7
4. Enter the 2-digit number of the function you want to select, or scroll to the
function you want to assign to that button and press [
✱
]. The following
functions may be programmed:
00 Null Key
07
Arm Interior
01 Stay Arm
08-15 [
✱
][7] Command Outputs 1-8
02 Away Arm
16
Fire Alarm
03 No-Entry Arm
17
Auxiliary Alarm
04 Chime On/Off
18
Panic Alarm
05 System Test
19
Disarm (Off)
06 Quick Exit
NOTE: If programmed, these options do not require access code entry regardless of other
system options. The programmed function will be executed immediately.
5. The LCD keypad will show
Select (01) Partition 1
. Scroll to the partition you want
the button to work in and press [
✱
] to select.
6. Repeat steps 3 to 5 until all the buttons are programmed.
7. Repeat steps 4 to 6 until all the wireless keys are programmed.
8. To exit, press [#].
NOTE: When a wireless key is used to disarm a partition, all courtesy pulse outputs enabled
for that partition will activate for two minutes.
Now that you have enrolled and programmed all the wireless devices, you will need to
test the devices and mount wireless devices using zones. See section 4 for more
information.
I N S T A L L I N G W I R E L E S S D E V I C E S
firealarmresources.com