Savannah Installation and Operation Manual
37
8.2.2 Factory-built Metal Chimneys in
mobile homes
For use in a mobile home, this stove is to
be connected to a 6” in diameter double
wall factory built chimney conforming to
CAN/UCL-S629, Standards for 650°C
Factory-built chimney. The total length of
the flue system should be at least 12 feet
including elbows, from the top of the
stove.
To maintain an effective vapour barrier,
insulation and waterproof at the chimney
and outside flue pipe, install a mobile
home roof flashing and seal it with
silicone.