wireless zone sends a supervisory signal every 15 minutes If the receiver does not...

Страница 16: ...following see Section 5 1 page 11 for more information on testing devices Verify that the correct zone is being tested Verify that the correct ESN was entered when the device was enrolled Verify that...

Страница 17: ...4 must be enrolled into zones 29 32 respectively All other wireless devices may be enrolled into any of the remaining 60 zones Default 000000 Zone Zone Zone 001 023 044 002 024 045 003 025 046 004 02...

Страница 18: ...Zone 25 2 Zone 2 Zone 10 Zone 18 Zone 26 3 Zone 3 Zone 11 Zone 19 Zone 27 4 Zone 4 Zone 12 Zone 20 Zone 28 5 Zone 5 Zone 13 Zone 21 Zone 29 6 Zone 6 Zone 14 Zone 22 Zone 30 7 Zone 7 Zone 15 Zone 23 Zo...

Страница 19: ...ay Arm 19 7 3 Command Output 3 04 Away Arm 20 For Future Use 05 9 No Entry Arm 21 7 4 Command Output 4 06 4 Chime ON OFF 22 Global Disarm 07 6 code 4 System Test 23 26 For Future Use 08 12 For Future...

Страница 20: ...3 Default 27 Function4 Default 30 Function5 Default 13 Function6 Default 14 141 Key 1 142 Key 2 143 Key 3 144 Key 4 145 Key 5 146 Key 6 147 Key 7 148 Key 8 149 Key 9 150 Key 10 151 Key 11 152 Key 12...

Страница 21: ...13 is 2 way Key 13 is 1 way 6 Key 6 is 2 way Key 6 is 1 way 14 Key 14 is 2 way Key 14 is 1 way 7 Key 7 is 2 way Key 7 is 1 way 15 Key 15 is 2 way Key 15 is 1 way 8 Key 8 is 2 way Key 8 is 1 way 16 Ke...

Страница 22: ...less Delinquency Enabled 6 Future Use 7 RF Jam Disabled RF Jam Enabled 8 Future Use 904 Wireless Device Placement Test See Testing Individual Devices on page 11 for details 8 1 Keypad Programming Opti...

Страница 23: ...LQJXQJHQ XQG 9RUUDXVHW XQJHQ GHU 5LFKWOLQLH HQWVSULFKW 5 6 7 RQ OD SUHVHQWH OD LJLWDO 6HFXULW RQWUROV GLFKLDUD FKH TXHVWR SURGRWWR FRQIRUPH DL UHTXLVLWL HVVHQ LDOL HG DOWUH GLVSRVL LRQL ULOHYDQWL UHOD...

Отзывы: