11
7.4.4 Operative
parameters
Parameter
Description
Operative range
Dropsa setting
Timer*
A timer defines lube duration
00m01s ÷ 4m59s
PS
Lube starts when system is in
pressure (Pressure is
monitored by a pressure-
switch)
LUBE Type
SEP
A proximity sensor detects
the changes of position of the
piston: after three changes a
lube cycle is completed
10s ÷ 99 min.
00m:10s
Timer*
A timer defines standby
duration (system idle)
01m00s ÷ 999h59m59s
06m:00s
Pulse
A pulse register defines
standby duration (system idle)
1i ÷ 9,999,999i
100i
STANDBY
Type
Both
Standby duration (system
idle) is defined by both
standby timers (timer and
pulse), whichever occurs first
See Standby
Timer and pulse
06m:00s
100i
DELAY TIME
(FOR PS ONLY)
A timer defines the duration of
PUMP ON (time lag for pump
OFF) once the system goes in
pressure
01s ÷ 99 min.
00m:02s
LUBE Cycles
Number of lube cycles to be
carried out by the system
01÷ 999
1
PRELUBE cycles
Number of prelube cycles,
which will be carried out
before the lube cycles
1÷ 999
0
WAIT Time
A timer defines the duration
of a
pause time
between each
lube process.
ONLY for ‘LUBE type: SEP’:
Set 00m00s for continuous
service
01s ÷ 16m39s
00m:05s
START IN LUBRIC.
START MODE
It allows to choose how to
start the working session
START IN STANDBY
START IN LUBRIC.
Norm. Open
Alarm
It allows to choose the type of
alarm electric contact
Norm. Close
Norm. Close
Date & Time
It allows to enable/disable
Date & time display and setup
Enabled/Disabled Enabled
Day
It allows to set the day
1-31
1
Month
It allows to set the month
1-12 1
Year
It allows to set the year
2000÷2099 2004
Hour
It allows to set the hour
0-23 0
Minute
It allows to set the minutes
00-59 00
*Default setting: Lube type: Timer; Standby Type: Timer; Date & Time: Enabled
NOTICE: When Date and Time are enabled, in order to avoid controller malfunctioning, it is
recommended to set
day
,
month
and
year
in accordance with the calendar.
7.5
I-R communication
Controller VIP2004
is provided with an I-R port for infra-red communication via special I-R device and Dropsa
software to be installed on your PC. This innovative system will allow you to
remotely
manage (1÷1.5 m – 39 ÷
60 in.-) two important operations:
-
Lube status reading->
reading of the machine data on your PC: lube parameters, date, time and
logs;
-
Machine programming
-> setup of the machine data from your PC: lube parameters, date and time.
The
I-R
communication system (Dropsa software included)
is furnishable by Dropsa on demand.