40
[370] Communication Variables
Default
Section
Page #
003
I_______I_______I_______I
Swinger Shutdown (Alarms and Rest) (001-014 Transmissions, 000=disabled)
5.19
25
003
I_______I_______I_______I
Swinger Shutdown (Tampers and Rest)(001-014 Transmissions, 000=disabled)
5.19
25
003
I_______I_______I_______I
Swinger Shutdown (Maint and Rest)
(001-014 Transmissions, 000=disabled)
5.19
25
000
I_______I_______I_______I
Transmission Delay
(001-255 seconds)
5.15
23
030
I_______I_______I_______I
AC Failure Communication Delay
(001-255 minutes)
5.8
18
003
I_______I_______I_______I
TLM Trouble Delay
(No. of checks required - valid entries 003 - 255) 5.12
23
030
I_______I_______I_______I
Test Transmission Cycle (land line)
(001-255 minutes/days)†
5.14
23
030
I_______I_______I_______I
Test Transmission Cycle (LINKS)
(001-255 days)
5.14
23
007
I_______I_______I_______I
Zone Low Battery Transmission Delay (000-255 days)
5.8
18
030
I_______I_______I_______I
Delinquency Transmission Cycle
(000-255 days/hours)
5.8
18
†Depends on programming in section [702], option [3].
NOTE: To disable the AC failure communications delay, program [000].
[371] Test Transmission Time of Day
(Section 5.14 “Test Transmission” on page 23)
NOTE: If the land line test transmission cycle is programmed in minutes (section [702], option [3]), this section will not affect the land
line test transmission cycle.
Default
9999
I_______I_______I_______I_______I
(Valid entries are 0000-2359, 9999 to disable)
[380] First Communicator Option Code
Default Option
ON
OFF
Section
Page
#
ON
I_______I
1
Communications
Enabled
Communications
Disabled
5.5
17
OFF
I_______I
2
Restorals on Bell Time-out
Restorals Follow Zones
5.8
18
OFF
I_______I
3
Pulse
Dialing
DTMF
Dialing
5.5
17
ON
I_______I
4
Switch to Pulse Dialing on 5th Attempt
DTMF Dial For All Attempts
5.5
17
OFF
I_______I
5
3rd Telephone Number enabled
3rd Telephone Number disabled
5.7
17
OFF
I_______I
6
Alternate Dial (1st and 3rd)
Call 1st Number, Backup to 3rd
5.7
17
OFF
I_______I
7
Call LINKS as well as Land Line
LINKS is Backup of Land Line(s)
5.26
26
OFF
I_______I
8
Delinquency Follows Zone Activity (Hours)
Delinquency Follows Arming (Days)
5.8
18
[381] Second Communicator Option Code
Default Option
ON
OFF
Section
Page
#
OFF
I_______I
1
Open After Alarm Kypd Ringback enabled
Open After Alrm Kypd Ringback disabled
5.17
24
OFF
I_______I
2
Open After Alarm Bell Ringback enabled
Open After Alrm Bell Ringback disabled
5.17
24
OFF
I_______I
3
SIA Sends Programmed Rep. Codes
SIA Sends Automatic Rep. Codes
5.9
19
OFF
I_______I
4
Closing Confirmation Enabled
Closing Confirmation Disabled
5.17
24
OFF
I_______I
5-6
For future use
—
ON
I_______I
7
Contact ID Uses Programmed Rep. Codes
Contact ID Uses Automatic Rep. Codes
5.9
19
OFF
I_______I
8
For future use
—
[390] LINKS Preamble (First Telephone Number)
(Section 5.26 “LINKS1000 Cellular Communicator” on page 26)
Default:
FFFF
I_______I_______I_______I_______I
(Program all unused digits with Hex F)
[391] LINKS Preamble (Second Telephone Number)
(Section 5.26 “LINKS1000 Cellular Communicator” on page 26)
Default:
FFFF
I_______I_______I_______I_______I
(Program all unused digits with Hex F)
[392] LINKS Preamble (Third Telephone Number)
(Section 5.26 “LINKS1000 Cellular Communicator” on page 26)
Default:
FFFF
I_______I_______I_______I_______I
(Program all unused digits with Hex F)
[393] LINKS Special Function Preamble (All Telephone Numbers)
(Section 5.26 “LINKS1000 Cellular Communicator” on
page 26)
Default:
FFFFFF
I_______I_______I_______I_______I_______I_______I
(Program all unused digits with Hex F)
•Enter [*][2][*] (HEX B) to dial [*]
• Enter [*][3][*] (HEX C) to dial [#]
Содержание New Classic PC585
Страница 4: ...ii PC585 Wiring Diagram ...
Страница 51: ......