8 Clearances to Combustible Material
The clearances shown in this section have been determined by test according to
procedures set out in safety standards ULC S627 (Canada), UL1482 (U.S.A.) and UL737
(U.S.A.). When the stove is installed so that its surfaces are at or beyond the minimum
clearances specified, combustible surfaces will not overheat under normal and even
abnormal operating conditions.
No part of the stove or flue pipe may be located closer to combustibles than the
minimum clearance figures given.
8.1 Location of the certification label
Since the information given on the certification label affixed to the appliance always
overrides the information published, in any other media (owner’s manual, catalogues,
flyers, magazines and/or web sites) it is important to refer to it in order to have a safe and
compliant installation. In addition, you will find information about your stove (model, serial
number, etc.). You can find the certification label on the back of the stove.