background image

 

 

12. DIMENSIONS 
 

 

30 Kg 

100 Kg 

mm 

in 

mm 

in 

533.5 

21 

983 

38.7 

1084 

42.67 

1534 

60.39 

984 

38.74 

1434 

56.45 

313 

12.32 

413 

16.25 

 

Содержание 2451011

Страница 1: ...NENTS 6 UNPACKING AND INSTALLING 7 OPERATING INSTRUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 PRECAUTIONS 15...

Страница 2: ...type of distribution can be altered This construction technique is essentially based on the following modules Electric motor Pump body with integrated reducer Two pumping elements Reservoir Valves and...

Страница 3: ...Kg reservoir 100 Kg ELECTRICAL CHARACTERISTICS Motor power supply 230 400V 5 50Hz 280 480V 5 60Hz Rated motor power 0 75 Kw Motor degree of protection IP 55 Minimum level Laser grease floating Oil Ma...

Страница 4: ...sente di garantire un ottima tenuta del sistema alle alte pressioni di funzionamento pressione max di 400 bar Pumping elements are mounted on the pump casing without the need to disconnect the line pi...

Страница 5: ...vel reserve and the maximum level which allows the automatic refilling of the tank to be halted For connections see paragraph 7 3 4 5 1 3 3 Maximum visual floating level for oil grease The phase that...

Страница 6: ...ds or in a particularly aggressive or explosive inflammable environment if not previously prepared for that purpose by the supplier Use safety gloves or glasses as specified in the safety sheet for th...

Страница 7: ...e for calibrating the laser probe 24V cc Out 4 20mA 2 NO 4 thresholds The laser probe possesses a representative and programming display mounted on board It is possible to operate in analogue mode wit...

Страница 8: ...3190489 No signal indicating minimum level when there is no lubricant in the tank Incorrect adjustment of minimum level Check the correct functioning of the level probe in the following way Dismantle...

Страница 9: ...74 56 UL and NEMA standard 230 460V 60 Hz On request 80 Pneumatic motor 3301539 95 Inverter NOT PRESENT 0 4 3 Valve Electromagnetic 24 V DC 0083550 1 4 2 Electromagnetic inverter 24 V DC 0083560 2 4 2...

Страница 10: ...TS Spare part description Variant P No Motors 3Ph 0 75 Kw IE3 230 400Y 50Hz 280 480Y 60Hz 3301081 3Ph UL and CSA 0 75 Kw IE3 230 400Y 50Hz 280 480Y 60Hz 3301528 Reducer i 40 3301608 Maximum mechanical...

Страница 11: ...12 DIMENSIONS 30 Kg 100 Kg mm in mm in A 533 5 21 983 38 7 B 1084 42 67 1534 60 39 C 984 38 74 1434 56 45 D 313 12 32 413 16 25...

Страница 12: ...lectrical power supply and making sure that no one can reconnect it during the operation All the installed equipment electric and electronic tanks and basic structures must be connected to the ground...

Страница 13: ...splash consequently this operation must be carried out using appropriate individual protective devices contact with oil see instructions for using appropriate individual protective devices DPI Use of...

Отзывы: