Installation and Operation Requirements - Deco Alto
ENGLISH
3.1.2 With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada
USA
A
14 ½" (368 mm)
11" (279 mm)
B
23" (584 mm)
23" (584 mm)
C
12" (305 mm)
12" (305 mm)
L
77" (196 cm)
77" (196 cm)
Ve
Ho
L
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
USA
A
9" (229 mm)
9" (229 mm)
B
23" (584 mm)
23" (584 mm)
C
12" (305 mm)
12" (305 mm)
L
77" (196 cm)
77" (196 cm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
1
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES
1
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
D
18" (457 mm)
14 ½" (368 mm)
D
12 ¼" (311 mm)
12 ¼" (311 mm)
E
32 ½" (825 mm)
32 ½" (825 mm)
E
32 ¼" (819 mm)
32 ¼" (819 mm)
F
21 ¾" (552 mm)
21 ¾" (552 mm)
F
21 ½" (549 mm)
21 ½" (549 mm)
1
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.