Section 1: System Introduction
1.1
Specifications
Downloading Software Support
•
PC585 v2.3 uses DLS-1 v6.7 and up.
Flexible Zone Configuration
•
Four fully programmable zones
•
System expandable to 32 zones using:
•
up to 8 keypad zone inputs and/or
•
up to 32 wireless zones with the PC5132 wireless
expansion module
•
38 access codes: one master code, one maintenance
code, two duress codes, two supervision codes and 32
general access codes
•
27 zone types; 8 programmable zone attributes
•
Normally closed, single EOL and double EOL zone wiring
Audible Alarm Output
•
700mA Supervised Bell Output (current limited at 3 amps),
12V
DC
•
Steady or Pulsed Output
EEPROM Memory
•
Does not lose programming or system status on complete
AC and Battery failure
Programmable Outputs
•
Two programmable outputs; 18 programmable options
•
PGM1 = 300mA; PGM2 = 50mA
Powerful 1.5 Amp Regulated Power Supply
•
550 mA Auxiliary Supply, 12 V
DC
•
Positive Temperature Coefficient (PTC) components
replace fuses
•
Supervision for loss of AC power, low battery
•
Internal clock locked to AC power frequency
Power Requirements
•
Transformer = 16.5 V
AC
, 40VA
•
Battery = 12 volt 4 Ah minimum rechargeable sealed lead
acid battery
Remote Keypad Specifications
•
Keypads available:
- PC5509 eight zone LED keypad
- PC1555RKZ eight zone LED keypad with zone input
- PC5508Z eight zone LED keypad with zone input
- PC5516Z sixteen zone LED keypad with zone input
- PC5532Z thirty-two zone LED keypad with zone input
- LCD5500Z Alphanumeric keypad with zone input
•
All keypads (except PC5509) have five programmable
function keys
•
Connect up to eight keypads
•
4-wire (Quad) connection to Keybus
•
Built in piezoelectric buzzer
Digital Communicator Specifications
•
Supports major communication formats including SIA and
Contact ID
•
Event-initiated personal paging
•
Three programmable telephone numbers
•
Two account numbers
•
Supports LINKS1000 cellular communication
•
Supports LINKS2X50 long range radio transmitter
•
DTMF and pulse dialing
•
DPDT line seizure
•
Anti-jam feature
•
Split reporting of selected transmissions to each telephone
number
System Supervision Features
The PC585 continuously monitors a number of possible trou-
ble conditions including:
•
AC power failure
• AUX Power Supply Trouble
•
Fault by zone
• Loss of internal clock
•
Tamper by zone
• Bell output trouble
•
Fire trouble
• Telephone line trouble
•
Failure to communicate
• Low battery condition (panel)
•
Low battery by zone (wireless)
•
Module fault (supervisory or tamper)
False Alarm Prevention Features
•
Audible Exit Delay
• Quick Exit
•
Audible Exit Fault
• Cross Zone Burglary Alarm
•
Communication Delay
• Rotating Keypress Buffer
•
Urgency on Entry Delay
• One Restart of Exit Delay
Additional Features
•
Auto Arm at specified time
•
Keypad-activated alarm output and communicator test
•
All modules connect to the system via a four wire Keybus
up to 1000’/305m from main panel
•
An event buffer which records the past 128 events with
both the time and date at which they occurred; buffer can
be printed using PC5400 serial interface module, or
viewed with the LCD5500Z keypad and DLS-1 software
•
Supports the addition of the PC5132 wireless receiver for
integration of wireless devices
•
Uploading and downloading capability
•
Local downloading capability through the use of the
PC-LINK adaptor
•
Added Keybus fault protection: clock and data outputs
have been programmed to withstand shorts to +12v to pre-
vent control panel damage