The minimum height of a chimney system

for the D.S. Furnace is 20 feet. The chimney

must exceed the roof of a house at a minimum

of 3 feet at any point of exit. In a pitched roof

installation the chimney must be 2 feet higher

than anything within a 10 foot radius of the

chimney. It is important to have a chimney draft

of 0.06 inches water column. It is required to

abide by the manufacturer’s instructions on

Class A  chimneys as well as local building

codes. It is not recommended to build a chim-

ney on an addition that is lower than the main

part of your house. 

Do Not extend the single

wall chimney connector past the inside of a

masonry chimney liner. Never connect this

unit to a chimney serving another appliance.

Should you have a problem with inadequate

draft you should see page 11.

Chimney Requirements

Locating Furnace

This furnace is to be installed maintaining

clearances as shown in illustration.

 1.  Set the furnace on a solid noncom

      bustible floor.

 2.  Use a U.L. approved fire retardant 

      material for the floor mat.

 3.  The material must extend at least 

      16” in front of and 8” on either side 

      and back, and underneath the  

      chimney connector and extending at 

      least 2” on either side of the     

      chimney  connector.

1. The furnace should be the only heating appliance using a chimney. One furnace per flue.

2. A masonry chimney should be a chimtek or stainless steel liner.

3. The masonry chimney should not have any missing mortar or loose bricks.

4. There should be no mortar or parts of the chimney blocking the chimney flue.

5. There should be a two inch clearance between any chimney except chimtek has zero clearance.

6. The chimney should extend at least 2’ above the highest point of the house, or 2’ above the point

at which the chimney is 10’ from the roof.

According to NFPA Standards single wall chim-

ney connector can be within 9” of combustible

provided an approved fire retardant material

covered with 28 gauge sheet metal, spaced out

1” on non-combustible spacers is utilized.

Manual for EnergyMAX 2017.qxp_Manual for EnergyMAX  7/3/17  9:14 AM  Page 5

Содержание EnergyMAX 110

Страница 1: ...st Read all instructions carefully Install smoke and carbon monoxide detectors This stove meets U S Test Standard UL 391 ETLM78 1 CAN CSA 366 1 MADE IN USA By D S MACHINE SHOP Model 110 Model 160 Do Not Discard This Manual Manual for EnergyMAX 2017 qxp_Manual for EnergyMAX 7 3 17 9 14 AM Page 1 ...

Страница 2: ...urning anything other than anthracite hard coal Safety Instructions 2 Operational Work Practice Standards 1 When starting a fire set hot air regulator on furnace to HIGH 2 Completely open bypass damper on front top center of furnace See page 6 for location 3 Open fire door and place wads of crushed paper in the firebox 4 Put kindling on top of paper NOTE You can also buy Fire Starter Gel or Bricks...

Страница 3: ...n it to BURN OFF this dirt and oil before installing unit 21 Equip your home with fire extinguishers carbon monoxide and smoke detectors 22 Do not burn garbage gasoline or any other flammable liquids in this furnace 23 Do not burn furnace over 600 degrees Fahrenheit or warranty will be void Energy Max Annual Maintenance After each heating season 1 Clean out firebox and ash pan area 2 Remove firebr...

Страница 4: ...replacements Slope the flue pipe back towards the heater 1 4 per foot of horizontal run That way if any condensation forms in the pipe it will be carried back into the heater The connector pipe should be installed so that the upper pipe section fits inside the lower section This way any condensation building up inside the pipe will stay inside the pipe as it flows down the inside surface Horizonta...

Страница 5: ...furnace on a solid noncom bustible floor 2 Use a U L approved fire retardant material for the floor mat 3 The material must extend at least 16 in front of and 8 on either side and back and underneath the chimney connector and extending at least 2 on either side of the chimney connector 1 The furnace should be the only heating appliance using a chimney One furnace per flue 2 A masonry chimney shoul...

Страница 6: ...umb screw is for manual draft control to prevent unit from completely shutting down on a low burn Do not burn hotter than 600 degrees Fahrenheit on furnace top speed controller Airwash Adjustment Airwash Adjustment Bypass Damper 6 Flue Bypass Damper Airwash Adjustment Bypass Damper 6 Flue 8 Flue Manual for EnergyMAX 2017 qxp_Manual for EnergyMAX 7 3 17 9 14 AM Page 6 ...

Страница 7: ... 3 h 110 ASH PAN 1 Ash Shaker Bar Assembly 110 110 ASBA 1 Steel Bypass Plate slide 110 110 SBV 2 Cast Iron Louvers 110 CI FL 1 Stainless Steel H Channel Firebrick Holder 110 110 HBR 1 Stainless Steel U Channel Firebrick Holder 110 110 TBR 1 Stainless Steel Firebrick Baffle Bracelet 110 110 FBH 1 2 piece cast iron downdraft baffle 110 CI 110 1 Top Door Gasket 3 4 Round x 4 110 3448 kit 1 Bottom Doo...

Страница 8: ... 2 x 9 Left Side BOTTOM 2 1 1 4 x 4 1 2 x 9 1 1 1 4 x 3 x 9 Right Side TOP 5 1 1 4 x 4 1 2 x 9 1 1 1 4 x 2 x 9 Right Side BOTTOM 5 1 1 4 x 4 1 2 x 9 1 1 1 4 x 2 x 9 Front 2 1 1 4 x 4 1 2 x 6 3 4 Back TOP 2 2 1 2 x 4 1 2 x 9 1 2 1 2 x 3 3 4 x 9 Back BOTTOM 2 2 1 2 x 4 1 2 x 9 1 2 1 2 x 3 3 4 x 9 Manual for EnergyMAX 2017 qxp_Manual for EnergyMAX 7 3 17 9 14 AM Page 8 ...

Страница 9: ... h 160 ASH PAN 1 Ash Shaker Bar Assembly 160 160 ASBA 1 Steel Bypass Plate slide 160 160 SBV 2 Cast Iron Louvers 116 CI FL 1 Stainless Steel H Channel Firebrick Holder 160 160 HBR 1 Stainless Steel U Channel Firebrick Holder 160 160 TBR 1 Stainless Steel Firebrick Baffle Bracelet 160 160 FBH 1 2 piece cast iron downdraft baffle 160 C1 160 1 Top Door Gasket 3 4 Round x 4 160 3448 kit 1 Bottom Door ...

Страница 10: ... 2 1 2 x 5 8 x 9 Front 3 1 1 4 x 4 1 2 x 6 3 4 1 1 1 4 x 3 3 4 x 6 3 4 Back TOP 2 2 1 2 x 4 1 2 x 9 1 2 1 2 x 4 x 9 1 2 1 2 x 2 1 4 x 9 Back BOTTOM 3 2 1 2 x 4 1 2 x 9 1 2 1 2 x 1 3 4 x 9 2 Primary Air Louvers Back 1 1 4 x 3 3 4 x 6 3 4 2 1 2 x 1 3 4 x 9 2 1 2 x 2 1 4 x 9 2 1 2 x 5 8 x 9 2 1 2 x 5 8 x 9 1 1 4 x 3 x 9 Louver Louver 2 1 2 x 4 x 9 Manual for EnergyMAX 2017 qxp_Manual for EnergyMAX 7 ...

Страница 11: ...ate Install hood on top of furnace to first floor If furnace room is warm but your home isn t put vents in floor to circulate heat Is furnace the recommended BTU size for your home If you have a Bimetal Regulator set at high and furnace does not heat properly shorten chain one or more notches Do not exceed 600 degrees on top of furnace Overheating will damage furnace 3 Problem Excess smoke or flam...

Страница 12: ...mplete the repair The owner may at his option and with D S Stoves approval have the furnace shipped to the factory for repair All labor and material costs for repair at the factory will be borne by D S Stoves The owner is responsible for all shipping costs D S Stoves door glass gaskets paint or enameled parts firebrick and furnace cement are not covered by this Limited Warranty With Optional Coil ...

Отзывы: