6. UNPACKING AND INSTALLING 

 

6.1 UNPACKING  

Once the suitable location for installation has been identified, open the package and remove the unit. 

Check that it was not damaged during transport or storage. 

The packaging material does not require special disposal precautions as it is not in any way dangerous or polluting. 

 

6.2 INSTALLATION  

Allow a sufficient amount of space for installation, leaving a minimum perimetric space of 100 mm (3.93 in.). 

Install the unit at “shoulder height” to prevent abnormal positions or the possibility of impacts. 

Use the brackets with the holes (see chap. 12) to fix the unit properly. It is also possible to disassemble the brackets from 

their current position and reassemble them in the prepared threaded holes for side or corner installation. 

It is prohibited to use the unit if submersed in fluids or in a particularly aggressive or explosive/inflammable environment 

if not previously prepared for that purpose by the supplier. 

Use safety gloves or glasses as specified in the safety sheet for the lubricant. 

Do not use aggressive lubricants with NBR gaskets. In the case of doubt, contact the Dropsa SpA technical office to receive 

a detailed card about the recommended oils. 

Do not ignore the hazards to health and comply with the health regulations. 

 

6.3 PNEUMATIC CONNECTIONS 

Before making the connection, check that the valve for the main air, the manual sliding valve and the check valves (air and 

oil) are closed. Make sure that the inlet pressure does not exceed 7bar. 

Use fittings and pipes that are suitable for the operating pressures, push-in connection for Ø10 mm pipe. 

For 

"NO-EV"

 version use suitable pipe for operating pressure, push-in for Ø4 mm pipe. 

 

 

 

6.4 ELECTRIC CONNECTIONS 

Connect the minimum level as shown in the diagram 

below  

and indicated on the plate on the reservoir. 

 

 

 

 

 

Connect the (optional) “NO” pressure switch, precalibrated to 6 bar, by passing the cables from the protective cover using 

a 6.3 mm fasten. 

 

6.5 FILLING THE TANK 

Make sure there is no residual pressure in the tank (pressure gauge indicator: “0”). 

The oil is transferred to the tank through the loading cap with a filter. 

The “maximum” sign on the filling indicator must never be exceeded. 

 

6.6 AIR/OIL HYDRAULIC CONNECTIONS TO THE LUBRICATION NOZZLE 

Using coaxial pipes, connect the Ø3mm pipe 

  to the oil outlet push-in 

  on the module, slide the Ø6mm tube 

 

outside the Ø3mm tube until connect it to the air outlet push-in 

 

 

 

 

 

 

 

 

 

 

Then connect the same coaxial pipes to the lubrication nozzle push-in as shown below: 

1.

 

Insert the Ø6 air pipe in the push-in on the nozzle connection. 

 

ATTENTION! Always install a regulator filter with condensate recovery on the air inlet. Any unfiltered deposits or 

sediments could irreparably damage the product. 

  

 

AIR 

AIR 

OIL 

AIR 

OIL 

Содержание MiQueL

Страница 1: ...RUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 PRECAUTIONS 15 OPERATING HAZARDS Manual drawn up in accordance wi...

Страница 2: ...operator The outward oil and air flow can be managed independently between the different modules using a mini solenoid valve i version only or a pneumatic valve NO EV version only that activates the c...

Страница 3: ...ting pressure in bar V viscosity Engler at operating temperature Lubricating oil 10cSt 100cSt Protection grade of module i Standard IP 00 On request special IP 65 Protection grade of reservoir IP 65 P...

Страница 4: ...l Pressure switch optional Pressure gauge Loading cap with filter Device to remove 3 tube optional Visible level Modular element outlets Air inlet Mounting brackets Tank Minimum electric level Mountin...

Страница 5: ...tions 6 3 PNEUMATIC CONNECTIONS Before making the connection check that the valve for the main air the manual sliding valve and the check valves air and oil are closed Make sure that the inlet pressur...

Страница 6: ...s at the operating temperature 7 1 USE Open the manual cursor valve Press the start button on the machine to which the unit is connected or start it Check that the solenoid valves on the elements are...

Страница 7: ...sert it to the end 9 MAINTENANCE PROCEDURE The units were designed and built in order to minimise maintenance requirements To simplify maintenance it is recommended to install them in an easy to reach...

Страница 8: ...3135567 8 3135528 3135568 MiQueL BASE i Air Oil modular minimal system without compensation valve with solenoid valve for independent control 1 3135531 3135571 2 3135532 3135572 3 3135533 3135573 4 31...

Страница 9: ...odular element 3132768 Kit FULL cone coaxial nozzle 3133559 AIR inlet solenoid valve kit 3133455 FULL cone coaxial nozzle 0020694 Pressure gauge for module AIR outlet i 3133558 65 FLAT jet coaxial noz...

Страница 10: ...10 12 DIMENSIONS...

Страница 11: ...on the machine before disconnecting it from the electrical power supply and making sure that no one can reconnect it during the operation All the installed equipment electric and electronic tanks and...

Страница 12: ...maintenance activities Electrocution This can only occur in the case of serious user incompetence but the user must be qualified Unsuitable postures The correct dimensions and installation methods are...

Отзывы: