background image

 

 

A comparison table is provided between the classification of NLGI lubricants (National 

Lubricating Grease Institute) and the ASTM classification (American Society for Testing 

and Materials) for greases for the values that concern the pump. 

 

For further information about the technical specifications and the safety measures to 

adopt, refer to the product safety sheet (Directive 93/112/EEC) relative to the type of 

lubricant selected and supplied by the manufacturer. 

 

15. 

CONTRAINDICATIONS FOR USE

 

 

The check on compliance with the essential safety requirements and with the stipulations indicated in the machine directives 

are to be carried out by means of compiling the checklists already made available and contained in the 

technical file.

 

Three types of lists were used: 

 

 

list of dangers (section from EN 414 relating to EN 292) 

 

Application of the essential safety requirements  (Machine Dir. – 06/42) 

 

electrical safety stipulations (EN 60204-1) 

 

See below a list of dangers which have not been completely eliminated, but are considered acceptable: 

 

 

During assembly/maintenance it is possible that there may be an oil splash (consequently this operation must be carried out 

using appropriate individual protective devices); 

 

contact with oil -> see instructions for using appropriate individual protective devices DPI; 

 

Use of an inappropriate lubricant -> fluid characteristics indicated both on the pump and in the manual (

if in doubt consult 

our Technical Office);

 

 

protection against direct and indirect contact must be provided by the user; 

 

whenever the cover is opened for an intervention resealing the catch is essential; 

 

The pump’s working logic requires it to operate at all times, so it is necessary to pay attention to the electric connection. If 

there is no current the customer’s machine can only be restarted following a reset while the lubrication pump can restart 

automatically. 

 

FLUIDS EXPLICITY NOT ALLOWED  

Fluid 

Fluid 

Lubricants with abrasive additives 

Lubricants with abrasive additives 

Lubricants with silicone based additives 

Lubricants with silicone based additives 

Petrol – solvents – inflammable liquids 

Petrol – solvents – inflammable liquids 

Corrosive products 

Corrosive products 

Water 

Water 

Food substances 

Food substances 

 

* For more detailed information regarding product compatibility with particular fluids, contact the Dropsa S.p.A. technical office

 

 
 

NLGI 

ASTM 

000 

445 – 475 

00 

400 – 430 

355 – 385 

310 – 340 

265 – 295 

Содержание 2451011

Страница 1: ...NENTS 6 UNPACKING AND INSTALLING 7 OPERATING INSTRUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 PRECAUTIONS 15...

Страница 2: ...type of distribution can be altered This construction technique is essentially based on the following modules Electric motor Pump body with integrated reducer Two pumping elements Reservoir Valves and...

Страница 3: ...Kg reservoir 100 Kg ELECTRICAL CHARACTERISTICS Motor power supply 230 400V 5 50Hz 280 480V 5 60Hz Rated motor power 0 75 Kw Motor degree of protection IP 55 Minimum level Laser grease floating Oil Ma...

Страница 4: ...sente di garantire un ottima tenuta del sistema alle alte pressioni di funzionamento pressione max di 400 bar Pumping elements are mounted on the pump casing without the need to disconnect the line pi...

Страница 5: ...vel reserve and the maximum level which allows the automatic refilling of the tank to be halted For connections see paragraph 7 3 4 5 1 3 3 Maximum visual floating level for oil grease The phase that...

Страница 6: ...ds or in a particularly aggressive or explosive inflammable environment if not previously prepared for that purpose by the supplier Use safety gloves or glasses as specified in the safety sheet for th...

Страница 7: ...e for calibrating the laser probe 24V cc Out 4 20mA 2 NO 4 thresholds The laser probe possesses a representative and programming display mounted on board It is possible to operate in analogue mode wit...

Страница 8: ...3190489 No signal indicating minimum level when there is no lubricant in the tank Incorrect adjustment of minimum level Check the correct functioning of the level probe in the following way Dismantle...

Страница 9: ...74 56 UL and NEMA standard 230 460V 60 Hz On request 80 Pneumatic motor 3301539 95 Inverter NOT PRESENT 0 4 3 Valve Electromagnetic 24 V DC 0083550 1 4 2 Electromagnetic inverter 24 V DC 0083560 2 4 2...

Страница 10: ...TS Spare part description Variant P No Motors 3Ph 0 75 Kw IE3 230 400Y 50Hz 280 480Y 60Hz 3301081 3Ph UL and CSA 0 75 Kw IE3 230 400Y 50Hz 280 480Y 60Hz 3301528 Reducer i 40 3301608 Maximum mechanical...

Страница 11: ...12 DIMENSIONS 30 Kg 100 Kg mm in mm in A 533 5 21 983 38 7 B 1084 42 67 1534 60 39 C 984 38 74 1434 56 45 D 313 12 32 413 16 25...

Страница 12: ...lectrical power supply and making sure that no one can reconnect it during the operation All the installed equipment electric and electronic tanks and basic structures must be connected to the ground...

Страница 13: ...splash consequently this operation must be carried out using appropriate individual protective devices contact with oil see instructions for using appropriate individual protective devices DPI Use of...