DS Stoves EnergyMAX 110 Скачать руководство пользователя страница 4

4

    1   - The furnace must be placed on a solid none combustible floor. If you have a combustible floor it

is required to use a code approved none combustible floor board (Type 1 Board)

    2   - It is recommended that the furnace be centrally located. 

         

Two Options for good circulation from basement to first floor:

          A

- Run a plenum from furnace to 1st floor – recommended 14” x 20” or larger with return vents

that equal at least 12% more in sq. inches.

         

B

- Install floor vents where needed without plenum. Extend the return vents at least 12” down

from the ceiling (see drawing).

    3   - Locate and read label on furnace before installation. The most important consideration in

installing your furnace is adequate clearance between the furnace and any combustible surface.

A furnace that is placed too close to a wall or to furniture can cause a fire.

    4   - The base must extend at least 16” beyond the front and back of the furnace, 8” to the sides of

fuel opening, and must extend under and 2” beyond either side of the single wall chimney con-

nector if it’s elbowed towards a wall (see page 4). 

    5   - The furnace must have its own flue. Do not connect this unit to a chimney flue serving other

appliances.

    6   - Connection of the furnace to the chimney should be made as directly as possible (6 feet maxi-

mum horizontal) and not more than two bends, when needed, should be used. No reduction in

flue pipe below 6 inches in diameter should be

used. The pipe connecting the furnace to the

chimney should be at least 24 gauge. Thicker

gauges are available and will resist corrosion

longer and need fewer replacements. Slope

the flue pipe back towards the heater, 1/4” per

foot of horizontal run. That way if any condensation forms in the pipe it will be carried back into

the heater. The connector pipe should be installed so that the upper pipe section fits inside the

lower section. This way any condensation building up inside the pipe will stay inside the pipe as

it flows down the inside surface. Horizontal pipe runs should have the pipe seams turned up.

Particular attention should be paid to the point where the flue passes through a wall or ceiling.

This penetration should always be made with a thimble, insulated pipe, and then proper acces-

sories following manufacturers instructions. Chimney connectors

must not pass through the ceiling, concealed spaces, or enter

the chimney in the attic, unless proper clearance or insulated

pipe is used following manufacturers instructions.

REMEMBER that all pipe sections should be con-

nected with at least 3 sheet metal screws per

joint. A fire in the stack may cause vibration

and poorly fastened piping may come

apart causing an extreme fire and

smoke hazard. Do not extend single

wall chimney connector past the

inside edge of the flue liner. If you

have a manufactured Stainless Steel

chimney, attach single wall chimney con-

nector to single wall chimney connector

adapter. Where the pipe connects to a

masonry chimney. The flu to the chimney

should be larger than the single wall chim-

ney connector so you can insert the pipe

out to the inside edge of the chimney, but

not past. Then seal as tight as possible

and cover with a trim collar.

Locating Furnace

CAUTION: 

Keep furnishings and other combustible

materials away from the stove.

Manual for EnergyMAX 2017.qxp_Manual for EnergyMAX  7/3/17  9:14 AM  Page 4

Содержание EnergyMAX 110

Страница 1: ...st Read all instructions carefully Install smoke and carbon monoxide detectors This stove meets U S Test Standard UL 391 ETLM78 1 CAN CSA 366 1 MADE IN USA By D S MACHINE SHOP Model 110 Model 160 Do Not Discard This Manual Manual for EnergyMAX 2017 qxp_Manual for EnergyMAX 7 3 17 9 14 AM Page 1 ...

Страница 2: ...urning anything other than anthracite hard coal Safety Instructions 2 Operational Work Practice Standards 1 When starting a fire set hot air regulator on furnace to HIGH 2 Completely open bypass damper on front top center of furnace See page 6 for location 3 Open fire door and place wads of crushed paper in the firebox 4 Put kindling on top of paper NOTE You can also buy Fire Starter Gel or Bricks...

Страница 3: ...n it to BURN OFF this dirt and oil before installing unit 21 Equip your home with fire extinguishers carbon monoxide and smoke detectors 22 Do not burn garbage gasoline or any other flammable liquids in this furnace 23 Do not burn furnace over 600 degrees Fahrenheit or warranty will be void Energy Max Annual Maintenance After each heating season 1 Clean out firebox and ash pan area 2 Remove firebr...

Страница 4: ...replacements Slope the flue pipe back towards the heater 1 4 per foot of horizontal run That way if any condensation forms in the pipe it will be carried back into the heater The connector pipe should be installed so that the upper pipe section fits inside the lower section This way any condensation building up inside the pipe will stay inside the pipe as it flows down the inside surface Horizonta...

Страница 5: ...furnace on a solid noncom bustible floor 2 Use a U L approved fire retardant material for the floor mat 3 The material must extend at least 16 in front of and 8 on either side and back and underneath the chimney connector and extending at least 2 on either side of the chimney connector 1 The furnace should be the only heating appliance using a chimney One furnace per flue 2 A masonry chimney shoul...

Страница 6: ...umb screw is for manual draft control to prevent unit from completely shutting down on a low burn Do not burn hotter than 600 degrees Fahrenheit on furnace top speed controller Airwash Adjustment Airwash Adjustment Bypass Damper 6 Flue Bypass Damper Airwash Adjustment Bypass Damper 6 Flue 8 Flue Manual for EnergyMAX 2017 qxp_Manual for EnergyMAX 7 3 17 9 14 AM Page 6 ...

Страница 7: ... 3 h 110 ASH PAN 1 Ash Shaker Bar Assembly 110 110 ASBA 1 Steel Bypass Plate slide 110 110 SBV 2 Cast Iron Louvers 110 CI FL 1 Stainless Steel H Channel Firebrick Holder 110 110 HBR 1 Stainless Steel U Channel Firebrick Holder 110 110 TBR 1 Stainless Steel Firebrick Baffle Bracelet 110 110 FBH 1 2 piece cast iron downdraft baffle 110 CI 110 1 Top Door Gasket 3 4 Round x 4 110 3448 kit 1 Bottom Doo...

Страница 8: ... 2 x 9 Left Side BOTTOM 2 1 1 4 x 4 1 2 x 9 1 1 1 4 x 3 x 9 Right Side TOP 5 1 1 4 x 4 1 2 x 9 1 1 1 4 x 2 x 9 Right Side BOTTOM 5 1 1 4 x 4 1 2 x 9 1 1 1 4 x 2 x 9 Front 2 1 1 4 x 4 1 2 x 6 3 4 Back TOP 2 2 1 2 x 4 1 2 x 9 1 2 1 2 x 3 3 4 x 9 Back BOTTOM 2 2 1 2 x 4 1 2 x 9 1 2 1 2 x 3 3 4 x 9 Manual for EnergyMAX 2017 qxp_Manual for EnergyMAX 7 3 17 9 14 AM Page 8 ...

Страница 9: ... h 160 ASH PAN 1 Ash Shaker Bar Assembly 160 160 ASBA 1 Steel Bypass Plate slide 160 160 SBV 2 Cast Iron Louvers 116 CI FL 1 Stainless Steel H Channel Firebrick Holder 160 160 HBR 1 Stainless Steel U Channel Firebrick Holder 160 160 TBR 1 Stainless Steel Firebrick Baffle Bracelet 160 160 FBH 1 2 piece cast iron downdraft baffle 160 C1 160 1 Top Door Gasket 3 4 Round x 4 160 3448 kit 1 Bottom Door ...

Страница 10: ... 2 1 2 x 5 8 x 9 Front 3 1 1 4 x 4 1 2 x 6 3 4 1 1 1 4 x 3 3 4 x 6 3 4 Back TOP 2 2 1 2 x 4 1 2 x 9 1 2 1 2 x 4 x 9 1 2 1 2 x 2 1 4 x 9 Back BOTTOM 3 2 1 2 x 4 1 2 x 9 1 2 1 2 x 1 3 4 x 9 2 Primary Air Louvers Back 1 1 4 x 3 3 4 x 6 3 4 2 1 2 x 1 3 4 x 9 2 1 2 x 2 1 4 x 9 2 1 2 x 5 8 x 9 2 1 2 x 5 8 x 9 1 1 4 x 3 x 9 Louver Louver 2 1 2 x 4 x 9 Manual for EnergyMAX 2017 qxp_Manual for EnergyMAX 7 ...

Страница 11: ...ate Install hood on top of furnace to first floor If furnace room is warm but your home isn t put vents in floor to circulate heat Is furnace the recommended BTU size for your home If you have a Bimetal Regulator set at high and furnace does not heat properly shorten chain one or more notches Do not exceed 600 degrees on top of furnace Overheating will damage furnace 3 Problem Excess smoke or flam...

Страница 12: ...mplete the repair The owner may at his option and with D S Stoves approval have the furnace shipped to the factory for repair All labor and material costs for repair at the factory will be borne by D S Stoves The owner is responsible for all shipping costs D S Stoves door glass gaskets paint or enameled parts firebrick and furnace cement are not covered by this Limited Warranty With Optional Coil ...

Отзывы: