                                Disconnect power at 
the service breaker before installing or 
servicing. NOT FOR HOUSEHOLD USE - 
MAY CAUSE BURNS.

                                

                                All units must be 
supplied with a 3-wire service. The 
ground wire must be connected to the 
dryer's backplate. 

                                Failure to properly 
ground unit could result in severe 
electrical shock and/or death.

2

Circuit Diagram

Circuit Board Module

Transistor 
Power Switch

MO2 HE2

N

MO1 HE1

L

Transistor 
Power Switch

VR

Thermostat 

Red(110-120V)/Brown (208-240~277V)

Black

Black

G/Y

B

lu

e

B

ro

w

n

M
o

to

W
it


T

h

e

r

m
a

S

w
it

c


2

A

Hea

ter 

W
ith T

her

mo-fuse

FOR SENSOR

SW.

FOR HEATER

 

White(110-120V)/Blue (208-240~277V)

Sensor module

ON

1

VR

FOR SPEED

G

G/Y

Y2 Filter

(

ONLY

 

208~240V)

(

ONL

Y

 

208~240V)

L

N

G

For 

T

emperature 

Control

Type Y attachment

If the power supply cord is damaged, it must be replaced by the manufacturer 
or its service agent or a qualified person in order to avoid a hazard. Disconnect 
the fixed wiring only in accordance with the wiring rules.  

This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.    

Children should be supervised to ensure that they do not play with the appliance.

                                This product is 
intended for installation by a qualified 
service person. Use2.08 mm² solid 

 

conductor for wiring.

(AWG NO.14)

General Safety Information

Содержание DF35DM

Страница 1: ...INTELLIGENT FACILITY SOLUTIONS Electric Works 3 Concourse Way Sheffield S1 2BJ United Kingdom Phone UK 44 0 114 354 0047 Phone Eire 353 190 36387 sales ihdryers co uk www intelligenthanddryers com ...

Страница 2: ...Model Deck Mounted DF35DM Dryflow Dri Tap Hand Dryer ...

Страница 3: ... 000 R P M Brush Type Dual Ball Bearings Auto Resetting Thermostat turns unit off at 95 C 203 F 100 500 W depending on room temperature Thermal cut off at 85 C 185 F Less than 15 seconds 0 3 0 4 W Infrared Automatic self adjusting 4 to 9 100 mm to 230 mm Adjustable standard 5 12 130 mm 20 mm 60 seconds auto shut off IP35 CLASS 1 5 6 kg 12 3 lbs 8 1 kg 17 9 lbs Stainless steel 304 Satin finished t ...

Страница 4: ...ED G G Y Y2 Filter ONLY 208 240V ONLY 208 240V L N G For Temperature Control Type Y attachment If the power supply cord is damaged it must be replaced by the manufacturer or its service agent or a qualified person in order to avoid a hazard Disconnect the fixed wiring only in accordance with the wiring rules This appliance is not intended for use by persons including children with reduced physical...

Страница 5: ...be at least 30 40mm Otherwise the mounting nut would not fit 35mm 1 37 3 Mounting steps of the spout A Insert the shaft of the spout through the hole on the basin B Thread in the rubber pad the stainless steel washer and the plastic mounting nut C Fasten with the hex tool A Center point Mounting hole Recommended Deck Thickness 10 30mm 0 39 1 18 4 Remove two screws from the cover A 30 40mm 1 18 1 5...

Страница 6: ...ube to the shaft of the spout g 5 Fix the stainless steel cabinet to the wall lead the power cord through the KO hole and connect it to the dryer POWER CORD 6 Connect the wires to the terminal as below Connections A Connect the live wire colored red or brown or white to the terminal block marked L B Connect the neutral wire colored black or blue to the terminal block marked N C Connect the ground ...

Страница 7: ...crews on the cover 5 11 Connect the grounding wire 9 Encase the packing onto the wire set and the grounding wire Reposition the packing to the connector 10 Connect the and the LED wire to the CBM wire set including the sensor wire ...

Страница 8: ...on from the center line is 2cm If it has to be deviated for more than 2cm due to the restriciton on site Please ensure the flexible tube would not detach or bend A detached or bent flexible tube may result in Abnormal air volume or air speed Remark 6 13 Install the dryer body under the counter Installation Recommended Deck Thickness 10 30mm 0 39 1 18 ...

Страница 9: ...over Do not flush with water Heater Element Switch ON OFF Warm Air Speed Adjustment SW FOR HEATER VR FOR AIR SPEED Sensor Range Adjustment VR FOR SENSOR 1 Switch off the power remove the cover screws and the cover 2 Use a small Philips head screwdriver or a plastic flat blade probe to turn the VR shaft Clockwise CW to increase power to maximum CCW to reduce power as needed 1 Switch off the power r...

Страница 10: ... sensor only sees close range objects The dryer only blows cold air during a full cycle First ensure that the breaker supplying the dryer is operational If it is disconnect the power and remove the dryer cover Replace the CBM and the IR sensor module Take suitable precautions to avoid shock hazard Reconnect the power and check for voltage at the terminal block Disconnect the power Remove the dryer...

Страница 11: ...4 6 7 8 5 Diagram 9 15 16 17 18 19 20 32 34 21 22 23 24 25 26 27 28 29 30 42 41 40 39 38 37 36 35 10 11 12 13 14 9 Parts inside of spout 31 3 2 1 33 ...

Страница 12: ...rd Module Blower mounting bracket Blower housing Below Motor rubber Below Motor Heater assembly Motor rubber Upper Blower housing Upper Cover Security hex screw 2 reqd Filter assembly Packing for wire assembly of sensor grounding wire Sensor wire Nylon hole bushing Base plate Grounding Screw Insulation Mylar Cable clamp Grounding wire Description 39 Cable clamp EU 40 Terminal block 41 Cable Protec...

Страница 13: ......

Отзывы: