For Your Records

Location

Test Time & Day

Additional Notes

CONNECT 24

TM

 Enrollment Information

Note: 

Only authorized dealers can enroll a wireless system to 

Connect 24.

Dealer application forms and additional information on the Connect 24 Voice 
Response Unit can be found at the Connect 24 web site.

 http://www.connect24.com/dealer.htm

The information required for activation is listed below. Ensure that all information 
is available before calling the Connect 24 Voice Response Unit.

USA 1-888-251-7458

CAN 1-888-955-5583

Profile Number ...................................................5 digits I___I___I___I___I___I

The profile number provides Central Station Receiver information.

Installer ID Number ............... 8-9 digits I___I___I___I___I___I___I___I___I___I

An Installer ID number was provided for each installer listed on the 

Dealer 

Enrollment Form

. This number can be found on the authorized 

Installer Card

 

sent with the 

Dealer Confirmation Form.

Installer PIN Number ................................................ 4 digits I___I___I___I___I

Each Installer provided a 4 digit PIN number on the 

Dealer Enrollment Form

. If 

you have forgotten your PIN Number contact 

Connect 24.

Central Station Account number ............ 2-6 digits I___I___I___I___I___I___I

This is the Account Number that will be sent to the Central Station.

NOTE:

 4-digits maximum for 

Contact ID

 format.

Skyroute MIN....................10 digits I___I___I___I___I___I___I___I___I___I___I

The Skyroute 

Mobile Identification Number 

identifies the Skyroute transmitter. 

The 10-digit MIN is located on the label affixed to your Skyroute Transmitter.

System ID Number (SID)

................................5 digits I___I___I___I___I___I

The

 System ID Number 

informs Connect 24 and the cellular network the 

home 

area 

that your transmitter is installed in. When this number is programmed into 

an alarm panel it is entered in 

HEX format. 

When entering this number into the 

Connect 24 Voice Response Unit, it is entered in 

Decimal Format.

Содержание Skyroute CL3050 ver 1.2

Страница 1: ...rSeries keypads Installation Programming Guide WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manu...

Страница 2: ...found on the authorized Installer Card sent with the Dealer Confirmation Form Installer PIN Number 4 digits I___I___I___I___I Each Installer provided a 4 digit PIN number on the Dealer Enrollment Form...

Страница 3: ...02 Zone 3 8 Definitions 9 03 Zone 1 2 Loop Response 9 10 Skyroute CL3050 Mode of Operation 9 11 Skyroute CL3050 Configuration Options 1 10 12 Skyroute CL3050 Configuration Options 2 11 13 Skyroute CL3...

Страница 4: ...ii NOTE...

Страница 5: ...rglar alarm reporting code to Connect 24 Refer to the appropriate control panel Installation Manual NOTE Not for UL Listed installations Mode 2 2 Zone Panel In Mode 2 the system will configure itself...

Страница 6: ...y all PowerSeries Keypads PC5508 KP5508Z 8 Zone LED keypad PC5516Z KP5516Z 16 Zone LED keypad PC5532Z KP5532Z 32 Zone LED keypad LCD5500Z KPL5500Z Programmable Message LCD Keypad LCD5501Z KP5501Z Fixe...

Страница 7: ...RF noise or interference Refer to section 6 Programming Descriptions section 10 for zone wir ing details NOTE Generally the higher the location and the closer that the Skyroute CL3050 is to an outsid...

Страница 8: ...tton for 2 seconds will send a test transmission to the central station via Connect 24 Refer to Enroll Button in Section 3 Controls and indicators for test transmission details Mode 1 Disable the tele...

Страница 9: ...of flashes as indicated below No of Flashes Indication 1 2 3 4 5 6 7 8 9 No trouble conditions present Low battery Input supply failure Not enrolled at Connect 24 No service available Radio failure PC...

Страница 10: ...iled RSSI status indicated above Holding this button down for a period of 2 seconds continuously will cause the Skyroute CL3050 to send a test transmission to Connect 24 this long debounce will be ind...

Страница 11: ...d it will look for a PC5108 zone expander module If a zone expander is found it will automatically configure itself for mode 3 If no Keybus modules are present the Skyroute CL3050 will power up in mod...

Страница 12: ...odes 2 3 When the Skyroute CL3050 is in Mode 2 or 3 there are 14 options that can be programmed as zone types All of the zone types with the exception of 00 null zone 13 CL3050 communications zone and...

Страница 13: ...t for any steady bell the Skyroute CL3050 will send a generic Burglary event The GRN terminal is a trouble input which can be connected to a system output to alert the Skyroute CL3050 of a system TLM...

Страница 14: ...tation NOTES This configuration can not be used with an AC supply Jumpers on the PC5108 must be set as follows J1 J2 J3 ON OFF ON J4 J5 J6 OFF OFF ON Default 01 03 dependant on start up configuration...

Страница 15: ...edure with Connect 24 IF the Skyroute CL3050 is reset to the default settings this option must be set to ON for the Skyroute CL3050 to resume communications Default Not Enrolled Options 7 8 System Use...

Страница 16: ...ith the cellular radio Default ON Option 6 PC5108 Failure Mode 3 This trouble is indicated if a PC5108 supervisory or Keybus fault occurs NOTE The PC5108 tamper is communicated only therefore it can o...

Страница 17: ...0 will randomly generate this value Because one test transmission weekly is the most common configuration this will allow the installer to setup the Skyroute CL3050 without keypad programming Option 1...

Страница 18: ...ignored until that group s timer has expired See table below for zone type grouping Zone Type Detailed Reporting Code Generic Reporting Code Null Burglary Fire Panic Technical Gas Heat Medical Emerge...

Страница 19: ...050 communications zone is violated Default OFF 22 Input Supply Fail TX Delay All Modes This value determines the delay default 0700 7 hrs before an input supply fail ure reporting code is sent if pro...

Страница 20: ...Hex 0 1 second increments mode 2 only Default Default 05 I___I___I Zone 1 05 I___I___I Zone 2 10 Skyroute CL3050 Mode of Operation Default Default 01 I___I___I 01 Bell Follower 02 2 Zone 03 8 zone PC...

Страница 21: ...N I___I 4 No Service Available Disabled ON I___I 5 Radio Failure Disabled ON I___I 6 PC5108 Failure Disabled ON I___I 7 Failure to Communicate Disabled OFF I___I 8 Skyroute CL3050 Tamper Disabled 15 S...

Страница 22: ...tores Disabled OFF I___I 5 Zone Tamper Disabled OFF I___I 6 Zone Tamper Restores Disabled ON I___I 7 System Maintenance Events Disabled ON I___I 8 Generic Zone Reporting Detailed Zone Reporting 21 Sys...

Страница 23: ...19 Programming Worksheets 24 Number of Attempts Default Range 03 I___I___I 01 FF Hex 25 Response Wait Time Default Range FA I___I___I 01 FF Hex seconds For UL Installations program 5A...

Страница 24: ...Indication This value is transmitted to Connect 24 during the periodic test transmission and can be viewed after power up by pressing the enroll button SID System Identification Number ID Number of th...

Страница 25: ...ne ZHXX R140 Sprinkler Zone SAXX E110 Sprinkler Zone SHXX R110 Hold up Zone HAXX E122 Hold up Zone HHXX R122 Trouble Zone YX00 E300 Trouble Zone YZ00 R300 Zone Fault Alarms Zone Fault Restores Burglar...

Страница 26: ...TXX E373 Sprinkler Zone SJXX R373 Hold up Zone HTXX E380 Hold up Zone HJXX R380 Trouble Zone UTXX E380 Trouble Zone UJXX R380 Generic Zone Events System Events Generic Burglary BA98 E130 98 Input Supp...

Страница 27: ...EMENT This Class B digital apparatus meets all requirements of the Canadian interference causing equipment regulations Cet appareil num rique de la Classe B respecte toutes les exigences de r glement...

Страница 28: ...ital Security Controls Ltd Toronto Canada www dsc com Tech Support 1 800 387 3630 Canada US or 905 760 3036 Printed in Canada 29034673 Rev 001 Direct all comments concerning this publication to pubs d...

Отзывы: