Rocket Installation and Operation Manual
28
If the above clearances are met, then the distances measured from the flue outlet
will be:
DISTANCES* FROM PIPE
CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA
USA
D
18" (457 mm)
17½" (445 mm)
E
26½" (673 mm)
26½" (673 mm)
F
18" (457 mm)
18" (457 mm)
DISTANCES* FROM PIPE
CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA
USA
D
12½" (298 mm)
12½" (298 mm)
E
26½" (673 mm)
26½" (673 mm)
F
18" (457 mm)
18" (457 mm)
*The pipe distances listed in this table refer to the distances obtained when the
stove is installed in accordance with the appliance clearances above mentioned.
However, you can install the stove at reduced clearances; follow the instructions in
Section 7.4: Reducing Wall and Ceiling Clearances Safely. Where they are followed,
the new distance of the pipe to combustible materials must be respected in the
appropriate certification of the pipe.
Clearances with ceiling (L) lowered to 68" (173 cm)
APPLIANCE CLEARANCES
(INSTALLATION WITH SINGLE
WALL PIPE CONNECTOR)
CANADA
USA
A
15½" (394 mm)
15" (381 mm)
B
18" (457 mm)
18" (457 mm)
C
12" (305 mm)
12" (305 mm)
K
48" (1220 mm)
48" (1220 mm)
L
68" (173 cm)
68" (173 cm)
APPLIANCE CLEARANCES
(INSTALLATION WITH DOUBLE
WALL PIPE CONNECTOR)
CANADA
USA
A
12" (305 mm)
12" (305 mm)
B
18" (457 mm)
18" (457 mm)
C
10" (254 mm)
10" (254 mm)
K
48" (1220 mm)
48" (1220 mm)
L
68" (173 cm)
68" (173 cm)
Note: These clearances are also valid for an alcove installation.
If the above clearances are met, then the distances measured from the flue outlet
will be:
DISTANCES* FROM PIPE
CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA
USA
D
18" (457 mm)
17½" (445 mm)
E
26½" (673 mm)
26½" (673 mm)
F
20" (508 mm)
20" (508 mm)
DISTANCES* FROM PIPE
CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA
USA
D
14½" (368 mm)
14½" (368 mm)
E
26½" (673 mm)
26½" (673 mm)
F
18" (457 mm)
18" (457 mm)
*The pipe distances listed in this table refer to the distances obtained when the
stove is installed in accordance with the appliance clearances above mentioned.
However, you can install the stove at reduced clearances; follow the instructions in
Section 7.4: Reducing Wall and Ceiling Clearances Safely. Where they are followed,
the new distance of the pipe to combustible materials must be respected in the
appropriate certification of the pipe.
Содержание Rocket DB03185
Страница 9: ...Rocket Installation and Operation Manual Rocket Installation and Operation Manual 9...
Страница 29: ...Rocket Installation and Operation Manual 29 Clearances to combustible materials and floor protection...
Страница 32: ...Rocket Installation and Operation Manual 32 Clearances for shield construction...
Страница 44: ...Rocket Installation and Operation Manual 44 Appendix 4 Exploded Diagram and Parts List...