Features

The PGx974(P) (pet-immune) are 2-way, microprocessor-con-
trolled, wireless digital mirror PIR detectors which include the
following features:

• Built-in link quality indicators reduce installation time by 

eliminating the need for the installer to physically approach 
the control panel.

• Adaptive Active Infra-Red Anti-Masking technology 

providing the most advanced reliable protection against 
intentional masking attempts (patent pending).

• Includes a fully supervised PowerG transceiver.
• Incorporates patent pending black mirrors for extremely 

high white light immunity.

• Advanced elliptical / parabolic mirror technology 

(patented).

• V-slot® optic technology (patented) for improved 

robustness, anti-vandalism and for very high reliability.

• Creep zone protection.
• PGx974P can distinguish between human beings and pets 

weighing up to 18 kg (40 lb).

• The advanced True Motion Recognition™ algorithm 

(patented) distinguishes between the true motion of an 
intruder and any other disturbances which may cause false 
alarms.

• No vertical adjustment is needed.
• Motion event counter determines whether 1 or 2 

consecutive motion events will trigger an alarm.

• Automatic termination of walk-test after 15 minutes.
• Microprocessor-controlled temperature compensation.
• Sealed chamber protects the optical system.
• Front and back tamper protection.
• Self-test.

Device Setup

Note: 

To ensure the continued operation of all wireless devices

after performing a system default, a global upload of all wire-
less programming via DLS is recommended before defaulting
the system. After completing the system default, download the
wireless programming. 

Legend

A. Screw cover
B. LED 
C. PIR optical window
D. Enroll button (use a screwdriver to press the recessed but-

ton)

E. Battery
F.

Tamper switch

G. Break-away base segment (shaded)
H. Mounting height
I.

Coverage range

J.

Horizontal view

K. Vertical view
X. Lower surface (with downward tilt)
Y. Upper surface (without downward tilt)

Installing the Battery

Caution!

 Risk of explosion if battery is replaced by an incor-

rect type. Dispose of used batteries according to the manufac-
turer's instructions and according to local rules and regulations.
Batteries are to be replaced by service persons only.
1. On the indicated location, lift the screw cover upward using

your thumb.

2. Release the screw and open the cover in the direction shown 

by the arrow.

3. Insert a screwdriver into the slot and then push inward to sep-

arate the base from the cover.

4. Insert battery while observing polarity.

Note: 

When manually programming wireless devices, if a

device has been powered up for more than 48 hours it cannot be
enrolled into the system until the device has been tampered and
restored. When programming the panel using the Quick Enroll
procedure follow the steps detailed in Enroll the Device into the
System.

Note: 

After restoring a low battery trouble the system may take

up to 5 minutes to clear the trouble.

Enroll the Device into the System

To quick enroll:
1. On a keypad press [*] [8] [Installer Code] [804] [000].
2. Press and hold the device enroll button until the LED lights 

steady and then release the enroll button while the LED is 
still lit. A confirmation message then appears on the keypad.

3. Press [*] key to confirm ID.
4. Enter [3 digit zone #].
5. Enter [3 digit zone type].
6. Enter [1 digit partition #] for all desired partitions and press 

[#]. If using an LCD keypad you can scroll to the desired par-
titions and press [*] to toggle the partition.

7. On an LCD keypad enter the label by using word library.
To pre-enroll:
1. Remotely configure the unique ID number into the system.

For more information see the HSM2HOST manual.

2. When on-site, press the device enroll button.

Note: 

If the wireless device has been powered for more than 48

hours without being enrolled, tamper and restore the device to
enroll it.

Perform a Placement Test

Before permanently mounting any wireless device, temporarily
mount the device and perform a Placement test.
1. Tamper the device by removing the cover.
2. Restore the tamper. The device now enters Placement test 

mode for 15 minutes.

3. Trip the device and the red LED blinks once to identify that a 

signal is being sent to the receiver and then blinks three times 
to identify the signal strength. To perform a walk test, walk 
across the far end of coverage pattern in both directions. The 
following table indicates the received signal strength indica-
tion. 

IMPORTANT! 

Only GOOD or STRONG signal strengths are

acceptable. If you receive a POOR signal from the device, re-

locate it and re-test until a GOOD or STRONG signal is
received. 

Note:

 For UL/ULC installations, only STRONG signal levels

are acceptable. After installation verify the product functional-
ity in conjunction with the compatible receivers HSM2HOST9,
HS2LCDRF(P)9, HS2ICNRF(P)9 and PG9920.

Note:

 For detailed Placement instructions refer to the control

panel Reference Guide.

Note:

 Perform a walk test of the coverage area at least once a

year to ensure that the detector is working correctly.

Mounting

Note:

 Mount the detector so that its orientation is perpendicular

to the expected intrusion path. For the desired detector's range
and height, use mounting holes 

x

 or 

y

, as specified in the table

below.

Note:

 To be installed by service persons in non-hazardous loca-

tions only.
Use the following as a guide for locating a suitable mounting
location:

• Keep away from heat sources.
• Do not expose to air drafts.
• Do not install outdoors.
• Avoid direct sunshine.
• Keep wiring away from power cables.
• Do not install behind partitions.
• Mount on solid stable surface.

Caution!

 The back tamper switch will not protect the unit

unless the break-away base segment is secured to the wall with
at least one screw.

Configuration

To enter the wireless configuration section enter [804][000].

Device Toggles

Selections

Event Indications

Specifications

GENERAL

Detector Type: 

Dual element low-noise pyroelectric sensor

Lens Data

Max. Coverage: 

15 m (49 ft) / 90°25 m (82 ft) x 2.5 m

Pet Immunity (only): 

Up to 38 kg (85 lb)

ELECTRICAL

Internal Battery: 

3V Lithium battery, type CR-123A (option-

ally can be used type CR-17450)

Note:

 For UL installations use Gold Peak (GP) only. Use only 

the above battery type.

Nominal Battery Capacity: 

1450 mA/h ( 2400mA/h for 

optional CR17450) 

Low Battery Threshold: 

2.45 V

Battery Life (for typical use): 

7 years (not tested by UL/ULC)

FUNCTIONAL

True Motion Event Verification: 

2 remote selections - 1 

(OFF) or 2 (ON) motion events

Alarm Period: 

2 seconds

WIRELESS

Frequency Band (MHz): 

CE Listed PG4974: 433MHz; CE/

EN listed PG8974: 868MHz; FCC/IC/UL/ULC listed PG9974: 
912-919MHz

Communication Protocol: 

PowerG

Supervision: 

Signaling at 4-min. intervals

Tamper Alert: 

Reported when a tamper event occurs and in 

any subsequent message, until the tamper switch is restored

MOUNTING

Height: 

1.8 – 3.0 m (6 - 10 ft).

Installation Options:

 Surface or corner

ACCESSORIES

PGBRACKET-1: Surface mounted swivel bracket, adjustable 
30° down and 45° left/45° right.
PGBRACKET-2: PGBRACKET-1 with a corner adapter
PGBRACKET-3: PGBRACKET-1 with a ceiling adapter

Note:

 UL did not evaluate the product with the use of brackets.

ENVIRONMENTAL

RFI Protection: 

>20 V/m up to 2000 MHz, excluding inband 

frequencies

Temperature range:

 -10°C to +55°C (UL/ULC only verified 

the range 0ºC-49ºC

)

Relative Humidity: 

up to max. 93%RH, non-condensing

PHYSICAL

Size (H x W x D): 

115 x 60 x 48 mm (4-1/2 x 2-5/16 x 1-15/

16”)

Weight (with battery): 

90 g (3 oz).

Color: 

White

COMPATIBLE RECEIVERS

433MHz Band: HSM2HOST4; HS2LCDRF(P)4;HS2IC-
NRF(P)4; PG4920
868MHz Band: HSM2HOST8; HS2LCDRF(P)8; HS2IC-
NRF(P)8;PG8920
912-919MHz Band: HSM2HOST9; HS2LCDRF(P)9; HS2IC-
NRF(P)9; PG9920

Note: Only devices operating in band 912-919MHz are UL/
ULC listed.

UL/ULC Notes

Only model PG9974 operating in the frequency band 912-
919MHz is UL/ULC listed. The PG9974 has been listed by UL 
for commercial and residential burglary applications and by 
ULC for residential burglary applications in accordance with 
the requirements in the Standards UL 639 and ULC-S306 for 
Intrusion Detection Units.
For UL/ULC installations use these devices only in conjunction
with compatible DSC wireless receivers: HSM2HOST9,
HS2LCDRF(P)9, HS2ICNRF(P)9 and PG9920. After installa-
tion verify the product functionality in conjunction with the
compatible receiver used.

Europe: The PG8974 and PG4974 are compliant with the RTTE
requirements - Directive 1999/5/EC of the European Parliament
and of the Council of 9 March 1999. Model PG8974 certified by
DNV (DET NORSKE VERITAS) to the following standards:

EN50131-2-2, EN50131-1 GRADE 2, CLASS II, EN50131-6 Type C. DNV (DET
NORSKE VERITAS)  has certified only the 868 MHz variant of this product.
According to EN 50131-1:2006 and A1:2009, this equipment can be applied in
installed systems up to and including Security Grade 2, Environmental Class II.
UK: The PG8974 is suitable for use in systems installed to conform to
PD6662:2010 at Grade 2 and environmental class 2. BS8243 The Power G
peripheral devices have two- way communication functionality, providing
additional benefits as described in the technical brochure. This functionality has
not been tested to comply with the respective technical requirements and should
therefore be considered outside the scope of the product’s certification

FCC COMPLIANCE STATEMENT

WARNING! Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate the
equipment.
This device has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in residential
installations. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio and television reception.
However, there is no guarantee that interference will not occur in a particular
installation. If this device does cause such interference, which can be verified by
turning the device off and on, the user is encouraged to eliminate the interference
by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one that supplies
power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
This equipment complies with FCC and IC RF radiation exposure limits set forth
for an uncontrolled environment.
This device complies with FCC Rules Part 15 and with Industry Canada licence-
exempt RSS standard(s). Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept
any interference that may be received or that may cause undesired operation.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisee aux deux
conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2)
l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si
le brouillage est susceptible d'en compromettre le fonctionnement.

A

B

C

D

E

F

LED Response

Signal Strength 

Green LED blinks

STRONG 

Orange LED blinks

GOOD 

Red LED blinks

POOR 

No blinks

No communication

1

2

3

4

[001][01]

Alarm LED - Default [Y]

Enables the devices LED to activate when an alarm
event occurs.

[001][04]

Supervision - Default [Y]

Enables supervision of the device.

[003]

Hightraffic Shutdown - Default [01]

Activating this feature helps conserve battery power 

when the system is disarmed by configuring a reporting 

timer. When motion is detected, the device transmits an 

alarm to the receiver and will not report any further 

events until the timer expires. Any motion detected 

during the configured period will be reported once the 

timer expires. No Delay causes the device to report an 

alarm each time the detector is tripped.
[01] Detector Dis-

abled (while dis-

armed)

[02] No Delay

[03] 5 second 
delay

[04] 15 second 
delay

[05] 30 second 
delay

[06] 1m delay

[07] 5m delay

[08] 10m delay

[09] 20m delay

[10] 60m delay

[016]

Event counter - Default [002]

Alarm activates after a configured number of events 
have been detected.
Key in activities 
001-255

LED Indications

Event 

Red LED blinks

Stabilization (warm-up 120 
sec)

Red LED ON 0.2 sec.

Tamper open / close 

Red on 2 sec.

Intruder alarm

Yellow LED on 

AM detection – Diagnostic 
mode

Yellow LED blinks slowly
(0.2 sec. ON, 30 sec. OFF)

AM detection – Normal 
mode

6    1.8

7    2.1

8    2.4

9    2.7

10    3.0

ft     m

X
Y

X

X

Y
Y

X

X

Y
Y

Y

X

b

X

X

X

15

6

30

9

45
12

60 ft
15 m

G

G

I

H

x

Y

x

Y

Yellow and red LED blink 
simultaneously (0.2 sec. ON 
[both], 0.2 sec. OFF)

Self-test failure – Diagnostic 
mode

Yellow and red LED blink 
simultaneously slowly (0.2 
sec. ON [both], 30 sec. OFF)

Self-test failure – Normal 
mode

No. of Beam Elements:

18x3=54 far parabolic mirror seg-

ments

LED Indications

Event 

5

0

16.4

0

15 m

49.2 ft

10

32.8

5m

16.4ft

5m

16.4ft

10m

32.8ft

10m

32.8ft

J

2.1 m

(6.9 ft)

5

10

15  m

16.4

32.8

49.2 ft

K

D-304674

Содержание PG9974(P)

Страница 1: ... OFF or 2 ON motion events Alarm Period 2 seconds WIRELESS Frequency Band MHz CE Listed PG4974 433MHz CE EN listed PG8974 868MHz FCC IC UL ULC listed PG9974 912 919MHz Communication Protocol PowerG Supervision Signaling at 4 min intervals Tamper Alert Reported when a tamper event occurs and in any subsequent message until the tamper switch is restored MOUNTING Height 1 8 3 0 m 6 10 ft Installation...

Страница 2: ...ion sur la lentille Couverture max 15 m 49 pieds 90 25 m 82 pieds x 2 5 m Insensibilité aux animaux uniquement 38 kg 85 lb max DONNÉES ÉLECTRIQUES Batterie interne Batterie au lithium de 3 V de type CR 123A utiliser éventuellement le type CR 17450 Remarque Pour les installations UL utilisez exclusivement des piles Gold Peak GP Utilisez exclusivement le type de pile indiqué ci dessus Capacité nomin...

Страница 3: ...Supervisión Señalización a intervalos de 4 minutos Alerta contra manipulaciones Informado cuando ocurre un evento de manipulación y en cualquier mensaje posterior hasta que se restablezca el interruptor contra manipulación MONTAJE Altura 1 8 3 0 m 6 10 pies Opciones de instalación Superficie o esquina ACCESORIOS PGBRACKET 1 Soporte giratorio montado en superficie ajustable 30 hacia abajo y 45 a la...

Страница 4: ...patíveis com DSC HSM2HOST9 HS2LCDRF P 9 HS2ICNRF P 9 e PG9920 Depois da instalação verifique a funcionalidade do produto em conjunto com o receptor compatível usado Europa O modelo PG8974 e PG4974 está conforme os requisitos RTTE Diretiva 1995 5 EC do Parlamento Europeu e do Conselho de 9 de março 1999 PG8974 ecrtificado pela DNV DET NORSKE VERITAS para as seguintes normas EN50131 2 2 EN50131 1 GR...

Страница 5: ...SC refuse de Vous octroyer une licence d utilisation du PRODUIT LOGICIEL et Vous n avez pas le droit de l utiliser LICENCES DU PRODUIT LOCIGIEL Le PRODUIT LOGICIEL est protégé par des lois sur le droit d auteur et des traités internationaux sur le droit d auteur ainsi que par d autres lois et traités de la propriété intellectuelle Le droit d utilisation du PRODUIT LOGICIEL est octroyé pas vendu 1 ...

Страница 6: ...adas partições de vidro portas ou janelas de vidro Qualquer tipo de violação seja intencional ou não intencional tais como mascaramento pintura ou borrifação de qualquer material nos sensores espelhos janelas ou qualquer outra parte do sistema de detecção prejudicará sua operação adequada Os detectores de movimento com infravermelho passivo operam detectando alterações na temperatura Entretanto a ...

Отзывы: