4. TECHNICAL SPECIFICATIONS 

 

CHARACTERISTICS 

VIP

4

Air lubrication panel

 

Power supply voltage 

24 V dc 

110 V ac  

Absorbed power 

10 W 

Air supply pressure 

5 - 8 bar 

Output signals  

Remote alarm contact: max. 250 V 1 A  NO/NC  

Working temperature 

-5 - +55 °C 

Working humidity 

90% max. 

Protection class 

IP-44 

Admissible lubricants 

Oil 

Oil viscosity at working temp. 

32 - 220 cSt 

Conservation temperature  

-20 - +65 °C 

 

WARNING:

 DO NOT supply the machine with voltages or pressures other than those indicated on the specification plate. 

 

 

5. DESCRIPTION OF COMPONENTS 

 

Central VIP

4

Air Unit 

The central unit of the lubrication system is composed of the three elements: 

 

Tank

, made of transparent plastic material, compatible with lubricants on the market. 

 

an

 air control system

 composed of a pressure regulator, applied laterally, and a solenoid valve, which can block the air flow. 

 

the 

VIP

4

Air panel

 manages and controls the entire lubrication process: the time intervals, the lubrication flow rate, the air 

pressure and the oil level. In addition it provides for priming cycles (air venting). 

 

Pneumatic Mini-pump 

The mini-pumps employed are particularly small and are installed on the mixer bases. They can be fitted with a range of spacers 
which serve to vary the flow rate. The following table details how to recognize these and indicates the relative part numbers. To 
change the spacers proceed as follows: 
 
1.

 

Unscrew and remove the brass cap (A). 

2.

 

Rotate shaft (B) until the hole (C) aligns with the relative slot. 

3.

 

Insert a Ø2 mm tommy bar in hole (C). 

4.

 

Unscrew hex. nut (D) using a 5,5 mm spanner. 

5.

 

Slide off the spacer (E) and replace it with the required one. 

6.

 

Replace and fully tighten nut (D), remove the tommy bar and replace cap (A). 

N° OF NOTCHES 

FLOW RATE 

(mm

3

/cycle) 

SPACER 

PART NUMBER 

30 

3233188 

15 

3233191 

3233193 

Notches 

Содержание VIP4Air Series

Страница 1: ...NERAL DESCRIPTION 3 PRODUCT MACHINE IDENTIFICATION 4 TECHNICAL SPECIFICATIONS 5 MACHINE COMPONENTS 6 UNPACKING AND INSTALLING THE MACHINE 7 INSTRUCTIONS FOR USE 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 OPERATING HAZARDS 15 PRECAUTIONS 16 WARRANTY INFORMATION 17 DECLARATION OF COMPLIANCE WITH STANDARDS 18 DROPSA LO...

Страница 2: ...uate for the location and the use of the panel both during its operation and during maintenance operations The panel and any accessories mounted on it should be carefully checked immediately on receipt and in the event of any discrepancy or complaint the Dropsa SpA Sales department should be contacted without delay Dropsa SpA declines to accept any responsibility for injuries to persons or damage ...

Страница 3: ...ly and a solenoid valve which can block the air flow the VIP4Air panel manages and controls the entire lubrication process the time intervals the lubrication flow rate the air pressure and the oil level In addition it provides for priming cycles air venting Pneumatic Mini pump The mini pumps employed are particularly small and are installed on the mixer bases They can be fitted with a range of spa...

Страница 4: ...cal connection completely integrated into the mixer base with the VIP4Air panel mounted on the central unit Where an anomaly occurs this is detected by the central unit which signals the error The functioning is also indicated by an LED mounted on the base itself When the VIP4Air starts a lubrication cycle the LED located on the mixer base illuminates ON until the end of the lubrication cycle Duri...

Страница 5: ...es for Ø6 mm bolts 6 3 MOUNTING THE MINI PUMPS ON THE MIXER BASES for replacement or augmenting The mini pumps are mounted on the mixer bases utilizing two securing screws Particular attention should be paid to the correct positioning of the o rings between the mini pump and the mixer base see diagram below 6 4 MOUNTING THE DOSER ASSEMBLY ON THE PUMP for replacement or augmenting To install a new ...

Страница 6: ...ns Note The female connector is purchased separately see Accessories N B After all connections have been completed ensure the tubing and cables are protected from impacts and are suitably secured 7 INSTRUCTIONS FOR USE 7 1 STARTING THE VIP4Air PANEL Before using the VIP4Air panel it is necessary to carry out some preliminary checks check the integrity of the equipment check that the electrical and...

Страница 7: ...he pump The range of regulation is 0 0 9 9 seconds Enter the desired values using the and keys 1 5 s Pause cycle Interval of time between one lubrication cycle and the next The count commences when the delivery of lubricant is confirmed Range of regulation is 00 00 99 59 minutes Enter the desired values using the and keys User discretion Inversion of solenoid command Relay function 1 for NC 0 for ...

Страница 8: ... out Priming verifying the delivery of lubricant at the outlet o Flow sensor defective Check the sensor electrical connections or replace it o Check the oil level in the tank o Check the pressure on the display and regulate it on the external reducer To facilitate the operation press and hold down the key to freeze the air pressure display The alarm depends on the value entered during set up o Che...

Страница 9: ...isconnected before undertaking any maintenance tasks 10 DISPOSAL During the maintenance of the machine or in the event of its being scrapped do not discard polluting components in the environment Refer to local regulations for their correct disposal At the time of final disposal of the machine it is necessary to destroy the identification plate and all other documentation 11 ORDERING INFORMATION V...

Страница 10: ...10 15 DIMENSIONS Number of elements Height A mm Weight Kg 1 331 3 8 2 359 4 3 3 387 4 8 4 415 5 3 5 448 5 8 6 471 6 3 7 499 6 8 8 527 7 3 Tube Air input Tube Ø 6 ...

Страница 11: ... out the replacement of the mini pumps empty the tank of lubricant 15 CONTRAINDICATIONS The VIP4Air panel does not have any particular contraindications except for the following points The operator coming into contact with fluid due to breakage opening of supply tubing The operator must be furnished with suitable personal protection clothing equipment Abnormal posture Take note of the indications ...

Страница 12: ...IP4AIR è conforme alle condizioni previste dalle Direttive CEE has been constructed in conformity with the Directives Of The Council Of The European Community on the standardization of the legislations of member states a été construite en conformité avec les Directives Du Conseil Des Communautes Europeennes Entsprechend den Richtlinien des Rates Der Europäischen Union für die Standarisierung der L...

Страница 13: ...uk dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerling Hts Mi Us USA Tel 1 586 566 1540 Fax 1 586 566 1541 E mail salesusa dropsa com Dropsa Lubrication Systems Nr 8 Dongxing Road Songjiang Industrial Zone Shanghai Co Ltd Tel 86 021 67740275 Fax 86 021 ...

Отзывы: