Drucker Diagnostics Owl Manor HORIZON 24 Flex Скачать руководство пользователя страница 1

Laboratory Centrifuge

Model HORIZON 24 Flex Operator’s Manual

P/N 03-0-0002-0143

Rev. C

MODEL HORIZON 24 FLEX

Содержание Owl Manor HORIZON 24 Flex

Страница 1: ...Laboratory Centrifuge Model HORIZON 24 Flex Operator s Manual P N 03 0 0002 0143 Rev C MODEL HORIZON 24 FLEX...

Страница 2: ...7 Operation 7 Guide to Balanced Centrifuge Loads 8 Control Panel Functions Time Adjustment and Timer Operation 9 Speed Adjustment 9 Starting and Stopping a Run 9 Unlocking the Lid 9 Imbalance Detectio...

Страница 3: ...f tubes Cycle settings can be changed to accommodate custom setting WARRANTY Drucker Diagnostics warranties that this centrifuge is free from defects in workmanship and parts for 2 years See the next...

Страница 4: ...minutes 1 Weight 39 lbs Ambient Temperature During Operation 16 o C 35 o C Maximum Relative Air Humidity 90 Power Watts 280 Voltage Volts 95 to 235 Frequency Hz 50 60 Specifications General Specifica...

Страница 5: ...ol Panel see below Cabinet Up Down RPM Change Buttons Running Indicator Light Latched Indicator Light Unlocked Indicator Light RPM Display Open Stop Button Start Button Up Down Time Change Buttons Tim...

Страница 6: ...atched properly The centrifuge will not run unless the lid is latched properly and the LATCHED indicator light is illuminated 8 Use the up arrow button next to the RPM display to set the speed to full...

Страница 7: ...nd the rotor will decelerate to a complete stop 8 The UNLOCKED indicator light will illuminate the lid light will flash and the locking mechanism will disengage allowing entry into the rotor chamber I...

Страница 8: ...r a device and a counterbalance Please refer to device I F U for proper use of the counterbalance 1 device Load the opposing bucket with a counter balance 2 devices Place the two devices in opposite b...

Страница 9: ...lid switch closed press the START button to begin a run Press the OPEN STOP button at any time during a run to terminate it Unlocking the Lid The lid is unlocked whenever the red UNLOCKED indicator li...

Страница 10: ...ly remove the bucket Properly dispose of the sample and tube fragments and thoroughly clean both the inside and outside of the bucket Insert a new tube cushion if necessary and replace the bucket in t...

Страница 11: ...ERROR SPEED The centrifuge cannot reach full speed due to a problem with the rotor an inadequate power supply or other electrical problems Press the OPEN STOP button to cancel the error and then check...

Страница 12: ...l remain locked If the knob is accidentally moved and this situation should occur rotate the knob fully clockwise to its stop position and the centrifuge will resume operation Emergency Rotor Chamber...

Страница 13: ...nd recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more...