
[702] Second International Options Code
'HIDXOW
2SWLRQ
21
2II
6HFWLRQ3DJH
OFF
I_______I
1
Pulse Dialing Make/Break Ratio is 33/67 Pulse Dialing Make/Break Ratio is 40/60
5.5
15
ON
I_______I
2
Force Dialing enabled
Force Dialing disabled
5.5
15
OFF
I_______I
3
Land line Test Transmission in minutes
Land line Test Transmission in days
5.14
22
OFF
I_______I
4
1600 Hz Handshake
Standard Handshake
5.9
17
OFF
I_______I
5
ID Tone enabled
ID Tone disabled
5.5
15
OFF
I_______I
6
2100 HZ ID Tone
1300 Hz ID Tone
5.5
15
OFF
I_______I
7
One Time 1-Hr User enabled DLS Window Full 6-Hr User enabled DLS Window
5.10
19
OFF
I_______I
8
Bell on FTC when armed
FTC Trouble only when armed
5.5
15
[703] Delay Between Dialing Attempts
(Section 5.5 “Communicator – Dialing” on page 15)
'HIDXOW
001
I_________I________I________I
(Valid entries are 000-255 Seconds)
Module Programming
[801] PC5400 Printer Module Programming
Please refer to your PC5400 Installation Manual for installation and programming instructions.
[803]LINKS2X50 Long Range Radio Interface Programming
Please refer to your LINKS2150 Installation Manual for installation and programming instructions.
[804] PC5132 Wireless Expansion Programming
Please refer to your PC5132 Installation Manual for programming locations and instructions.
Special Installer Functions
[901] Installer Walk Test Mode Enable / Disable
(Section 5.32 “Walk Test (Installer)” on page 25)
[902] Module Supervision Reset
(Section 2.7 “Removing Modules” on page 5)
[903] Module Supervision Field
(Section 2.6 “Supervision” on page 5)
[904] Wireless Module Placement Test
For more information, please refer to your PC5132 Installation Manual
•
Select the module / transmitter (Zones 01-8).
•
Press [#] to Cancel.
3ODFHPHQW
/HG.H\SDG
/&'.H\SDG
%HOO%X]]HU
Good
Light 1 ON Steady
“GOOD”
1 Beep / Squawk
Fair
Light 2 ON Steady
“FAIR”
2 Beeps / Squawks
Bad
Light 3 ON Steady
“BAD”
3 Beeps / Squawks
[990] Installer Lockout Enable
(Section 5.31 “Installer’s Lockout” on page 25)
[991] Installer Lockout Disable
(Section 5.31 “Installer’s Lockout” on page 25)
[993]Restore LINKS2X50 Factory Default Programming
(Section 5.30 “Resetting Factory Defaults” on page 24)
[996] Restore PC5132 Factory Default Programming
(Section 5.30 “Resetting Factory Defaults” on page 24)
[997] Restore PC5400 Factory Default Programming
(Section 5.30 “Resetting Factory Defaults” on page 24)
[999] Restore PC1565 Factory Default Programming
(Section 5.30 “Resetting Factory Defaults” on page 24)
Содержание PDigital Security PC1565
Страница 4: ...ii PC1565 Wiring Diagram...
Страница 55: ...Notes...