DROPSA MiQueL Скачать руководство пользователя страница 7

 

Use a screwdriver to turn the air regulation pin anticlockwise to increase the flow rate or clockwise to decrease the 

flow rate, until the desired spray is obtained, normally the adjustment is made by max 3 revs. 

 

 

 

8. TROUBLESHOOTING 

 

 

 

A diagnostics table is provided below that indicates the main anomalies, the probable causes and the possible solutions. 

If you were not able to solve the problem after consulting the diagnostics table, do not try to find the fault by 

disassembling machine parts but contact the Dropsa technical office and report the discovered anomalies, with a detailed 

description. 

 

DIAGNOSTICS TABLE 

ANOMALY 

CAUSE 

SOLUTION 

Lubrication does not take place 

activating the solenoid valve. 

Solenoid valve broken. 

Replace the solenoid valve. 

The air supply pressure is below 4 bar. 

Increase the supply pressure up to a 

minimum of 4 bar. 

The lubricant exits irregularly and 

with large air bubbles visible in the 

Ø3 oil pipe. 

Lubricant below the minimum level in 

the tank. 

Top up the tank with new lubricant. 

The Ø3 oil pipe is not perfectly engaged 

in the module push-in. 

Insert the pipe, making sure to insert it 

to the end. 

 

 

 

9. MAINTENANCE PROCEDURE 

 

The units were designed and built in order to minimise maintenance requirements. 

To simplify maintenance, it is recommended to install them in an easy to reach position.  

(see section 6.2). 

 

Periodically check the pipe joints to detect any leaks. 

 

Periodically check the oil level and fill it if necessary through the loading cap. 

 

Always keep the modules clean to be able to quickly detect any leaks. 

The machine does not require any special equipment for any control and/or maintenance activity. It is recommended to 

use tools and personal protective devices suitable for use in ref. to leg. decree 81/2008, and that are in good condition 

according to current regulations to prevent damage to people or machine parts. 

 

10. DISPOSAL

 

 

During machine maintenance, or if it is demolished, do not dispose of the polluting parts in an improper manner. Refer to 

the local regulations for their correct disposal. When demolishing the machine, the identification plate and all other 

documents must be destroyed. 

ATTENTION! 

Do not over unscrew the air regulation pin as it may come free of its housing. 

  

 

 

ATTENTION! The unit may only be opened and repaired by authorised Dropsa personnel. 

  

 

ATTENTION! Make sure that the pneumatic power supply is disconnected before carrying out any 

maintenance work.

 

 

Содержание MiQueL

Страница 1: ...RUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 PRECAUTIONS 15 OPERATING HAZARDS Manual drawn up in accordance wi...

Страница 2: ...operator The outward oil and air flow can be managed independently between the different modules using a mini solenoid valve i version only or a pneumatic valve NO EV version only that activates the c...

Страница 3: ...ting pressure in bar V viscosity Engler at operating temperature Lubricating oil 10cSt 100cSt Protection grade of module i Standard IP 00 On request special IP 65 Protection grade of reservoir IP 65 P...

Страница 4: ...l Pressure switch optional Pressure gauge Loading cap with filter Device to remove 3 tube optional Visible level Modular element outlets Air inlet Mounting brackets Tank Minimum electric level Mountin...

Страница 5: ...tions 6 3 PNEUMATIC CONNECTIONS Before making the connection check that the valve for the main air the manual sliding valve and the check valves air and oil are closed Make sure that the inlet pressur...

Страница 6: ...s at the operating temperature 7 1 USE Open the manual cursor valve Press the start button on the machine to which the unit is connected or start it Check that the solenoid valves on the elements are...

Страница 7: ...sert it to the end 9 MAINTENANCE PROCEDURE The units were designed and built in order to minimise maintenance requirements To simplify maintenance it is recommended to install them in an easy to reach...

Страница 8: ...3135567 8 3135528 3135568 MiQueL BASE i Air Oil modular minimal system without compensation valve with solenoid valve for independent control 1 3135531 3135571 2 3135532 3135572 3 3135533 3135573 4 31...

Страница 9: ...odular element 3132768 Kit FULL cone coaxial nozzle 3133559 AIR inlet solenoid valve kit 3133455 FULL cone coaxial nozzle 0020694 Pressure gauge for module AIR outlet i 3133558 65 FLAT jet coaxial noz...

Страница 10: ...10 12 DIMENSIONS...

Страница 11: ...on the machine before disconnecting it from the electrical power supply and making sure that no one can reconnect it during the operation All the installed equipment electric and electronic tanks and...

Страница 12: ...maintenance activities Electrocution This can only occur in the case of serious user incompetence but the user must be qualified Unsuitable postures The correct dimensions and installation methods are...

Отзывы: