8. TROUBLESHOOTING
The following diagnostic table indicates the main anomalies which may be encountered, the probable causes
and possible solutions.
If you cannot solve the problem, do not attempt to disassemble the unit, but
contact the Engineering Department of DROPSA S.p.A.
8.1 PUMP DIAGNOSTICS (MANUAL AND AUTOMATIC
SMART2
)
ANOMALY
PROBABLE CAUSE
SOLUTION
Pump does not deliver
lubricant.
Pump does not deliver the
fixed amount of lubricant
•
Pump draws off air
because the reservoir
is empty.
→
Refill the reservoir and vent air
from the system.
•
Loosened inner
fittings.
→
Retighten all the fittings.
Be sure there are no
Leakages.
•
Wear of the pump.
→
Replace the pump.
Pump delivers oil at an
improper pressure
•
Wrong calibration of
the by-pass valve.
→
Install a manometer to adjust
by-pass at the proper
pressure.
The system stays in
pressure at the end of the
lube cycle
•
Vent valve damaged
or dirty.
→
Inspect and clean the valve.
Replace it, if necessary.
8.2
VIP2004 CONTROLLER
ALARMS (AUTOMATIC
SMART2
)
When an alarm occurs, an external signal is ON. The display will show one of the following alarms for two
seconds:
ALARM 01 - TIMER FAULT
Internal process error during
lube by timer
.
ALARM 02 - PX VENT FAILED
At the beginning of
lube by PS
: it was detected
that the system has not vented air.
ALARM 04 PS - PRESSURE ALARM
During
lube by PS
, it was detected that the
system never goes in pressure.
ALARM 06 PS - PRESSURE LOSS
During
lube by PS
, even though the pump is
operating, the system loses pressure.
ALARM 08 PS - GENERAL FAULT
Internal process error during
lube by PS
.
ALARM 09 SEP - CYCLE TIMEOUT
During
lube by SEP
: the sensor cannot detect
one or all the changes of position of the piston.
ALARM 10 SEP - GENERAL FAULT
Internal process error during
lube by SEP.
ALARM 11 - LOW LEVEL
The Samba Level Sensor detected low level.
Refill the reservoir.
8.3 RESTART/RESET the system
Once one of the above alarm status occurs, another display will be shown:
For example:
There are two ways to restore machine operating:
⇒
By pressing
setup
(left push-button), the system will enter the setup session to modify, at any rate,
parameters and re-start the machine.
⇒
By pressing
reset
for two seconds (right push-button or RESET button), the system will be reset and
the machine will be re-initialized and will operate according to the last saved data setup.
WARNING: This unit can be opened and repaired by Dropsa personnel only
ALARM 11
setup reset