Page 13
OPERATION MANUAL ECO-55 / ECO-55 ST
ENGLISH
6.5.8 VENTING SYSTEM
See the following section for recommandations on
maintaining the venting system.
6.5.9 GASKETS
When maintaining the heat exchanger channel and
the exhaust channel, make sure the gaskets on the
cleaning panels are in good condition. Replace them
if necessary.
SIL
IC
O
N
E
Inspect the door gasket. It is important to maintain
the door gasket in good condition. After a while, the
gasket will wear and compress.
If the stove door is not properly sealed, it will be
difficult to keep the door glass clean and combustion
gases may leak into the room.
Adjusting the door may then be required. If the door
adjustment is not sufficient, replace the door gasket
with a genuine part.
6.5.10 DOOR ADJUSTMENT
Remove the lock pin by pulling and turning with
pliers. Turn the handle counter clock wise one turn to
increase pressure.
E
Re-install the lock pin (spring pin) with a small
hammer.
Check the door seal by closing and locking the door
on a piece of paper. Check the entire door. Paper
should not slide easily. If the paper slips easily, adjust
the door.
6.5.9 DOOR SEAL VERIFICATION