background image

7. OPERATING INSTRUCTIONS 

 

7.1 STARTING THE PUMP 

Before using the pump, a few preliminary checks must be performed: 

 

 

Check the integrity of the power supply cable and the unit prior to use. 

 

If there is damage to the power supply cable or the unit, do not start operations! 

 

Replace the damaged power supply cable with a new one. 

 

The unit may only be opened and repaired by specialized personnel. 

 

In order to prevent the danger of electrocution due to direct or indirect contact with live parts, the electric power supply line 
must be suitably protected by a specific differential magnetothermic switch with a triggering threshold of 0.03 Ampere and

 

max triggering time of 1 second.  

 

 
 

 

 

It is prohibited to use the pump if submersed in fluids or in a particularly aggressive or explosive/inflammable environment if 
not previously prepared for that purpose by the supplier. 

 

Use safety gloves or glasses as specified in the safety sheet for the lubricating oil 

 

DO NOT use aggressive lubricants with NBR gaskets. In the case of doubt, contact the Dropsa SpA technical office to receive a 
detailed card about the recommended oils. 

 

Do not ignore the hazards to health and comply with the health regulations.

 

 
 
 

 

 

 

 

Check the integrity of the pump 

 

Check that the pump is at the operating temperature and that there are no air bubbles in the pipes. 

 

Check that the electric connection was carried out correctly. 

 

Check the connection of the level and the pressure switch, if necessary, to the control panel. 

 

Once  the  pump  has  started,  check  the  direction  of  rotation  of  the  electric  motor:  if  it  rotates  backward,  reconnect  it  as 
shown in the wiring diagram provided with the motor. 

 

7.2 INSTRUCTIONS FOR USE 

1)

 

Press the start button on the machine to which the pump is connected or start it; 

2)

 

Check that the pump starts; 

3)

 

To change the pressure value, turn the adjustment screw (see Chap. 5). Turn it clockwise to increase the pressure or 
counterclockwise to decrease it; 

4)

 

Check that the machine lubrication is suitable (if there are doubts about correct operation, the Dropsa SpA technical office 
can be contacted to request the inspection procedure). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The cut-off power of the switch must be = 10 kV and the rated current= 4 A 

 

ATTENTION

:

  All  components  must  be  ground  connected.  This  applies  both  to  electric  components  as  well  as  to  control 

devices. For this purpose, make sure that the ground wire is directly connected. For safety reasons, the ground conductor 
must be approx. 100 mm longer than the phase conductors. If the cable is accidentally disconnected, the ground terminal 
must be the last to be disconnected.

 

 

Содержание 3905000

Страница 1: ...ACTERISTICS 5 COMPONENTS 6 UNPACKING AND INSTALLING 7 OPERATING INSTRUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION...

Страница 2: ...versatility when used with press lubrication systems machine tools reducers guides chains etc The DRAGON X pump has a built in release valve and can be used in the following types of systems Lubricati...

Страница 3: ...el connector optical floating switch DIN 43650 Float Level output signal Clean contact 50V max voltage 40 W max power SPDT Contact Pressure switch Contact closed in the case of max calibration pressur...

Страница 4: ...4 4 1 HYDRAULIC SYSTEM The only connection to make is to connect the pump to the point to lubricate or to the metering valves Fig 2 Hydraulic diagram with check valve Fig 1 Hydraulic diagram...

Страница 5: ...mounting suitable space must be provided see the installation diagram to prevent abnormal positions or the possibility of impacts fixing holes are provided on the plate see Para 12 Then the pump must...

Страница 6: ...the level is off see the image below 4 Turn the screw in opposite way until the green led is on At the end of this procedure the level is correctly set It is possible to re do the calibration followi...

Страница 7: ...ions Check the integrity of the pump Check that the pump is at the operating temperature and that there are no air bubbles in the pipes Check that the electric connection was carried out correctly Che...

Страница 8: ...e by pass valve Replace the pump Tighten the adjustment screw until oil comes out of the delivery pipe Replace the by pass valve Connect a pipe that is approx 30 cm long to the pump outlet with a pres...

Страница 9: ...an improper manner Refer to the local regulations for their correct disposal When demolishing the machine the identification plate and all other documents must be destroyed 11 ORDER INFORMATION 11 1...

Страница 10: ...SENSOR LEVEL For the 3L tank 1639201 For the 6L tank 1639202 FLOATING LEVEL INDICATOR For the 3L tank 3133627 For the 6L tank 3133628 DISTRIBUTOR BLOCK 1525370 TANK 3 L 6770033 6 L 6770006 PRESSURE G...