[074] Key Options
[076] First Keypad Options
[077] Second Keypad Options
[080] PGM Terminal 1
Default: 01
I_______I _______I
1-14 Follow PGM Output Number, 15 Local PGM Pulse, 16 Local PGM Toggle
[082] Local PGM Output Pulse Activation Time
Default: 00
I_______I _______I
Minutes (Valid Range 00-99)
Default: 05
I_______I _______I
Seconds (Valid Range 00-99)
[101]-[108] Partition Labels
(PK5500\RFK5500 Only)
ex. For Partition 1 enter section [101], for Partition 2 enter section [102] etc.
NOTE: Partition 1 Label is also used as the System Label
[120]-[151] Command Output Labels
(PK5500\RFK5500 Only)
Default: “Command_O/P_1” - “Command_O/P_4”
[201]-[264] Door Chime Sound Programming
You can program the keypad to make up to four different door chime sounds for individual zones.
ex. For Zone 1 enter section [201], for Zone 2 enter section [202] etc.
[994][
] Initiate Global Keypad Chime Broadcast
[995][
] Reset Keypad Options to Factory Default
[996][
] Label Default (PK5500\RFK5500 Only)
[997] View Software Version (PK5500\RFK5500 Only)
[998][
] Initiate Global Label Broadcast (PK5500\RFK5500 Only)
[999][
] Reset Keypad EEPROM to Factory Defaults
Default
Option
ON
OFF
ON
I____I
1 [F]ire Key Enabled
[F]ire Key Disabled
ON
I____I
2 [A]uxiliary Key Enabled
[A]uxiliary Key Disabled
ON
I____I
3 [P]anic Key Enabled
[P]anic Key Disabled
OFF
I____I
4-8 For Future Use
Default
Option
ON
OFF
ON
I____I
1 Display Code when Programming
Display “Xs” when Programming
ON
I____I
2 Local Clock Display ON
Local Clock Display OFF
OFF
I____I
3 Local Clock Displays 24-hr Time
Local Clock Displays AM/PM
ON
I____I
4 Auto Alarm Memory Scroll Enabled
Auto Alarm Memory Scroll Disabled
OFF
I____I
5 Local Display of Temperature ON
Local Display of Temperature OFF
ON
I____I
6 Bypass Options prompt ON
Bypass Options prompt OFF
OFF
I____I
7 For Future Use
OFF
I____I
8 Auto-Scroll Open Zones ON
Auto-Scroll Open Zones OFF
Default
Option
ON
OFF
ON
I____I
1 Chime Enabled for Zone Openings
Chime Disabled for Zone Openings
ON
I____I
2 Chime Enabled for Zone Closings
Chime Disabled for Zone Closings
OFF
I____I
3 5th Terminal is Keypad PGM Output
5th Terminal is Keypad Zone Input
ON
I____I
4 Language Selection Enabled
Language Selection Disabled
OFF
I____I
5 Power LED Enabled
Power LED Disabled
ON
I____I
6 Power LED indicates AC present
Power LED indicates AC absent
ON
I____I
7 Alarms always Displayed When Armed Alarms not Displayed When Armed
OFF
I____I
8 Low Temperature Warning Enabled
Low Temperature Warning Disabled
Section
Partition
Label
[101]- [108] 1 to 8
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
For Partition 1 Command O/P 1 to 4 enter [120] to [123]
For Partition 5 Command O/P 1 to 4 enter [136] to [139]
For Partition 2 Command O/P 1 to 4 enter [124] to [127]
For Partition 6 Command O/P 1 to 4 enter [140] to [143]
For Partition 3 Command O/P 1 to 4 enter [128] to [131]
For Partition 7 Command O/P 1 to 4 enter [144] to [147]
For Partition 4 Command O/P 1 to 4 enter [132] to [135]
For Partition 8 Command O/P 1 to 4 enter [148] to [151]
Section Part Cmd.
Output
Label
[120]-[151]1to8 1to4
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
Default
Option
ON
OFF
ON
I____I
1
6 Beeps
Disabled
OFF
I____I
2
“Bing-Bing” Sound
Disabled
OFF
I____I
3
“Ding-Dong” Sound
Disabled
OFF
I____I
4
Alarm Tone
Disabled
OFF
I____I
5-8
For Future Use