Model
3G2080(R)E
Cellular only
TL280(R)E
Internet only
TL2803G(R)E
Internet and Cellular
Power is supplied from the panel’s PC-Link header or a PCL-422 module in remote cabinet
installations. In remote cabinet installations, the PCL-422 module located with the communicator is
powered by either an HSM2204 or an HSM2300. Refer to the PCL-422 installation instructions for
details.
Current Consumption
Standby Current
90mA @ 13.66V
120mA @ 13.66V
Alarm (Transmitting)
Current
400mA @ 12V
Operating Frequency
900MHz, 1800MHz, 2100MHz
Typical Antenna Gain
2dBi
Environmental Specifications
Operating Temperature
-10°C to 55°C
Humidity
5% ~ 93% relative humidity, non-condensing
Mechanical Specifications
Board Dimensions (mm)
100 × 150 × 15
100 × 150 × 15
Weight (grams) with
bracket
310
320
Table 2: Compatible Receivers and Panels
Communicator Receiver/Panel
Description
3G2080(R)E
Receiver
l
Sur-Gard System I-IP Receiver, version 1.13+
l
Sur-Gard System II Receiver, version 2.10+
l
Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
l
Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
l
Sur-Gard SG-DRL5-IP version 1.00+ (for Sur-Gard System 5 Receiver)
TL2803G(R)E Panel
l
HS2016
l
HS2016-4
l
HS2032
l
HS2064
l
HS2128
NOTE:
Enter [*][8][Installer Code][900] at keypad to view the panel version number.
Pre Installation Configuration
Encryption
The communicator uses 128 Bit AES encryption. Encryption can only be enabled from the monitoring station receiver. Each
receiver (Ethernet 1 and 2, cellular 1 and 2) can independently have encryption enabled or disabled. When encryption is
enabled, the central station will configure the device to encrypt communications the next time the communicator module per-
forms a communication to that receiver.
NOTE:
Packets will start being encrypted only after the next event is sent to that receiver, or if the unit is restarted.
Before leaving the installation site, the communicator TL2803G(R)E Ethernet line shall be connected via an APPROVED
(acceptable to the local authorities) Network Interface Device (NID). All wiring shall be performed according to the local
electrical codes.
Communicator Installation Configuration
This HSPA(3G)/dual- path alarm communicator shall be installed by service persons only (service person is defined as a per-
son having the appropriate technical training and experience necessary to be aware of hazards to which that person may be
exposed to in performing a task and can also take measures to minimize the risks to that person or other persons). The Com-
municator shall be installed and used within an environment that provides the pollution degree max 2, overvoltages category II,
in non-hazardous, indoor locations only. This manual shall be used with the installation manual of the panel which is con-
nected to the communicator. All instructions specified within the panel manual must be observed.
All the local rules imposed by local electrical codes shall be observed and respected during installation.
5